3.4
Air Filtration
3.4.1
!
CAUTION
The air entering the hoist inlet must not contain any particulate greater than 5
microns in size. Therefore, the hoist must have a 5 micron filter in its air supply. If using a lubricator,
the filter must be upstream.
3.4.2
The filter servicing the hoist can also service other hoists and air consuming equipment. In this case,
the air filter must be sized for the total air consumption of the equipment it is servicing.
3.4.3
It is highly recommended to use a filter with automatic draining capability, to prevent excessive
moisture accumulation.
3.5
Air Dryer
-
!
CAUTION
To prevent corrosion and hoist malfunction, employ an air dryer in the air
supply system to ensure that dry air is supplied to the hoist. If there is moisture in the air supplied to the hoist,
this moisture will cause corrosion on internal hoist components during periods when the hoist is idle leading to
hoist malfunction.
3.6
Piping, Hoses And Fittings
3.6.1
!
CAUTION
System Configuration - The system should be configured as shown in Figure 3-1.
Since moisture tends to accumulate in compressed air systems, corrosion may result if the system is
not periodically drained.
◼
Arrange for a drain in the air supply piping at the lowest point in the piping, and
◼
Periodically drain the system to remove moisture/water from the system and to prevent corrosion.
◼
Filter, regulator (if equipped), and lubricator must be arranged in the order shown in Figure 3-2.
Figure 3-1
Diagram of Air Supply Configuration (Typical)
Содержание TCL Series
Страница 43: ...43 Figure 7 4 Single Fall Chain Connections Figure 7 5 Double Fall Chain Connections ...
Страница 52: ...10 1 Motor Valve Body and Controls 52 Figure 10 1 Motor Valve Body and Controls ...
Страница 55: ...55 This Page Intentionally Left Blank ...
Страница 56: ...10 2 Brake Gears and Load Suspension Components 56 Figure 10 2 Brake Gears and Load Suspension Components ...
Страница 61: ...61 NOTES ...
Страница 62: ...62 NOTES ...
Страница 63: ...63 NOTES ...