Clearances – MDV31 – Mantels & Surrounds
Clearance to Combustibles
Back (of unit)
6 inches /152mm
Sides (of unit in framing)
6 inches /152mm
Vertical Pipe
1 inch /25mm
Back (from standoffs)
0 inches /0mm
Side (from standoffs)
0 inches /0mm
Floor
0 inches /0mm
Ceiling (from bottom of fireplace)
60 inches
/152.4cm
Top of Horizontal Pipe
2.5 inches / 64mm
Top Framing from Standoff
0 inches /0mm
Louvered Units Only
Top of 90° Bend No Sleeve, in Enclosure over
52”
4 inches /102mm
Bottom of Top Enclosure with Insulation
Sleeve
42 inches
/1067mm
In Low Profile Enclosures from 42” to 52”
Top of Horizontal Pipe in Enclosure without
Sleeve
12 inches /305mm
Top of Horizontal Pipe in Low Profile
Enclosure with Insulation Sleeve
2 inches 51mm
MDV31 With Clean View Kit
Top of 90° Bend No Sleeve, in enclosure over
81”
4 inches /102mm
Bottom of Top Enclosure with Insulation
Sleeve
60 inches
/152.4cm
Top of Horizontal Pipe in Enclosure with
insulation Sleeve
4 inches /102cm