Power & Gas Connection:
THE APPLIANCE MUST BE CONNECTED IN ACCORDANCE WITH CURRENT GAS &
ELECTRICAL RULES AND REGULATIONS. INSTALLATION IS TO BE DONE ONLY BY
AUTHORISED PERSONNEL.
Gas Connection
The gas settings are listed in the data label for both NG and ULPG. Kindly ensure the correct
nozzle injectors are used for the gas supply.
Before connecting the appliance to the gas network, make sure that the gas distribution
network complies with the details stated in the data label. This appliance must be installed
in compliance with relevant gas standards and / or codes of practice applicable.
The gas connection is via a G ½” male thread loose fitting which is located at the left rear
of the cooker.
Connect the adaptor to the appliance gas connection, and check if the seals between the
adaptor and gas connection are in place and in good connection. Gasket or washer is
required for sealing mechanism.
Adaptor must be fitted on gas connection to cooker prior to assembling other components.
For NG, connect the natural gas regulator with the integral test point by using approved
gas thread tape.
For ULPG, connect the ULPG test point by using approved gas thread tape. If the supplied
adaptor has a test point fitted, ULPG test point is not required.
Ensure the supply connection point, test point and natural gas regulator adjustment screw
(for NG installation) are accessible for testing and/or adjustment when the appliance is in
the installed position.
Adaptor with test point fitted
OR
Page 7
V 2.0