15
ENGLISH
FIRST IGNITION (COMMISSIONING) PHASES
• Make sure you have read and understood this
manual
• Remove all flammable materials from the appliance
(manuals, labels, etc.). In particular remove any
labels from the glass
• Make sure the technician has carried out first
ignition for the product, and also filled the pellet
tank for the first time (see the “loading pellet”
paragraph in the instructions for use)
LOADING THE PELLETS INTO THE TANK
To load the pellets into the tank (placed below) open
the bottom sliding drawer.
FUEL
Use UNI EN ISO 17225-2 category A1 wood pellets
or similar regulatory products with the following
characteristics.
diameter 6 mm
length 3-4 cm
humidity <10 %
For reasons of safety and respect for the environment,
DO NOT burn: plastics, painted wood, coal or waste
bark or other unsuitable material.
Do not use the cooker as an incinerator.
Caution
Using fuels other than those specified can
damage the appliance.
INSTRUCTIONS FOR USE
On first ignition, there may be a slight
smell of paint, which will disappear in a
short time.
USER/INSTALLER
Содержание KE 90 P