To ensure safe operation:

 

 

Gasoline  is  extremely  flammable  and  explosive  under  certain 

conditions. Refuel in a well ventilated area with the engine stopped. 

Keep  away  from  smoking  materials,  sparks  and  other  sources  of 

combustion  when  refueling  the  generator.  Always  refuel  in  a 

well-ventilated location. 

Wipe up spilled gasoline at once.

   

Restrict use of the generator in

 high-hazard risk

 areas. 

 

Connections for standby power to a building's electrical system must 

be made by a qualified electrician and must comply with all applicable 

laws and electrical codes. Improper connections can allow electrical 

current  from  the  generator  to  back  feed  into  the  utility  lines.  Such 

back  feed  may  electrocute  utility  company  workers  or  others  who 

contact  the  lines  during  a  power  outage,  and  when  utility  power  is 

restored,  the  generator  may  explode,  burn,  or  cause  fires  in  the 

building's  electrical  system.  This  generator  is  not  designed  to  be 

connected  to  an  automatic  transfer  switch.  Serious  damage  to  the 

engine and inverter module may result. 

 

  Always make a pre-operation inspection before you start the engine.                       

Place  the  generator  at  least  three  feet  or  one  meter  away  from 

buildings or other equipment during operation. 

Operate the generator on a level surface to prevent fuel spillage or oil 

starvation. 

Know how to stop the generator quickly and understand operation of 

all    the  controls.    Never  permit  anyone  to  operate  the  generator 

without  proper  instructions.  Keep  children  and  pets  away  from  the 

generator when it is in operation. 

Never  operate  the  generator  with  the  door  open  or  any  panels 

removed.  Do  not  operate  in  any  enclosure  such  as  an  RV 

compartment. 

Keep away from rotating parts while the generator is running. 

The  generator  is  a  potential  source  of  electrical  shocks  when 

misused; do not operate with wet hands. 

Do not operate the generator in rain or snow or let it get wet. 

Содержание SINEMASTER IG4300

Страница 1: ...SINEMASTER DIGITAL GENERATOR IG4300 OWNER S MANUAL ...

Страница 2: ...This page intentionally blank ...

Страница 3: ...nent part of the generator and should remain with it if it is resold Pay special attention to statements preceded by the following words Failure to properly follow these precautions can result in property damage serious injury or DEATH Read all labels and the owner s manual before operating this generator Generators produce carbon monoxide a poisonous colorless odorless gas that can cause death or...

Страница 4: ...d Indicates a possibility of personal injury or equipment damage if instructions are not followed NOTE Gives helpful information If a problem should arise or if you have any questions about the generator consult an authorized dealer or service center Our generators are designed to give safe and dependable service if operated according to the instructions Read and understand the Owner s Manual befo...

Страница 5: ...arnings and Cautions 13 5 2 AC Power Applications 14 5 3 Voltage Selection Switch 15 5 4 AC Power Operation 15 5 5 Output and Overload Indicators 16 5 6 Smart Throttle 17 5 7 Air Conditioner Operation 18 5 8 DC Power Operation 18 5 9 Low Oil Alarm System 20 5 10 Digital Display Panel 20 6 STOPPING THE ENGINE 22 6 1 Normal Shutdown 22 6 2 Emergency Stop 22 7 MAINTENANCE 23 7 1 Emission Control Syst...

Страница 6: ...Generator Exercise 29 9 TROUBLESHOOTING 30 10 SPECIFICATIONS 32 11 WIRING DIAGRAM 33 12 WHEEL KIT INSTALLATION 34 13 WARRANTY 36 13 1 Limited Warranty Kipor Power Products 36 13 2 Emission Control Warranty 37 13 3 California Emissions Control Warranty Statement 39 14 EMISSION CONTROL SYSTEM 40 ...

Страница 7: ...ovide adequate ventilation The muffler becomes very hot during operation and remains hot for several minutes after stopping the engine Be careful not to touch the muffler while it is hot Let the engine cool before storing the generator indoors The engine exhaust system will be heated during operation and remain hot immediately after stopping the engine To prevent burns pay attention to the warning...

Страница 8: ...urn or cause fires in the building s electrical system This generator is not designed to be connected to an automatic transfer switch Serious damage to the engine and inverter module may result Always make a pre operation inspection before you start the engine Place the generator at least three feet or one meter away from buildings or other equipment during operation Operate the generator on a lev...

Страница 9: ... 器 加油 盖 排气 口 高温 标记 空气 指数 信息 铭牌 Fuel Level Indicator Fuel Filler Cap Air Quality Index Air Exhaust Muffler Warning Starter Grip 火花 塞 机油 尺 维修 门 电瓶 空滤 进气 口 控制 面板 碳罐 Carbon Canister Control Panel Inlet Air Filter Battery Service Door Oil Dipstick Spark Plug ...

Страница 10: ...器 油开 关 空滤 盖 IG4300 Fuel Switch 240V AC Receptacle Circuit Protector LED Monitor Ground Terminal Smart Throttle Electric Starter Choke Low Oil Alarm RED Voltage Selection Switch DC Receptacle Overload Alarm RED Output Indicator GREEN 30A 120V Receptacle GFCI Receptacle Air Filter Cover Air Filter Cover Filter ...

Страница 11: ...w it clearly Refer to this number when ordering parts or making technical inquiries Engine serial number Please record this information below and keep this manual in a safe place along with the bill of sale Serial Number __________________________________ Date of Purchase ________________________________ Place of Purchase ________________________________ Engine serial number ...

Страница 12: ... U S automobile manufacturer s requirements for API Service Classification SG SF Select the appropriate viscosity for the average temperature in your area SAE Viscosity Grades Open the left maintenance cover Remove and wipe the oil dipstick with a clean rag Check the oil level by inserting the dipstick in the filler hole tighten the dipstick and screw it out If the oil level is below the end of th...

Страница 13: ...er in the fuel tank After refueling tighten the fuel filler cap securely Gasoline is extremely flammable and is explosive under certain conditions Refuel in a well ventilated area with the engine stopped Keep all smoking materials sparks and any other source of combustion away from the generator during refueling Do not overfill the fuel tank there should be no fuel in the filler neck After refueli...

Страница 14: ...r element to be sure it is clean and in good condition Open the left side maintenance cover Remove the air cleaner cover remove the paper element from the air cleaner cover and check the element Replace the element if dirty or the filter paper is torn Never run the engine without the air cleaner Rapid engine wear will result from contaminants such as dust and dirt being drawn through the carbureto...

Страница 15: ...the first time or after long term storage or after running out of fuel turn the fuel valve lever to the ON position then wait for 10 to 20 seconds before starting the engine 4 1 Starting Procedure 4 1 a Turn the fuel valve lever to the ON position 油开 关 空滤 盖 IG4300 Fuel Switch ...

Страница 16: ... knob out to the CLOSED position Do not use the choke if the engine is already warm or the ambient air temperature is high 4 1 c Insert the engine key and turn the engine switch to ON position Engine switch 阻风 门开 关 Choke knob ...

Страница 17: ...il resistance is felt then pull the starter grip briskly toward the arrow as shown below Do not allow the starter grip to snap back Return it slowly by hand Do not let the starter rope rub against the generator body or the rope will wear out prematurely 4 1 e Push the choke knob in to the OPEN position as the engine warms up Fig 9 a Fig 9 b Engine switch Starter grip 阻风 门开 关 Choke Knob ...

Страница 18: ... each 1000 feet or 305 meter increase in altitude The effect of altitude on the horsepower will be greater than this if no carburetor modification is made Operation of the generator at an altitude lower than the carburetor is jetted for may result in reduced performance overheating and serious engine damage caused by an excessively lean air fuel mixture Be sure to have any modification reversed at...

Страница 19: ...ontact the lines during a power outage when utility power is restored the generator may explode burn or cause fires in the building s electrical system Do not connect this generator to an automatic transfer switch Serious damage to the engine and inverter module may result Limit operation requiring maximum power to 30 minutes For continuous operation do not exceed the rated power of 2800 watts or ...

Страница 20: ... when using AC supply 5 2 AC Power Application The generator has the capability to provide 120V and 240V AC Power It can do so simultaneously depending on the needs of the user However it is important to understand the receptacles their current limitations and how to distribute power efficiently 120V 20A GFCI Receptacle 20 240V 30A Receptacle Voltage Selection Switch 20V 30A Receptacle The GFCI gr...

Страница 21: ...ch is in the 120 240V position the generator supplies both 120V and 240V AC power If you operate the generator with the switch in this position the electric current is limited to 15 amps to the 120V receptacles although it can provide 15 amps at 240V from the 120 240V receptacle 2 When the voltage selection switch in the 120V position the generator supplies 120V AC only It can supply a full 30 amp...

Страница 22: ...the connected appliance the output indicator will go out and the overload indicator will go on and current to the connected appliance will be shut off Stop the engine if the overload indicator light comes ON and investigate the overload source The engine will continue to run even though it is not producing any AC power The engine must be stopped and then the generator restarted to resume normal op...

Страница 23: ...e automatically when the electrical load is disconnected and returns to the proper speed required by the electrical load when the load is reconnected The engine speed varies according to the amount of load applied to the generator Placing the smart throttle in the on position is recommended to minimize fuel consumption and engine noise while in operation When high electrical load appliances are co...

Страница 24: ...utomotive type batteries only It is not designed to operate DC motors Output voltage is 15 30V DC output will vary according to the position of the Smart throttle switch a Connect the charging cable to the DC receptacle of the generator and then to the battery terminals To prevent the possibility of creating sparks near the battery connect the charging cable first to the generator then to the batt...

Страница 25: ...C output is to be used to charge batteries only Serious damage to the stator windings can occur if connected to a DC motor or transformer b Start the generator The DC receptacle may be used while the AC power is in use The DC receptacle is protected from an overload with a fuse If the DC circuit is overloaded the 5 amp fuse will blow and power to the DC receptacle will cease The red light on the D...

Страница 26: ... will not run If this occurs search for any oil leaks Add engine oil to resume normal operation 5 9 Digital Display Panel The generator features a digital panel that displays operating parameters and service reminders Pressing the button will cycle the display through voltage current frequency battery voltage and accumulated hours Push the button to read the desired parameter Operating Parameters ...

Страница 27: ...rvice air cleaner SV4 N A diesel models SV5 Adjust valve clearance SV6 Check fuel tank and fuel lines To see the prescribed service intervals see chapter 7 Maintenance When a service reminder is displayed you can press the selection button to restore the operating parameter however the service code will be displayed again in two seconds After the specified maintenance item is addressed the code ca...

Страница 28: ...uipment and disconnect from the generator 2 Turn off the engine switch 3 Turn the fuel valve lever to the OFF position 6 2 Emergency Stop Turn the start switch to the OFF position Continually stopping the generator with a load applied can lead to damage of the control module ...

Страница 29: ...ne utilizes a precise air fuel ratio and emission control system to reduce the emissions of carbon monoxide NOX hydrocarbons and evaporative fuel emissions Regulation Your engine has been designed to meet current Environmental Protection Agency EPA and the California Air Resources Board CARB clean air standards The regulations dictate that the manufacturer provide operation and maintenance standar...

Страница 30: ... performance The manufacturers of replacement parts and accessories have the responsibility to guarantee that their replacement products will not adversely affect emission performance Maintenance Maintain the generator according to the maintenance schedule in this section Service items more frequently when used in dusty areas or under conditions of high load temperature and humidity Air Quality In...

Страница 31: ...Fuel tank and strainer Clean 3 Fuel lines Check Every 2 years Replace as necessary 3 NOTE 1 Log hours of operation to determine proper maintenance 2 Service more frequently when used in dusty conditions 3 These items should be serviced by an authorized KIPOR service center unless the owner has the proper tools and is mechanically proficient Refer to the KIPOR Generator and Engine shop manuals To l...

Страница 32: ...ghten the bolt securely 4 Refill with the recommended oil and check the level 5 Close the left side maintenance cover 7 4 Air cleaner service A dirty air cleaner will restrict airflow to the carburetor and allow dirt into the engine Service the air cleaner regularly Service more frequently when operating the generator in extremely dusty areas Do not use gasoline or low flashpoint solvents for clea...

Страница 33: ...latch the service door 7 5 Spark plug service Recommended spark plug WR7DC To ensure proper engine operation the spark plug must be properly gapped and free of deposits 1 Open the service door 2 Remove the spark plug cap 3 Use the wrench to remove the spark plug 4 Clean any dirt from around the spark plug base Spark plug wrench 空滤 底座 滤芯 空滤 盖 用压 缩空 气从 滤芯 内侧 吹 滤芯 Air Filter Base Filter Element Air F...

Страница 34: ... hand to avoid cross threading 8 After a new spark plug has been seated by hand it should be tightened 1 2 turn with a wrench to compress the sealing washer If a used plug is being reinstalled it should only require 1 8 to 1 4 turn after being seated 9 Reinstall the spark plug cap 10 Close and latch the service door The spark plug must be securely tightened An improperly tightened plug can become ...

Страница 35: ...cessary 7 TRANSPORTING STORAGE 8 1 Transporting When transporting the generator turn the fuel valve lever OFF and keep the generator level to prevent fluid spillage Fuel vapors or spilled fuel may ignite Transporting the generator with gasoline in the fuel tank is prohibited 8 2 Extended Storage 1 Be sure the storage area is free of excessive humidity and dust 2 Drain the fuel a Open the left side...

Страница 36: ...form of gum and varnish This can lead to hard starting and rough running and possibly cause the engine not to start at all As EPA regulations dictate no kits available to renew a carburetor carburetor replacement will be necessary Fuel preservatives are readily available at leading RV and marine dealers Regularly add a fuel preservative to the generator fuel tank or fuel supply Drain the carbureto...

Страница 37: ... there enough oil in the engine Is the fuel valve on Is the engine switch on Is there fuel in the tank Turn the fuel valve on Turn the engine switch on Refill the fuel tank YES YES YES NO NO NO NO NO Still no spark To check 1 Remove the spark plug cap and clean any dirt from around the spark plug 2 Remove the spark plug and install the spark plug in the plug cap 3 Set the plug side electrode on th...

Страница 38: ...rvice center Check the electrical appliance or equipment for any defects Take the generator to an authorized KIPOR service center Replace the electrical appliance or equipment Take the electrical appliance or equipment to an electrical shop for repair Is the fuse blown Replace the fuse Take the generator to an authorized KIPOR service center YES YES NO YES NO NO YES ...

Страница 39: ...Power 5 5 HP 3600 RPM Cooling System Forced Air Ignition System Transistorized Oil Capacity 1 2 qt 1 1L Fuel Tank Capacity 3 1 gal 11 6 L Rated Load Run Time 5 hours Noise level no load full load 23 7m 62 67 dB Spark Plug WR7DC Length 30 9 in 785 mm Width 18 5 in 470 mm Height 22 4 in 569 mm Weight 162 lbs 72 5 kg Tune Up Specifications Spark Plug Gap 0 024 0 028 in 0 6 0 7 mm Valve Clearance cold...

Страница 40: ...34 11 WIRING DIAGRAM ...

Страница 41: ...35 12 WHEEL KIT 1 Axle shaft 2 2 5 swivel locking wheel 3 Bolt M8X16 4 Wheel 5 Bolt M6X16 4 1 2 3 5 ...

Страница 42: ...Install an iiner washer the wheel and an outer washer d Secure with a cotter pin 1 Wheel 2 Axle 3 Cotter Pin 4 Washer B Install the locking swivel wheel a Align the hole in the wheel plate with the predrilled holes in the chassis b Secure with 4 M6X16 bolts 1 2 5 locking swivel wheel 2 M6X16 bolt 1 2 3 4 1 2 ...

Страница 43: ...unfeasible the Kipor distributor will pay for shipping of the unit from the repair center to the designated distributor facility and the shipping of a replacement unit Kipor or its distributor reserves the right to repair or replace these parts at its option The return of defective parts may be requested Anything replaced under warranty becomes the property of Kipor TO OBTAIN WARRANTY SERVICE Cont...

Страница 44: ... If any covered part on your engine is defective the part will be repaired or replaced by Kipor Power Equipment Owner s Responsibilities You are responsible to maintain the engine as defined in your Kipor Generator Owner s Manual Kipor recommends that you retain all record receipts covering maintenance on your engine but Kipor Power Equipment cannot deny warranty claims based on the lack of receip...

Страница 45: ...l be free of defects in materials and workmanship for a period of two years from the date of the original retail customer 4 Repair or Replacement Cost Repair or replacement of any emissions control system part will be repaired at no charge to the owner including diagnostic labor which would determine an emissions control system defect exists if the repair is performed at an authorized Kipor repair...

Страница 46: ...ranted for two years If any emissions related part on your engine is defective the part will be repaired or replaced by Kipor Power Equipment Owner s Warranty Responsibilities 1 As the SORE owner you are responsible for the performance of the required maintenance listing in your owner s manual Kipor recommends that you retain all receipts covering maintenance on your SORE but Kipor cannot deny war...

Страница 47: ...nd be released to the atmosphere 2 A carbon activated canister collects gasoline vapors from the fuel tank and returns them to the combustion chamber for burning 3 A catalyst is built into the muffler to further treat the engine exhaust 4 A secondary air injection valve adds combustion air to ignite unburned fuel in the exhaust Contact your authorized Kipor service center to obtain the correct rep...

Страница 48: ...42 Fuel System ...

Страница 49: ...de Carbon Canister Location 二次 补气 阀组 件 二次 补气 阀垫 片 螺栓 消声 器本 体总 成 垫片 A 消声 器弯 管 防火 帽组 件 碳罐 Generator Frame Canister Spark Arrestor Secondary Air Valve Gasket Bolt Muffler with Catalyst Gasket Connection to exhaust manifold ...

Страница 50: ...44 Exhaust System ...

Отзывы: