ZCV39 / ZCV42
Log C3 / F3
NOTE: Set Primary Air Opening at 1/8” for Natural Gas.
Refer to Gas Conversion and Burner Removal sections in manual.
*These items are supplied with the fireplace.
Pull up [4] Log Tabs on Burner.
Match with Holes in Logs 3 & 4.
Log 1
is placed against back wall of firebox.
Log 2
is placed against
left
back wall of firebox.
Log 3
is placed on
right
side Log Tabs.
Log 4
is placed on
left
side Log Tabs.
Log 5
is placed against
right
back wall of firebox.
⚠
WARNING:
Failure to position the parts in accordance with these diagrams or failure to use only parts
specifically approved with this appliance may result in property damage or personal injury.
*Embers
*Lava Rock
*Vermiculite
5
4
2
Pull Up [4] Log Tabs
Embers, Lava Rock &
Insulation Wool on Burner
*Insulation Wool
Lava Rock & Vermiculite
on Firebox Bottom
1
3
1
2
3
4
5
44
Содержание marquis ZCV39LPE2
Страница 62: ...Gas Conversion for Modulator PART C 62...
Страница 67: ...Configuration 1 Basic manual HI LO and manual ON OFF capabilities 67...
Страница 68: ...Receiver Module 584 523 521 221 1001 P221SI Receiver Module 584 523 521 221 1001 P221SI 68...
Страница 75: ...Proflame 2 Remote Control 75...