MQVL60 / MQVLBG60
Clearance to Combustibles
Front (Furniture, etc. from glass)
36” [92cm]
Side (from Stand-off) MQVL60
0” [0cm]
Side (from glass doors) MQVLBG60
18” [46cm]
Back (from Stand-offs)
0” [0cm]
Floor
0” [0cm]
Raised Hearth at Glass Opening
0” [0cm]
Minimum Ceiling Height (from bottom of fireplace) 76” [193cm]
Top (from Stand-offs)
0” [0cm]
Top of 90° Bend under 76” Enclosure
4” [10.2cm]
Top of 90° Bend over 76” Enclosure
4” [10.2cm]
VENTING SYSTEMS
Top of Horizontal Pipe
1/1/2” [3.8cm]
Side & Bottom of Horizontal Pipe
1” [2.5cm] All Vent Systems
Vertical Vent Pipe in Enclosure under 76”
4-9/16” [11.6cm] All Vent Systems
Vertical Vent Pipe in Enclosure over 76”
1” [2.5cm] All Vent Systems
SIDE VIEW (MQVLBG60 SHOWN)
No Framing on
Top
Sides
of fireplace
for MQVL60 Single
Side Units
Top opening of Chase
must be flush or within
3/4”
of Enclosure Top
(
Min 200 sq. in
.
with
no grill, 220 sq. in.
with grill)
*
THIS AREA
MUST BE OPEN
MIN 550 Sq. In.
Bottom Air Opening
Options – Min 102 sq. in.
CEILING
76”
MIN
CEILING
Opening must not be
blocked by floor covering
Top of Enclosure
must be sealed so
that no heat can
escape.
⚠
NOTE
If using insulation in
vented chase (i.e. for
outside wall), wall board /
drywall is required to
support all insulation.
Vented chase must be
clean and free of all
debris (i.e. loose
insulation, pieces of
wood, etc.).
14-1/2”