21
C) Playing
Load Sequence
A Sequence can be loaded into
memory while in SEQ MODE by
pressing one of the 8 Tone buttons '1-
8'. The Sequence that is stored under
the Tone button selected will be
loaded to memory
If you press the 'CART' button while in
SEQ MODE the data written into the
sequencer will be played.
The first
note of the sequence will only sound
once a clock has been received.
This
allows a seq to be queued to start.
When all the notes are played the data
will return to the beginning and be
played again from the start. Pressing
the 'CART' button once more will stop
the sequence playing immediately.
The tempo of the playing will be
determined by the clock source. If the
clock source is the Internal Clock then
the tempo will be set by the Master
Clock which can be further divided
using the SEQ STEP TIMING button.
Settings made in the Sequence
Control parameters will effect
Sequence playback.
432 - Oneshot (0=Loop,1=play once & stop)
433 - KeyPlayDown (0=Seq always plays when
enabled,1=Only plays when enabled &
key is down)
434 - AutoTranspose (0=actual seq notes,
1=transpose last played)
435 - AutoTransposeReset (0=Continue seq in
new transpose, 1=reset seq to step 1 on
new transpose value)
436 - AutoComplete (0=Sudden Death,1=All
keys up stops seq)
It is possible to play along with the
sequencer. The Kiwi-30 has 6 voices
in total and if not enough voices
remain for all the sequence note(s)
then notes will be lost according to
the steal rules that have been
specified in parameter 243 (Voice
Steal Mode). i.e. if the sequence step
has four notes and three are being
played then one note will not sound.
Note - If a new sequence or Tone is
loaded while a sequence is playing
the load of the Tone and Seq will
delay until the current sequence
reaches the end and is about to loop
back to the start. At this point the
Tone and Sequence (if auto load
enabled) will then load and the next
note(s) to sound will be with the new
selection. If the new Tone does not
have a sequence running when it is
saved the sequence that is running
will stop.
Note - If the Master clock source is set
to the Midi Clock the Sequence will
not play if the midi clock is not
present.
www.kiwitechnics.com