15
Figure 3-2
Typical Air Supply Filter with auto drain, Regulator,
and Lubricator (if included).
3.6.2
NOTICE
Piping - Pipe should be sized to accommodate the hoist airflow requirements.
Table 3-1
gives recommended pipe sizes.
Table 3-1
Air Supply Pipe and Hose Sizes
Model
Diameter of Supply Pipe
Diameter of Supply Hose
TCL250C/P
TCL500C/P
TCL1000C2/P2
Inside diameter
3/4” or larger
Inside diameter
1/2” or larger
3.6.3
NOTICE
Hoses - The connection from the air supply system piping to the hoist must be
made with a flexible pressure hose. Due to normal line losses in air supply lines:
◼
Do not use hose smaller than specified in Table 3-1, and
◼
Limit the length of the hose to that specified in Figure 3-3.
◼
If your application exceeds these requirements consult factory.
◼
The use of “Quick Couplers” is to be avoided. Quick Couplers restrict the air flow that will affect
hoist performance.