REMOVING THE POWER SUPPLY CORD
1.
Unplug range or disconnect power.
2.
Turn off gas supply to range.
3.
Pull the range out of its mounting location
so that you can access the rear of the unit.
4.
Remove the rear panel from the unit (see
page 4-12 for the procedure).
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
WARNING
Power Supply Cord
5.
Disconnect the power supply cord con-
nector from the main harness connector.
6.
Remove the green ground wire screw
from the power supply cord.
7.
Release the strain relief from the power
cord and remove the cord from the unit.
Power Supply
Cord Connector
Green Ground Wire
Strain Relief