IOM/UP_METRIC Issue Date: 31/12/2007
Page 43 of 66
Last Revision: 12/06/2012
JOINT FLANGE
TIGHTENING TORQUES AND SEQUENCE
Stud and Nut use in this main joint flange of UP pumps should be tightened to the
torques stated in table 1 and in the sequence stated in Fig.
STUD SIZE
TIGHTENING TORQUES
M12
M16
M20
M24
250Kg-CM
650Kg-CM
1270Kg-CM
2200Kg-CM
2.
Tightening sequence.
2.1 Tighten the four corner stud marked ‘X’ 1, 2, 3, and 4
2.2 Work outward along shaft axis towards the stuffing boxes in opposite quarters
tightening nut in regions 5, 6, 7 and 8.
2.3
Work outwards along the branch and in opposite quarters tightening nuts in regions
9, 10, 11, and 12.
2.4 Repeat the whole sequence.
Sleeve Location
Содержание 8 UP 200/38
Страница 2: ......
Страница 16: ...IOM UP_METRIC Issue Date 31 12 2007 Page 16 of 66 Last Revision 12 06 2012...
Страница 20: ...IOM UP_METRIC Issue Date 31 12 2007 Page 20 of 66 Last Revision 12 06 2012...
Страница 42: ...IOM UP_METRIC Issue Date 31 12 2007 Page 42 of 66 Last Revision 12 06 2012...
Страница 46: ...IOM UP_METRIC Issue Date 31 12 2007 Page 46 of 66 Last Revision 12 06 2012 8 0 GENERAL OUTLINE DIMENSIONS...
Страница 53: ...IOM UP_METRIC Issue Date 31 12 2007 Page 53 of 66 Last Revision 12 06 2012 10 0 EXPLODED VIEW...
Страница 54: ...IOM UP_METRIC Issue Date 31 12 2007 Page 54 of 66 Last Revision 12 06 2012...
Страница 55: ...IOM UP_METRIC Issue Date 31 12 2007 Page 55 of 66 Last Revision 12 06 2012...
Страница 56: ...IOM UP_METRIC Issue Date 31 12 2007 Page 56 of 66 Last Revision 12 06 2012...
Страница 57: ...IOM UP_METRIC Issue Date 31 12 2007 Page 57 of 66 Last Revision 12 06 2012...
Страница 58: ...IOM UP_METRIC Issue Date 31 12 2007 Page 58 of 66 Last Revision 12 06 2012...
Страница 59: ...IOM UP_METRIC Issue Date 31 12 2007 Page 59 of 66 Last Revision 12 06 2012...