background image

 

 

 

 

This Limited Lifetime Warranty applies only while the unit remains at the site of the original installation 
and  only  if  the  unit is  installed  inside  the  continental  United  States,  Alaska,  Hawaii,  and  Canada.  The 
warranty applies only if the unit is installed and operated in accordance with the printed instructions and 
in compliance with applicable installation and building codes and good trade practices. 

BASIC ONE YEAR WARRANTY 

During  the  first  year  after  installation,  we  will  provide  a  replacement  for  any  component  part  of  your  unit  found  to  be  defective  in 
materials  or  workmanship,  including  labour  costs.  Repair  work  requires  prior  approval  by  Kingsman,  labour  costs  are  based  on  a 
predetermined rate schedule and any repair work must be done through an authorized Kingsman dealer. 
(Excluded Components: Accent Light Bulbs, Gasketing and Paint) 

LIMITED LIFETIME WARRANTY 

The heat exchanger, combustion chamber and burner of every Kingsman product excluding the Outdoor Firepit are warranted again st 
materials or workmanship during the period the product is owned by the original owner. The part to be replaced must be returned to our 
distributor  in  exchange  for  the  replacement  part.  Any  labor,  material,  freight  and/or  handling  charges  associated  with  any  repair  or 
replacement pursuant to this Limited Lifetime Warranty will not be covered by this warranty.  

GENERAL TERMS 

In lieu of providing a replacement part, we may, at our option, provide the distributor's component purchase price from us or a credit 
equal to the 

distributor’s component purchase price from us toward the purchase of any new unit which we distribute. If a credit is given 

in lieu of a replacement part, the rating plate from the unit being replaced must be submitted on a warranty claim, and the unit being 
replaced must be made available to our distributor for disposition.  

In establishing the date of installation for any purpose, including determination of the starting date for the term of this Limited Lifetime 
Warranty, reasonable proof of the original installation date must be presented*, otherwise the effective date will be based upon the date 
of manufacture plus thirty (30) days.  

We  will not be  responsible for  and  you,  the  user,  will pay  for:  (a)  damages caused by  accident,  abuse,  negligence, misuse,  ri ot,  fire, 
flood, or Acts of God (b) damages caused by operating the unit where there is a corrosive atmosphere containing chlorine, fluorine, or 
any other damaging chemicals (other than in a normal residential environment) (c) damages caused by any unauthorized alteration or 
repair of the unit affecting its stability or performance (d) damages caused by improper matching or application of the unit or the unit's 
components  (e)  damages  caused  by  failing  to  provide  proper  maintenance  and  service  to  the  unit  (f)  any  expenses  incurred  for 
erecting, disconnecting or dismantling the unit (g) parts or supplies used in connection with service or maintenance (h) damage repairs, 
inoperation or inefficiency resulting from faulty installation or application (i) electricity or fuel costs or any increase in electricity or fuel 
cost whatsoever including additional or unusual use of supplemental electric heat.  

We shall not be liable for any incidental, consequential, or special damages or expenses in connection with any use or failure of this 
unit.  We  have  not  made  and  do  not  make  any  representation  or  warranty  of  fitness  for  a  particular  use  or  purpose,  and  there  is  no 
implied condition  of  fitness  for  a  particular  use  or  purpose. We make  no  express  warranties  except  as  stated  in  this  Limited  Lifetime 
Warranty.  No  one  is  authorized  to  change  this  Limited  Lifetime  Warranty  or  to  create  for  us  any  other  obligation  or  liability  in 
connections with this unit. Any implied warranties shall last for one year after the original installation. Some states and provinces do not 
allow the exclusion or limitation of incidental or consequential damages or do not allow limitations on how long an implied warranty or 
condition lasts, so the above limitations or exclusions may not apply to you. The provisions of this limited warranty are in  additions to 
and not a modification of or subtraction from any statutory warranties and other rights and remedies provided by law.  

Save  this  certificate.  It  gives  you  specific  legal  rights,  and  you  may  also  have  other  rights  which  may  vary  from  state  to  state  and 
province to province.  

In the event your unit needs servicing, contact your dealer or contractor who installed or serviced your unit. When requesting service, 
please have the model and serial number from each unit readily available. If your dealer needs assistance, the distributor is available 
for support and we, in turn support the distributor's efforts.  

Fill in the installation date and model and serial numbers of the unit in the space provided below and retain this limited warranty for your 
files.  

 

Model No. 

 

Serial No. 

 

Date installed 

 

 

Dealer or Contractor Name:  

 

*To receive advantage of your warranty, you must retain the original records that can establish the installation date of your unit. 

 

The Ultimate in Design, Engineering & Quality 

 

Содержание MDV31

Страница 1: ...reach your gas supplier call the fire department For Propane Horizontal installations the venting must be a minimum of one foot vertical off the flue before going horizontal Installation Instructions...

Страница 2: ...he installations e g marble tile and the adhesives used to adhere this product to the walls can react with heat and cause odours It is recommended that you burn your gas fireplace or stove for a minim...

Страница 3: ...r and Grill Installation 23 LOGC31 Placement Guidelines for Model MDV31 39 24 25 MQRSP7 Rock Support Platform and MQROCK1 for Models MDV31 39 26 27 Accessories Available for Skyline ZDVRB3622 Ribbon B...

Страница 4: ...the appliance 15 Installation and repair should be done by a qualified service person The appliance should be inspected before use and at least annually by a professional service person More frequent...

Страница 5: ...A 720 2005 Edition B A carbon monoxide detector shall be located in the room that houses the appliance or equipment and shall Be powered by the same electrical circuit as the appliance or equipment su...

Страница 6: ...32 625 TOP VIEW PENINSULA RIGHT CORNER TOP VIEW SEE THRU TOP VIEW 20 0 6 0 MIN MIN 6 0 ALL UNITS CAN BE VENTED VERTICAL MAX Horizontal Run With Required Vertical Run LEFT CORNERTOP VIEW LEFT CORNER T...

Страница 7: ...f are equipped with nailing tabs Level Fireplace and nail or screw into place NOTE For Low Profile Enclosure Refer to Low Profile Enclosure Section R H FIREPLACE SHOWN FRAMING DETAIL THROUGH Combustib...

Страница 8: ...wing Ember installation refer to Log Placement Section FACING MATERIAL INSTALLATION Facing material Example DRYWALL may be installed flush with top of Fireplace Side facing to be installed to standoff...

Страница 9: ...oad Bearing MIN 36 0 FIGURE 1 FIGURE 2 SEE THROUGH FIREPLACE SHOWN FIREPLACE ASSEMBLY 1 Mount Door Cover Figure 2 First apply a small bead of High Heat Silicone to door seal Mount Door and screw into...

Страница 10: ...MATERIAL INSTALLATION Facing material Example DRYWALL may be installed Flush with top of Fireplace Side facing to be installed to standoffs only NOTE This UNIT is not Load Bearing Gyprock Gyprock DRYW...

Страница 11: ...hrough With CVCK Enclosures For Propane Horizontal Installations the venting must be a minimum of one foot vertical off the flue before the elbow on any horizontal runs of one foot or greater This all...

Страница 12: ...s depends on valve and fireplace location on riser or upper floor Fireplace Assembly 1 Mount Door Cover First apply a bead of High Heat Silicone to door seal Mount Door Cover and screw into place maki...

Страница 13: ...Framing and Facing Requirements See Through with CVCK Clean View Circulating Kit Note When CVCK is used a CVCK Kit must be installed on Both sides of the unit MDV31 with MQ36SWF Surround 13...

Страница 14: ...supplied 6 screws fasten the CVCK to the inside posts of the appliance 5 Using ten 10 DT screws install the Top Heat Shield to the upper inside portion of the CVCK A side cut view is provided to illus...

Страница 15: ...upper portion of the Surround so that the Surround Ledge is resting on top of the CVCK Deflector Lip 3 Align the Mounting Screw Holes and fasten the Surround in place with the supplied screws 4 Attac...

Страница 16: ...to wall sleeve Refer to Low Profile Enclosure Section for additional information FRAMING DETAIL HORIZONTAL RUN WITH MIN VERTICAL RUN MIN 36 0 FIGURE 1 THROUGH COMBUSTIBLE WALL 11 0 11 0 42 0 MIN For C...

Страница 17: ...FACING MATERIAL INSTALLATION Facing material Example DRYWALL may be installed Flush with top of Fireplace Side facing to be installed to standoffs only DRYWALL 17...

Страница 18: ...ER MINIMUM HEIGHT OF 52 0 MUST BE MAINTAINED FOR PROPER CLEARANCES INSULATION SLEEVE IS NOT REQUIRED THIS WILL LEAVE A 4 0 MINIMUM CLEARANCE TO COMBUSTIBLE TOP For Propane Horizontal Installations the...

Страница 19: ...m Louvered Units Only Top of 90 Bend No Sleeve in Enclosure over 52 4 inches 102mm Bottom of Top Enclosure with Insulation Sleeve 42 inches 1067mm In Low Profile Enclosures from 42 to 52 Top of Horizo...

Страница 20: ...ver the front face of the fireplace No portion of grill area or door areas can be covered except where designer Clean View Kit is used Combustible material can extend flush to the unit up to the top b...

Страница 21: ...ottom pan Refer to diagram for proper location Power cable to be routed through 6 x8 access hole 4 Connect power sensor and variable speed wall switch as shown in wiring diagram SUGGESTED LOCATION FOR...

Страница 22: ...pronged grounding plug for your protection against shock hazard and should be plugged directly into a properly grounded three prong receptacle Label all wires prior to disconnection when servicing con...

Страница 23: ...in both ends To install slide the head into one of the teardrop slots then slide Grill to opposite side repeat procedure These screws may have to be adjusted for proper alignment and length 3 All Gri...

Страница 24: ...rate bar Step 3 Locate mounting hole bottom of Log 3 onto Tab 3a and have char area touch Tab 3b TAB 3a TAB 3b TAB 4a TAB 4b TAB 2a GRATE BAR EMBER PLATES EMBERS ROCK FLAT AREA NOTCH NOTCH GRATE BAR T...

Страница 25: ...o grate bar and rest log onto flat area of Log 2 Step 6 Position Log 6 up against Logs 4 and 5 and place flat area of log on floor of fire box Step 7 Locate notched areas of Logs 2 and 3 and place Log...

Страница 26: ...ner tube Step 2 Place rocks 6 into position as shown Step 3 Place rocks 4 into position as shown Using the 2 4 s highlighted place them over the single porting crossover area as shown MQRSP7 Rock Supp...

Страница 27: ...is high lighted over the single porting crossover area as shown Step 7 Place rock 1 into position as shown Finished setup and burn If too much flame impingement on the rocks causes sooting you may ha...

Страница 28: ...en placing glass embers near the pilot area so as not block or have the glass fall over the crossover holes from the pilot to the burner as delayed ignition can occur The following types of glass are...

Страница 29: ...Embers may be used with or without other accessories ULK2 UNIVERSAL LIGHT KIT Optional Accent Lighting Kit See separate installation page NOTE Pilot Area Must Not Be Covered as delayed ignition can o...

Страница 30: ...t lamp wires through access hole in firebox as above Apply new sealant Mill Pac Secure Lamp Plate with screws Please follow the current ANSI NFPA 70 National Electrical Code in the USA and CAN CSA C22...

Страница 31: ...facing upward or sideways Replace burner tube and false bottom along with pilot shield STEP 4 Connect switch wires between lamp wire and transformer see schematic Connect remaining lamp wire to trans...

Страница 32: ...om inside of Firebox See Fig 2 at bottom of page 3 Remove screws from False Bottom and lift out of Firebox See Fig 1 below Installation of Porcelain MQRB3632 Liner Panels 1 Slide Side Panel s into pla...

Страница 33: ...ed OPTIONAL BACK AND SIDE BRICK PANEL INSTALLATIONS 1 Remove side brick clip located on top of firebox 2 Slide side brick panel into firebox through the small side opening and center from left to righ...

Страница 34: ...cedure VALVE REMOVAL AND REPLACEMENT 1 To remove Valve first follow Burner instructions 2 Remove GAS line and Deflector Pan 3 To remove Valve Pan first remove self tapping screws then using a knife sl...

Страница 35: ...ult your local authorities and the current CAN CGA B149 1 or 2 installation code in Canada or the National Fuel Gas code ANSI Z223 1 in the U S A Important Always check for gas leaks with a soap and w...

Страница 36: ...ay and hold it With the other hand push in the red ignitor button until you hear a click Now observe closely the pilot burner located on the rear center left hand side of the main burner If a flame ha...

Страница 37: ...ner was never on Exercise caution when working within the area ALL WORK SHOULD BE PERFORMED BY A QUALIFIED AND CERTIFIED TECHNICIAN Monthly Flame Inspection It is recommended to turn on the unit at le...

Страница 38: ...LP Conversion IPI 1001 P168SI 35 977 168 51 1000 P201VE HEX 1 4 1002 P014SI 0 907 014 31MDV CKNGI for MDVR31NE MDVL31NE NG Conversion IPI 1001 P166SI 62 977 166 36 1000 P201VE HEX 3 32 1002 P016SI 0 9...

Страница 39: ...th conversion kit 5 Adjust the primary air setting to the correct setting as specified in the manual or label plate To adjust air setting loosen screw on the side of air mixing tube and rotate to the...

Страница 40: ...e new injector is proper for the application The injector size is stamped on the side of the injector near the top LPG injectors have a groove machined around their circumference near the top while NG...

Страница 41: ...Gas Conversion for Modulator PART C WARNING WARNING 41...

Страница 42: ...the remote Contrary to this feature is a Manual HI LO Control Knob The Modulating Servo Motor requires the Remote system to be present Backup Battery Pack This component permits the IPI system to oper...

Страница 43: ...ol wiring harness instead of the main IPI harness From the Remote wiring harness use its male plug in connector and connect it to the female plug in in the main IPI harness Now the circuit is complete...

Страница 44: ...Configuration 1 Basic manual HI LO and manual ON OFF capabilities 44...

Страница 45: ...Receiver Module 584 523 521 221 1001 P221SI Receiver Module 584 523 521 221 1001 P221SI 45...

Страница 46: ...Receiver Module 584 523 521 221 1001 P221SI Receiver Module 584 523 521 221 1001 P221SI 46...

Страница 47: ...ent LIGHTING INSTRUCTIONS 1 STOP Read the above safety information on this label 2 Remove batteries from Receiver and or Battery Backup Pack 3 Turn off all electric power to the fireplace 4 This firep...

Страница 48: ...wall 24 inches 60 cm Recommended to prevent re circulation of exhaust products For additional requirements check local codes NOTE Clearances are to the edge of terminal plate add 6 3 4 to clearances...

Страница 49: ...uplers to extend short pipes Single sections OPTIONAL CLAMPS SEAL WITH HIGH TEMP SEALANT are preferred in an installation attaching at the fireplace and termina tion Place the spring spaces provided a...

Страница 50: ...wed 3 Vent table has been established for 90 horizontal vertical runs With use of flex pipe distance not having 90 bends will not fall into vent table standards See Fig B Venting Table From Bottom Of...

Страница 51: ...le enclosure 2 5 rise per ft for horizontal runs with min vertical from Fireplace For installations other than Low Profile Enclosures top of horizontal with no sleeve requires a 2 5 clearance and 4 0...

Страница 52: ...a fire stop is not required Roof Flashing Ensure that you have the proper roof flashing by checking your roof pitch using a level and two rulers or by using a roof pitch card See figure below Slide a...

Страница 53: ...6 3800 312 3800 132 3800 134 3800 302 3600 301 5000 P025WS 1000 150GE RED 1000 150MP BLACK 1000 218 Z1MT 3800 128 EMBER I EMBER R ZIRC 3800 173 3800 171 3800 172 3800 138 3800 127 3800 170 3600 115 38...

Страница 54: ...For Models MDV31 39 Replacement Parts continued 54...

Страница 55: ...ZDV48GP ZDV7SC ZDV4SS ZDVRS ZDV7FCL ZDVWT ZDVSS ZDVST ZDV7FC ZDV4FC ZDVAIS ZDVFS ZDVAAF ZDVAF2 ZDVAF3 ZDVFK5 ZDVFK8 ZDVFK20 FDVHT FDVVT40 Replacement Parts continued 55...

Страница 56: ...t See Through Polish Brass Two Sets MGSKAB Grill Kit See Through Antique Brass Two Sets MGSKCR Grill Kit See Through Chrome Two Sets Replacement Burner Assembly c w Valve 3100 BRNG Burner Assembly Rig...

Страница 57: ...e Two Sets MQ36SWFPW Wall Surround Pewter MQ36SWAKSB Wall Surround Accents Keystone Black MQ36SWAKSC Wall Surround Accents Keystone Chrome MQ36SWABBC Wall Surround Accents Bands Black x 4 Chrome x 2 M...

Страница 58: ...vory 1451 001 1000 227 Cover Ivory 86001 001 1000 255 Orifice Brass State Size 1000 EMBER Glowing Moon Rock 3800 134 Explosion Felt Gasket 2000 080 Thermodisc 2450 For Blower 2000 081 Blower Motor QLN...

Страница 59: ...itch If okay jumper wires across wall switch wires at valve If burner comes on wires are faulty or connec tions are bad Generator may not be Check generator with millivolt meter Take reading at genera...

Страница 60: ...n and other at risk individuals out of the room and away from hot surfaces Do not leave the fireplace remote control where it is accessible to children Termination Cap Safety All Units WARNING WHEN TH...

Страница 61: ...s other than in a normal residential environment c damages caused by any unauthorized alteration or repair of the unit affecting its stability or performance d damages caused by improper matching or a...

Отзывы: