background image

3

Installation instructions

3.1 First connect the winch and the rolling pipe with bolts; then fix 
      the plastics on the pipe with film hoops, please make sure the
     pipe are on the same level with the winch. After this work, you
     could close or open the plastics.       
3.2 The winch can fit 2 models of rolling pipes; the outside diameter
      is 34mm and 27mm. When you choose 27mm pipe, you need 
      the suit, when you choose 34mm pipe, there is no need to use 
      the suit.
3.3 When the product is used on the top of the greenhouse, the 

Model 

 

Power 

Torque 

Current 

 

Voltage 

 

AC220V±20V 

Speed 

2.5 r/min 

Rolling tube 

Roofing/Side

 

3/4

″(

OD:

Φ

27

or 1

″(

OD:

Φ

33.5

 

Rolling range 

Recommendation

 

3/4

Rolling tube 

100m(L)×4m(H) 

Guide tube 

Roofing

 

3/4

″(

OD:

Φ

27

 

Maximum range 

(output shaft) 

45 Rounds 

Protection degree 

IP55 

 

120W

0.9 A

60N · m

120N · m

120N · m

WARNING: 
       1. All power distribution devices must be selected and installed
           by professionals;
       2

In order to use the electricity safely, the terminal box of the 

           winch should be connected with the grounding cable reliably.
       3. After the cables are connected, the water clog in the 
           terminal box and the lid of the water proof box should be
           sealed tightly to prevent rain from entering.
       4. It is no problem for 5 pieces of motors in paralleling circuits,
           if the paralleling motors is more than 5 pieces,you must use 
           the Electric Control Board,which can only control the motors
           less than 5 pieces.

Counter-clockwise 

button

QF

Breaker

L

N

Clockwise button

Stop button

L

NC

L

L

NO

NO

AC Contactor

Grounding wire

Live wire L

Neutral wire N

AC220V

Contactor

Contactor

220V Electric film reeler Wiring Diagram 2

220V 

Electric 

film reeler

Distribution cabinet

Blue

Red

N

Black

PE

Yellow-green

on L 

off

Caution: Contactor model: CJX20901. 

If you need change other brand or 

model, please refer to professional 

personnel for confirming the wiring.

GMA120-S-A1

3.1 r/min

Содержание GMA120-S-A1

Страница 1: ...120 S A1 45 EN01 Manufacturer Beijing Fenglong Greenhouse Technology Co Ltd Address Chinese Academy of Agricultural Sciences No 12South Street Zhongguancun Haidian Beijing 100081 China ZIP 100081 Tel 86 10 62149667 Fax 86 10 82108614 Web www bflc com cn ...

Страница 2: ... authorized unit or user to disassemble and maintain 4 Damage caused by force majeure factors 5 Other purpose except ventilation and shading 12 Dear Customers We are grateful for your continuous trust and support over the decades We will do our best to continue the all round service and quality products Beijing Fenglong is a high tech company with high R D investment supplying equipments ranging f...

Страница 3: ...e service CONTENTS 1 Cautions and dangerous 1 2 Product features and performance data 2 3 Installation instructions 6 4 Limit range adjusting 9 5 Maintenance 10 6 Common problems and solutions 10 7 Packing list 11 8 Certificate of product quality 12 The products are subject to design and performance updates so it might be a little different from this manual book But it will not affect your usage T...

Страница 4: ...angerous 1 1 Proper using and maintenance will help to extend the life of film reeler please operate in accordance with this instruction Manual 1 2 Input Voltage of this product is AC220V Please connect the wire under guidance of the professional 1 3 Do not use voltage over AC220V the maximum voltage fluctuations should not exceed 10 The installation must be equipped with reliable grounding cable ...

Страница 5: ...nd there would be dange of power shock 2 1 11 Please check the bolt and nuts regularly in case of looseness from the motor 1 12 The electric motor must keep in a direct line with the roll up tubing and the bending degree should not too large or this will cause the damage of overloading 1 13 Please note the mounting position of power cord to prevent it winding or broken 1 14 Please do not switch it...

Страница 6: ...switch the proper position and then fasten the lock bolts 3 4 5 If there is power failure during the operation of the products and you would like to lower down the rolling pipe urgently you could hold the pipe first and loosen the connection between the pipe and the motor then lower the pipe slowly 3 5 Installation dimension Manual operation area Manual operation illustration When there is power f...

Страница 7: ... stop When the AC220V power is connected with open L and N the winch rotates in a positive direction When the AC220V power is connected with closed L and N the winch rotates in a reverse direction 220V Electric film reeler Wiring Diagram 1 QF Breaker L N 1 2 3 Blue L Red N Black PE Yellow green Distribution cabinet Grounding wire Live wire L Neutral wire N AC220V Reversing switch Reversing switch ...

Страница 8: ...distribution devices must be selected and installed by professionals 2 In order to use the electricity safely the terminal box of the winch should be connected with the grounding cable reliably 3 After the cables are connected the water clog in the terminal box and the lid of the water proof box should be sealed tightly to prevent rain from entering 4 It is no problem for 5 pieces of motors in par...