5-5
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
CONVECTION ELEMENT
Refer to page 4-18 for the procedure for servic-
ing the convection element.
1.
Unplug range or disconnect power.
2.
Turn off gas supply to range.
3.
Disconnect one of the wires from the con-
vection element terminals.
4.
Set the ohmmeter to the R x 1 scale.
5.
Touch the ohmmeter test leads to the
convection element terminals. The meter
should indicate between 14 and 22
Ω
CONVECTION FAN MOTOR
Refer to page 4-18 for the procedure for servic-
ing the convection fan motor.
1.
Unplug range or disconnect power.
2.
Turn off gas supply to range.
3.
Disconnect one of the wires from the con-
vection fan motor terminals.
4.
Set the ohmmeter to the R x 1 scale.
5.
Touch the ohmmeter test leads to the
convection fan motor terminals. The meter
should indicate between 29 and 41
Ω
.