4
INSTALLATION INSTRUCTIONS
Unpack the Ice Maker
Removing Packaging Materials
Remove tape and glue from your ice maker before using.
■
To remove any remaining tape or glue, rub the area briskly
with your thumb. Tape or glue residue can also be easily
removed by rubbing a small amount of liquid dish soap over
the adhesive with your fingers. Wipe with warm water
and dry.
■
Do not use sharp instruments, rubbing alcohol, flammable
fluids, or abrasive cleaners to remove tape or glue. These
products can damage the surface of your ice maker.
Cleaning Before Use
After you remove all of the packaging materials, clean the inside
of your ice maker before using it. See the cleaning instructions in
the “Ice Maker Care” section.
Location Requirements
■
To ensure proper ventilation for your ice maker, the front side
must be completely unobstructed. The unit may be closed-in
on the top and three sides, but the installation should allow
the ice maker to be pulled forward for servicing if necessary.
■
Installation of the ice maker requires a cold water supply inlet
of
¹⁄₄
" (6.35 mm) OD soft copper tubing with a shut-off valve
and either a gravity-drain system or condensate pump to
carry the water to an existing drain.
■
Choose a well ventilated area with temperatures above 55°F
(13°C) and below 100°F (38°C). Best results are obtained
between 70°F (21°C) and 90°F (32°C). This unit must be
installed in an area protected from the elements, such as
wind, rain, water spray or drips.
■
When installing the ice maker under a counter, follow the
recommended opening dimensions shown. Place electrical
and plumbing fixtures in the recommended location as
shown.
NOTE: Do not kink or pinch the power supply cord between
the ice maker and cabinet.
■
You should choose a location where the floor is even. It is
important for the ice maker to be level in order to work
properly. If needed, you can adjust the height of the ice maker
by changing the height of the leveling legs. See the “Leveling”
section.
Electrical Requirements
Before you move your ice maker into its final location, it is
important to make sure you have the proper electrical
connection:
A 115 Volt, 60 Hz., AC only 15-amp electrical supply, properly
grounded in accordance with the National Electrical Code and
local codes and ordinances, is required.
It is recommended that a separate circuit, serving only your ice
maker, be provided. Use a receptacle which cannot be turned off
by a switch or pull chain.
WARNING
Excessive Weight Hazard
Use two or more people to move and install ice maker.
Failure to do so can result in back or other injury.
A. Recommended location for electrical and plumbing
fixtures.
B. Floor level
14
1/2
"
(36.8 cm)
18"
(45.7 cm)
24"
(60.1 cm)
9"
(22.9 cm)
28
1/2
"
(72.4 cm)
34"
(86.4 cm)
Min.
34
1/2
"
(87.6 cm)
Max.
3
1/2
"
(8.9 cm)
A
B
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
WARNING