27
6.10 Ignition Control Relay
Start the engine, turn off the smart throttle and measure the voltage between green and yellow/green
wires on the connection of the control module. Replace the ignition control module if the voltage exceeds
stipulated voltage.
Ignition voltage
(AC)
27~32V
Yellow Green Black
Orange Grey
Green Yellow Green
6.11 Inverter Module
Unplug the two stator input connections to the module. Start the engine and take a voltage reading at
both 4P connections. Readings between pins 1-2, 2-3, 1-3 should be 255VAC ± 15V.
2 3
1
Alternator Input Terminals 4P connectors
Содержание IG6000
Страница 1: ...IG6000 IG6000h Generator Service Manual The Coast Distribution System June 1 2007 ...
Страница 8: ...4 1 4 Wiring Diagram ...
Страница 32: ...28 7 FRAME HOUSING AND FUEL TANK 7 1 Disassembly and reassembly ...
Страница 34: ...30 8 ALTERNATOR IGNITION COIL TRIGGER STARTER MOTOR FAN COVER 8 1 Component Identification ...