FP 25 E
Issue: 06/2011
50
4 .5
Lamphouse Operating Elements
1
2
5
3
4
Operating hour counter
Main switch
Fuse (6.3 A)
Press button: IGNITE
Ammeter
4 .5 .1 Main Switch
Toggle switch in position “I”:
The xenon lamp is ON. The ventilation runs after when the xenon lamp turns off.
Toggle switch in position “0”:
The xenon lamp is OFF.
Manually switch on or switch off
• Switch on the main switch (position “I”). The fan is running.
• Switch off the main switch (position “0”). The fan is off.
X
NOTE
The fan runs after (approx. 5 minutes) when the projector and the xenon lamp are
switched off. This thermal switch is operating with a temperature of 60° C.
If the temperature is less than 45° C the switch resets.
4 .5 .2 Operating Hour Counter
The operating hour counter shows the hours the xenon bulb has been in operation.