Installation & Operation Manual:
Automated Forklift Entryway Sanitizing System
_________________________________________________________________________________________________
21 |
P a g e
REFILLING THE SANITIZER:
If refilling the sanitizer container, you must remove and replace the safety feed insert.
Follow the steps below to remove and replace the insert.
1.
Disconnect the Safety Feed adapter cap from the empty sanitizer container.
2.
Disconnect the safety cable from the cable clip and remove the F style container from
the jug rack.
3.
Using the special Safety Feed removal tool, remove the Safety Feed dip tube from the
empty container. Center the tee handle tool over the Safety Feed dip tube and turn in
a clockwise direction while pushing down on the dip tube. As the tool bites into the
dip tube it will begin to turn. Pull up on the tee handle to remove the Safety Feed dip
tube for disposal.
The dip tube is damaged when
removed and is typically
designed to be disposed of after
removal. Reusing the dip tube
will result in improper pump
operation.