background image

Valve System Parts

 

(If Serial Number is LESS than: 31089 for MDV30; 38322 for MVDV38)

 

1000-P136WR  Thermopile GOAI-524

 

1001-P035SI  Electrode Sparker 915.035 SIT

 

1001-P129SI  Thermocouple 290.129 SIT unified

 

1001-P157SI  Orifice Pilot LP 977.157 SIT

 

1001-P159SI  Orifice Pilot NG 977.159 SIT

 

1001-P508SI  HT Cable 16

 

1001-P633SI  Valve Nova LP Hi/Lo 0820633/651

 

1001-P634SI  Valve Nova NG Hi/Lo 0820634/652

 

1001-P605SI  Pilot Burner LP 190.605 unified SIT

 

1001-P606SI  Pilot Burner NG 190.606 unified SIT

 

Valve System Parts 

New Top convertible SIT System (Millivolt) - 

MDV31/39 (If Serial Number is GREATER than: 31088 for MDV30 
or 38321 for MVDV38) 

1000-P136WR  Thermopile GOAI-524  

 

1001-P069SI     Electrode & Cable 915.069 TC SIT  

 

1001-P216SI     Thermocouple 290.216 TC SIT  

 

1001-P165SI  Orifice Pilot NG 977.165 TC SIT

 

1001-P167SI  Orifice Pilot LP 977.167 TC SIT

 

1001-P633SI  Valve Nova LP Hi/Lo 0820633/651

 

1001-P634SI  Valve Nova NG Hi/Lo 0820634/652

 

1001-P713SI     Pilot Burner LP 199.713 TC SIT  

 

1001-P714SI  Pilot Burner NG 199.714 TC SIT

 

Valve System Parts  - 

IPI  System

 

Electronic Ignition/Remote Control IPI

 

EGTRC  

Remote Control IPI (Thermostat)  

 

EGTMRCN  

Remote Control IPI (Thermostat/Modulating - NG)    

EGTMRCP  

Remote Control IPI (Thermostat/Modulating - LP)  

 

EGTFRCN 

Remote Control IPI (Thermostat/Modulating/Fan - NG) 

EGTFRCP 

Remote Control IPI (Thermostat/Modulating/Fan - LP) 

Electronic Ignition Replacement Parts IPI  

 

1002-P001si   Valve IPI (NG; ON/OFF)  

 

1002-P002si  Valve IPI (LP; ON/OFF)

 

1006-P002si  Valve IPI (NG; Hi/Lo)

 

1006-P603si  Valve IPI (LP; Hi/Lo)

 

1002-P047si  Pilot Assembly (LP)

 

1002-P033si  Pilot Assembly (NG)

 

1002-P089si   Spark Electrode (Long)  

 

1002-P113si   Electrode Flame Sensor (Long)  

 

1002-P302si   IPI Ignition Board  

 

1002-P850si   AC Wall Adapter  

 

1002-P12BH     Battery Pack  

 

1002-P912si  Wiring Harness

 

1002-P166si  Orifice Pilot (NG #62)

 

1002-P168si  Orifice Pilot (LP #35)

 

1002-P013si  Stepper Motor (NG)

 

1002-P012si  Stepper Motor (LP)

 

1002-P016is  Hi/Lo Regulator (NG)

 

1002-P014si   Hi/Lo Regulator (LP)  

 

Miscellaneous Parts

 

1000-150GE  #Silicone GE Red IS806 #736

 

1000-150MP  #Hi-Temp Mill Pac Sealant 840099

 

1000-214 

#Piezo-Igniter 1244-17 Mark 21

 

1000-215 

#Pal Nut (18MMXI.5MM)BLK (1364.03)

 

1000-218 

#Switch Ivory (1451/001)

 

1000-227 

#Cover Ivory (86001/001)

 

1000-255 

#Orifice Brass - (State Size)

 

1000-EMBER #Glowing Moon Rock

 

3800-134 

#Explosion Felt Gasket

 

2000-080 

#Thermodisc 2450 (For Blower)

 

2000-081 

#Blower Motor QLN65/2400

 

1000-085 

#Control Variable Speed KBWC-13BV

 

1000-306 

Thermalcord - Adhesive Back for Door Frame

 

1000-305 

Ceramic Glass - Side (All Models)

 

3800-312 

Ceramic Glass - End (All Models)

 

3800-313 

Tempered Glass - End (MDV30/31 only)

 

3600-311 

Tempered Glass - Side (MDV30/31 only)

 

Conversion Kit (SIT Valve only)

 

31MDV-CKLP  LP Conversion Kit for MDVR31, MDVL31 (Millivolt)

 

31MDV-CKNG  NG Conversion Kit for MDVR31, MDVL31 (Millivolt)

 

3632RB-CKLP  LP Conversion Kit for MQRB3632 (Millivolt)

 

3632RB-CKNG NG Conversion Kit for MQRB3632(Millivolt)

 

31MDV-CKLPI  LP Conversion Kit for MDVR31LPE, MDVL31LPE (IPI)

 

31MDV-CKNGI  NG Conversion Kit for MDVR31NE, MDVL31NE (IPI)

 

3632RB-CKLPI LP Conversion Kit for MQRB3632LPE (IPI)

 

3632RB-CKNGI   NG Conversion Kit for MQRB3632NE (IPI)

 

 

Kingsman Fireplace Venting

 

Catalog

 

Number Description

 

ZDVHSK 

Horizontal Vent Starter Kit - 3 FT Length

 

Horizontal Vent Termination, Wall Thimble,

 

36” Flex Pipe, Mill Pac

 

ZDVHSKSQ   Horizontal Starter Kit

 

Square Termination, Wall Thimble,

 

3 FT Flex Pipe, Mill Pac

 

ZDVHSK5  Horizontal Vent Starter Kit - 5 FT Length

 

Horizontal Vent Termination, Wall Thimble,

 

60” Flex Pipe, Mill Pac

 

FDVVT40  Vertical Vent Termination (ONLY) 
FDVHT 

Horizontal Vent Termination

 

FDVHSQ  

Horizontal Square Termination  

 

ZDVST 

Horizontal Snorkel Termination

 

(34” Tall, 24” Center  to Center)

 

FDVHSC 

Safety Cage for Horizontal Termination

 

ZDVAIS 

Attic Insulation Shield

 

ZDVVOS 

Offset Support 

ZDVFS 

Firestop Spacer 

ZDVRS 

Roof Support

 

ZDVWT 

Wall Thimble (Horizontal Venting) 

ZDVSS 

Siding Shield

 

ZDV48GP  Galvanized Pipe 7” Dia. x 48” (Vertical Installations) 
ZDVAAF 

Flashing 7” c/w Storm Collar (1/12 to 7/12)

 

ZDVAF2 

Flashing 7” c/w Storm Collar (8/12 to 12/12) 

ZDVAF3 

Flashing 7” c/w Storm Collar Flat

 

ZDV7SC 

Storm Collar 7”

 

ZDVFK5 

Flex Kit (4” & 7” Dia.) x 2.5’ (Unexpanded) 5’ Expanded 

ZDVFK8 

Flex Kit (4” & 7” Dia.) x 4’ (Unexpanded)  8’ Expanded 

ZDVFK20  Flex Kit (4” & 7” Dia.) x 10’ (Unexpanded) 20’ Expanded

 

*Kits are complete with spring stand-offs, silicone.

 

ZDV4FC 

Flex Connector 4” Diameter 

ZDV7FC 

Flex Connector 7” Diameter 

ZDV4SS 

Spring 4” Standoff Spacer 

ZDVDFA 

Dura-Vent Fireplace Adapter

 

 

 

*In the U.S.A. 

Thermostats are not 

permitted for Vented 

Gas Fireplaces 

(ANSI Z21.50b-2009 

-Decorative)

58

Содержание MDV31

Страница 1: ...reach your gas supplier call the fire department For Propane Horizontal installations the venting must be a minimum of one foot vertical off the flue before going horizontal Installation Instructions...

Страница 2: ...he installations e g marble tile and the adhesives used to adhere this product to the walls can react with heat and cause odours It is recommended that you burn your gas fireplace or stove for a minim...

Страница 3: ...r and Grill Installation 23 LOGC31 Placement Guidelines for Model MDV31 39 24 25 MQRSP7 Rock Support Platform and MQROCK1 for Models MDV31 39 26 27 Accessories Available for Skyline ZDVRB3622 Ribbon B...

Страница 4: ...the appliance 15 Installation and repair should be done by a qualified service person The appliance should be inspected before use and at least annually by a professional service person More frequent...

Страница 5: ...A 720 2005 Edition B A carbon monoxide detector shall be located in the room that houses the appliance or equipment and shall Be powered by the same electrical circuit as the appliance or equipment su...

Страница 6: ...32 625 TOP VIEW PENINSULA RIGHT CORNER TOP VIEW SEE THRU TOP VIEW 20 0 6 0 MIN MIN 6 0 ALL UNITS CAN BE VENTED VERTICAL MAX Horizontal Run With Required Vertical Run LEFT CORNERTOP VIEW LEFT CORNER T...

Страница 7: ...f are equipped with nailing tabs Level Fireplace and nail or screw into place NOTE For Low Profile Enclosure Refer to Low Profile Enclosure Section R H FIREPLACE SHOWN FRAMING DETAIL THROUGH Combustib...

Страница 8: ...wing Ember installation refer to Log Placement Section FACING MATERIAL INSTALLATION Facing material Example DRYWALL may be installed flush with top of Fireplace Side facing to be installed to standoff...

Страница 9: ...oad Bearing MIN 36 0 FIGURE 1 FIGURE 2 SEE THROUGH FIREPLACE SHOWN FIREPLACE ASSEMBLY 1 Mount Door Cover Figure 2 First apply a small bead of High Heat Silicone to door seal Mount Door and screw into...

Страница 10: ...MATERIAL INSTALLATION Facing material Example DRYWALL may be installed Flush with top of Fireplace Side facing to be installed to standoffs only NOTE This UNIT is not Load Bearing Gyprock Gyprock DRYW...

Страница 11: ...hrough With CVCK Enclosures For Propane Horizontal Installations the venting must be a minimum of one foot vertical off the flue before the elbow on any horizontal runs of one foot or greater This all...

Страница 12: ...s depends on valve and fireplace location on riser or upper floor Fireplace Assembly 1 Mount Door Cover First apply a bead of High Heat Silicone to door seal Mount Door Cover and screw into place maki...

Страница 13: ...Framing and Facing Requirements See Through with CVCK Clean View Circulating Kit Note When CVCK is used a CVCK Kit must be installed on Both sides of the unit MDV31 with MQ36SWF Surround 13...

Страница 14: ...supplied 6 screws fasten the CVCK to the inside posts of the appliance 5 Using ten 10 DT screws install the Top Heat Shield to the upper inside portion of the CVCK A side cut view is provided to illus...

Страница 15: ...upper portion of the Surround so that the Surround Ledge is resting on top of the CVCK Deflector Lip 3 Align the Mounting Screw Holes and fasten the Surround in place with the supplied screws 4 Attac...

Страница 16: ...to wall sleeve Refer to Low Profile Enclosure Section for additional information FRAMING DETAIL HORIZONTAL RUN WITH MIN VERTICAL RUN MIN 36 0 FIGURE 1 THROUGH COMBUSTIBLE WALL 11 0 11 0 42 0 MIN For C...

Страница 17: ...FACING MATERIAL INSTALLATION Facing material Example DRYWALL may be installed Flush with top of Fireplace Side facing to be installed to standoffs only DRYWALL 17...

Страница 18: ...ER MINIMUM HEIGHT OF 52 0 MUST BE MAINTAINED FOR PROPER CLEARANCES INSULATION SLEEVE IS NOT REQUIRED THIS WILL LEAVE A 4 0 MINIMUM CLEARANCE TO COMBUSTIBLE TOP For Propane Horizontal Installations the...

Страница 19: ...m Louvered Units Only Top of 90 Bend No Sleeve in Enclosure over 52 4 inches 102mm Bottom of Top Enclosure with Insulation Sleeve 42 inches 1067mm In Low Profile Enclosures from 42 to 52 Top of Horizo...

Страница 20: ...ver the front face of the fireplace No portion of grill area or door areas can be covered except where designer Clean View Kit is used Combustible material can extend flush to the unit up to the top b...

Страница 21: ...ottom pan Refer to diagram for proper location Power cable to be routed through 6 x8 access hole 4 Connect power sensor and variable speed wall switch as shown in wiring diagram SUGGESTED LOCATION FOR...

Страница 22: ...pronged grounding plug for your protection against shock hazard and should be plugged directly into a properly grounded three prong receptacle Label all wires prior to disconnection when servicing con...

Страница 23: ...in both ends To install slide the head into one of the teardrop slots then slide Grill to opposite side repeat procedure These screws may have to be adjusted for proper alignment and length 3 All Gri...

Страница 24: ...rate bar Step 3 Locate mounting hole bottom of Log 3 onto Tab 3a and have char area touch Tab 3b TAB 3a TAB 3b TAB 4a TAB 4b TAB 2a GRATE BAR EMBER PLATES EMBERS ROCK FLAT AREA NOTCH NOTCH GRATE BAR T...

Страница 25: ...o grate bar and rest log onto flat area of Log 2 Step 6 Position Log 6 up against Logs 4 and 5 and place flat area of log on floor of fire box Step 7 Locate notched areas of Logs 2 and 3 and place Log...

Страница 26: ...ner tube Step 2 Place rocks 6 into position as shown Step 3 Place rocks 4 into position as shown Using the 2 4 s highlighted place them over the single porting crossover area as shown MQRSP7 Rock Supp...

Страница 27: ...is high lighted over the single porting crossover area as shown Step 7 Place rock 1 into position as shown Finished setup and burn If too much flame impingement on the rocks causes sooting you may ha...

Страница 28: ...en placing glass embers near the pilot area so as not block or have the glass fall over the crossover holes from the pilot to the burner as delayed ignition can occur The following types of glass are...

Страница 29: ...Embers may be used with or without other accessories ULK2 UNIVERSAL LIGHT KIT Optional Accent Lighting Kit See separate installation page NOTE Pilot Area Must Not Be Covered as delayed ignition can o...

Страница 30: ...t lamp wires through access hole in firebox as above Apply new sealant Mill Pac Secure Lamp Plate with screws Please follow the current ANSI NFPA 70 National Electrical Code in the USA and CAN CSA C22...

Страница 31: ...facing upward or sideways Replace burner tube and false bottom along with pilot shield STEP 4 Connect switch wires between lamp wire and transformer see schematic Connect remaining lamp wire to trans...

Страница 32: ...om inside of Firebox See Fig 2 at bottom of page 3 Remove screws from False Bottom and lift out of Firebox See Fig 1 below Installation of Porcelain MQRB3632 Liner Panels 1 Slide Side Panel s into pla...

Страница 33: ...ed OPTIONAL BACK AND SIDE BRICK PANEL INSTALLATIONS 1 Remove side brick clip located on top of firebox 2 Slide side brick panel into firebox through the small side opening and center from left to righ...

Страница 34: ...cedure VALVE REMOVAL AND REPLACEMENT 1 To remove Valve first follow Burner instructions 2 Remove GAS line and Deflector Pan 3 To remove Valve Pan first remove self tapping screws then using a knife sl...

Страница 35: ...ult your local authorities and the current CAN CGA B149 1 or 2 installation code in Canada or the National Fuel Gas code ANSI Z223 1 in the U S A Important Always check for gas leaks with a soap and w...

Страница 36: ...ay and hold it With the other hand push in the red ignitor button until you hear a click Now observe closely the pilot burner located on the rear center left hand side of the main burner If a flame ha...

Страница 37: ...ner was never on Exercise caution when working within the area ALL WORK SHOULD BE PERFORMED BY A QUALIFIED AND CERTIFIED TECHNICIAN Monthly Flame Inspection It is recommended to turn on the unit at le...

Страница 38: ...LP Conversion IPI 1001 P168SI 35 977 168 51 1000 P201VE HEX 1 4 1002 P014SI 0 907 014 31MDV CKNGI for MDVR31NE MDVL31NE NG Conversion IPI 1001 P166SI 62 977 166 36 1000 P201VE HEX 3 32 1002 P016SI 0 9...

Страница 39: ...th conversion kit 5 Adjust the primary air setting to the correct setting as specified in the manual or label plate To adjust air setting loosen screw on the side of air mixing tube and rotate to the...

Страница 40: ...e new injector is proper for the application The injector size is stamped on the side of the injector near the top LPG injectors have a groove machined around their circumference near the top while NG...

Страница 41: ...Gas Conversion for Modulator PART C WARNING WARNING 41...

Страница 42: ...the remote Contrary to this feature is a Manual HI LO Control Knob The Modulating Servo Motor requires the Remote system to be present Backup Battery Pack This component permits the IPI system to oper...

Страница 43: ...ol wiring harness instead of the main IPI harness From the Remote wiring harness use its male plug in connector and connect it to the female plug in in the main IPI harness Now the circuit is complete...

Страница 44: ...Configuration 1 Basic manual HI LO and manual ON OFF capabilities 44...

Страница 45: ...Receiver Module 584 523 521 221 1001 P221SI Receiver Module 584 523 521 221 1001 P221SI 45...

Страница 46: ...Receiver Module 584 523 521 221 1001 P221SI Receiver Module 584 523 521 221 1001 P221SI 46...

Страница 47: ...ent LIGHTING INSTRUCTIONS 1 STOP Read the above safety information on this label 2 Remove batteries from Receiver and or Battery Backup Pack 3 Turn off all electric power to the fireplace 4 This firep...

Страница 48: ...wall 24 inches 60 cm Recommended to prevent re circulation of exhaust products For additional requirements check local codes NOTE Clearances are to the edge of terminal plate add 6 3 4 to clearances...

Страница 49: ...uplers to extend short pipes Single sections OPTIONAL CLAMPS SEAL WITH HIGH TEMP SEALANT are preferred in an installation attaching at the fireplace and termina tion Place the spring spaces provided a...

Страница 50: ...wed 3 Vent table has been established for 90 horizontal vertical runs With use of flex pipe distance not having 90 bends will not fall into vent table standards See Fig B Venting Table From Bottom Of...

Страница 51: ...le enclosure 2 5 rise per ft for horizontal runs with min vertical from Fireplace For installations other than Low Profile Enclosures top of horizontal with no sleeve requires a 2 5 clearance and 4 0...

Страница 52: ...a fire stop is not required Roof Flashing Ensure that you have the proper roof flashing by checking your roof pitch using a level and two rulers or by using a roof pitch card See figure below Slide a...

Страница 53: ...6 3800 312 3800 132 3800 134 3800 302 3600 301 5000 P025WS 1000 150GE RED 1000 150MP BLACK 1000 218 Z1MT 3800 128 EMBER I EMBER R ZIRC 3800 173 3800 171 3800 172 3800 138 3800 127 3800 170 3600 115 38...

Страница 54: ...For Models MDV31 39 Replacement Parts continued 54...

Страница 55: ...ZDV48GP ZDV7SC ZDV4SS ZDVRS ZDV7FCL ZDVWT ZDVSS ZDVST ZDV7FC ZDV4FC ZDVAIS ZDVFS ZDVAAF ZDVAF2 ZDVAF3 ZDVFK5 ZDVFK8 ZDVFK20 FDVHT FDVVT40 Replacement Parts continued 55...

Страница 56: ...t See Through Polish Brass Two Sets MGSKAB Grill Kit See Through Antique Brass Two Sets MGSKCR Grill Kit See Through Chrome Two Sets Replacement Burner Assembly c w Valve 3100 BRNG Burner Assembly Rig...

Страница 57: ...e Two Sets MQ36SWFPW Wall Surround Pewter MQ36SWAKSB Wall Surround Accents Keystone Black MQ36SWAKSC Wall Surround Accents Keystone Chrome MQ36SWABBC Wall Surround Accents Bands Black x 4 Chrome x 2 M...

Страница 58: ...vory 1451 001 1000 227 Cover Ivory 86001 001 1000 255 Orifice Brass State Size 1000 EMBER Glowing Moon Rock 3800 134 Explosion Felt Gasket 2000 080 Thermodisc 2450 For Blower 2000 081 Blower Motor QLN...

Страница 59: ...itch If okay jumper wires across wall switch wires at valve If burner comes on wires are faulty or connec tions are bad Generator may not be Check generator with millivolt meter Take reading at genera...

Страница 60: ...n and other at risk individuals out of the room and away from hot surfaces Do not leave the fireplace remote control where it is accessible to children Termination Cap Safety All Units WARNING WHEN TH...

Страница 61: ...s other than in a normal residential environment c damages caused by any unauthorized alteration or repair of the unit affecting its stability or performance d damages caused by improper matching or a...

Отзывы: