ZCV42 Clearance to Combustibles
Clearance to Combustibles ZCV42
Front
36” [92cm]
Back (from Stand-offs)
0” [0cm]
Side (from Stand-offs)
0” [0cm]
Floor
*
0” [0cm]
Minimum Ceiling Height (from bottom of fireplace)
59.5” [151cm]
Top (from Stand-offs)
0” [0cm]
Top of 90° Bend in minimum Enclosure of
59.5”
3-
1/2” [8.9]
Top of 90° Bend in Enclosure over
59.5”
3-
1/2” [8.9]
VENTING SYSTEMS
Top of Horizontal Pipe
1/1/2” [3.8cm]
Side & Bottom of Horizontal Pipe
1” [2.5cm] All Vent Systems
Vertical Vent Pipe
1” [2.5cm] All Vent Systems
*Note: If appliance is installed directly on
carpeting or other combustible material
other than wood flooring, a metal or wood
panel extending the full width and depth of
the appliance must be used. Carpet may
extend 1 inch above the floor of the
appliance.
52-
1/2” MIN for NG
64-
1/2” MIN for LP
Plus Rise of 1/4”
Per Foot*
18