6-3
ERROR / FAILURE CODES
Before proceeding with any corrective action, perform the following steps to enter the Diagnostic
mode.
1. To recall last failure code, if not displayed, press the Cancel key to place the range in an idle
state.
2. Press the Cancel and Start keys in the following order: CANCEL, CANCEL, START.
3. Verify the error code displayed on the control by observing for longer than 1 minute. If the error
returns, use the applicable procedure listed below for the actual error code that is displayed.
FAILURE
(Leftmost
2 Clock
Digits)
ERROR
(Rightmost
2 Clock
Digits)
MESSAGE/DESCRIPTION
SUGGESTED CORRECTIVE ACTION PROCEDURE
F0
Default
E0
No failure
F1
Internal
E0
E1
E2
E3
E4
E9
INTERNAL ERROR
INTERNAL ERROR
INTERNAL ERROR
INTERNAL ERROR
INTERNAL ERROR
INTERNAL ERROR
PROCEDURE:
Before proceeding, perform steps 1 through 3 above chart to enter the
Diagnostic mode.
A. Unplug range or disconnect power.
B. Replace the display board.
C. Plug in range or reconnect power.
F1
Internal
E5
E6
E7
E8
INTERNAL ERROR
INTERNAL ERROR
INTERNAL ERROR
INTERNAL ERROR
PROCEDURE:
Before proceeding, perform steps 1 through 3 above chart to enter the
Diagnostic mode.
A. Unplug range or disconnect power.
B. Replace the power board.
C. Plug in range or reconnect power.
FAILURE
(Leftmost
2 Clock
Digits)
ERROR
(Rightmost
2 Clock
Digits)
MESSAGE/DESCRIPTION
SUGGESTED CORRECTIVE ACTION PROCEDURE
F2
Keypad
E0
E1
STUCK KEY (shorted key)
KEYPAD DISCONNECT or KEYPAD DISCONNECTED
PROCEDURE:
Before proceeding, perform steps 1 through 3 above chart to enter the
Diagnostic mode.
A. Unplug range or disconnect power.
B. Check that the keypad is firmly connected.
C. Plug in range or reconnect power and observe for longer than 1 minute.
D. If error remains then go to step E.
E. Unplug range or disconnect power.
F. Replace keypad.
G. Plug in range or reconnect power and observe for longer than 1 minute.
H. If error remains then go to step I.
I. Unplug range or disconnect power.
J. Replace display board.
K. Plug in range or reconnect power.
Содержание KGRA806P
Страница 12: ...1 8 NOTES ...
Страница 24: ...2 12 NOTES ...
Страница 26: ...3 2 NOTES ...
Страница 56: ...4 30 NOTES ...
Страница 65: ...5 9 Display Board Connector Pinouts Low Voltage Transformer ...
Страница 66: ...5 10 Power Board ...
Страница 68: ...5 12 Low Voltage Transformer Display Board Connector Pinouts ...
Страница 69: ...5 13 Power Board ...
Страница 70: ...5 14 NOTES ...
Страница 82: ...7 6 NOTES ...
Страница 84: ......