26
Oil drain bolt
Oil dipstick
1. Open the left side maintenance cover.
2. Remove the oil dipstick.
3. Remove the drain bolt and drain the oil. There is a rubber plug in the bottom of the generator pan
that can be removed to facilitate draining the oil. The generator will have to be raised off the ground
and supported while the oil drains. Retighten the bolt securely.
4. Refill with the recommended oil and check the level.
5. Close the left side maintenance cover.
7.4 Air cleaner service
A dirty air cleaner will restrict airflow to the carburetor and allow dirt into the engine. Service the air
cleaner regularly. Service more frequently when operating the generator in extremely dusty areas.
■
Do not use gasoline or low flashpoint solvents for cleaning. They
are flammable and explosive under certain conditions.
■
Never run the generator without the air cleaner. Rapid engine wear
may result.