background image

 

- Installation Instructions - 

 

 

 

 

             

 

 

 

 

 

 

 

-Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other 
appliance

-WHAT TO DO IF YOU SMELL GAS

 

  Do not try to light any appliance. 

  Do not touch any electrical switch; do not use any phone in your building. 

  Leave the building immediately. 

 

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s 
instructions. 

  If you cannot reach your gas supplier, call the fire department 

-Installation and service must be performed by a qualified installer, service agency or the gas 
supplier.

 

INSTALLER: 

Leave this manual with the appliance.  

CONSUMER: 

Retain this manual for future reference. 

This appliance may be installed in an aftermarket, permanently located, manufactured home (USA only) or mobile home, 
where not prohibited by local codes. 

This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use 
with other gases, unless a certified kit is used.

 

Model Numbers: 

MQZCVBG34NE2, MQZCVBG34LPE2 

Certified to: 

CSA/ANSI Z21.88:19 • CSA 2.33:19 
and CSA2.17-2017 

VENTED GAS FIREPLACE HEATERS 

A Division of R-Co. Inc. 2340 Logan Ave. 

  Winnipeg, Manitoba Canada R2R 2V3 Ph.: (204) 632-1962 

Printed in Canada April 5, 2022 Part# 34ZCVBG-MAN19 

VENTED GAS FIREPLACE HEATER:

 

NOT FOR USE WITH SOLID FUEL

 

 

ENCLAVE 

 WARNING:  

FIRE OR EXPLOSION HAZARD

 

Failure to follow safety warnings exactly could result in serious injury, death, or property damage. 

 

WARNING:

 

do not operate this appliance without decorative glass embers on burner and media tray.

 

Содержание MQZCVBG34LPE2

Страница 1: ...appliance may be installed in an aftermarket permanently located manufactured home USA only or mobile home where not prohibited by local codes This appliance is only for use with the type of gas indic...

Страница 2: ...to keep toddlers young children and other at risk individuals out of the room and away from hot surfaces Do not leave the fireplace remote control where it is accessible to children WARNING A HORIZON...

Страница 3: ...17 Framing Dimensions Recessed Front and Side Chase Open Top 18 Framing Dimensions Corner Framing Full Chase with Open Top 19 Framing Dimensions Corner Framing Recessed Front Chase with Open Top 20 F...

Страница 4: ...Modulator 58 Burner System Removal and Installation 59 Lighting Instructions IPI 60 Proflame 2 IPI System Parts List 61 Proflame 2 IFC Module and Remote Control 62 Cold Climates CPI Setting 63 Proflam...

Страница 5: ...due to excessive lint from carpeting bedding material et cetera It is imperative that control compartments burners and circulating air passageways of the appliance be kept clean Make sure that the ga...

Страница 6: ...ication plate shall be mounted at the exterior of the building four feet directly above the location of vent terminal The plate shall be of sufficient size to be easily read from a distance of eight f...

Страница 7: ...sounds produced by a furnace or heating duct This noise does not affect the operation or longevity of your fireplace It is also normal for the fan to make some noise when it comes on This noise can be...

Страница 8: ...mal shock Take care to prevent water from contacting the fireplace especially if it is hot See Through Units are suitable for an outdoor location but not on the outside wall of a house or other struct...

Страница 9: ...dian National Electrical Code in Canada An appliance must be grounded to the steel chassis of the home with 8 ga copper wire using a serrated or star washer to penetrate paint or protective coating to...

Страница 10: ...In USA see local codes Stand off and Nailing Tab Locations Make note of where the stand off locations are These stand offs are provided as indicators to illustrate the boundaries for framing Therefor...

Страница 11: ...Nailing Tabs are located on each side of the front frame These Nailing Tabs are used to attach the appliance to framing Pull up 90 for wall flush with fireplace face Rotate 180 for framing flush with...

Страница 12: ...sland installation with a top vent is possible as long as the horizontal portion of the vent system does not exceed 20 feet 6 1 m MQZCVBG34 Bay Peninsula Fireplace Dimensions A B C F 20 MAX 20 MAX G D...

Страница 13: ...CSA C22 1 Canadian Electrical Code or the National Electrical Code ANSI NFPA 70 when installed in the United States If using insulation in vented chase i e for outside wall wall board drywall is requ...

Страница 14: ...Vent Termination See Installation of Side Wall Venting Section RIGHT SIDE Note Orientation of 2x4 s This will provide the correct opening widths for Side or Front Grills 8 MIN from top of pipe to encl...

Страница 15: ...t Termination See Installation of Side Wall Venting Section No loose Combustibles wood wiring etc are allowed inside the open Chase area RIGHT SIDE Top of Chase Open on 3 Sides TOP OF CHASE OPEN ON 3...

Страница 16: ...o loose Combustibles wood wiring etc are allowed inside the open Chase area RIGHT SIDE Note Orientation of 2x4 s This will provide the correct opening width for Front Grill Unit and Framing can be cov...

Страница 17: ...ion of Side Wall Venting Section No loose Combustibles wood wiring etc are allowed inside the open Chase area RIGHT SIDE 2 1 4 From Ceiling or Top of Enclosure Top of Chase Open on 3 Sides Top of Chas...

Страница 18: ...tures are not load bearing Framing for Horizontal Vent Termination See Installation of Side Wall Venting Section No loose Combustibles wood wiring etc are allowed inside the open Chase area RIGHT SIDE...

Страница 19: ...are not load bearing Framing for Horizontal Vent Termination See Installation of Side Wall Venting Section No loose Combustibles wood wiring etc are allowed inside the open Chase area LEFT SIDE Unit...

Страница 20: ...ad bearing Framing for Horizontal Vent Termination See Installation of Side Wall Venting Section No loose Combustibles wood wiring etc are allowed inside the open Chase area LEFT SIDE Unit and Framing...

Страница 21: ...low to secure the enclosure NOTE These structures are not load bearing Framing for Horizontal Vent Termination See Installation of Side Wall Venting Section No loose Combustibles wood wiring etc are a...

Страница 22: ...placed immediately below the fireplace opening An Adjacent Side Wall may project directly from the side of the fireplace opening 72 Minimum Ceiling Enclosure Top 29 1 16 Bottom of Unit to Top of Open...

Страница 23: ...All Vent Systems Vertical Vent Pipe in Enclosure over 76 1 2 5cm All Vent Systems Wall Thimble or Attic Insulation Shield outside of barrel 0 0cm Top opening of Chase must be flush with Enclosure Top...

Страница 24: ...ets Minimum Opening Air Free Requirements Required Opening Dimensions 31 3 8 wide x 3 1 4 tall x 1 3 4 deep Outer Trim Dimensions 32 5 16 wide x 4 3 8 tall Installation Insert Grill into opening and f...

Страница 25: ...aint Grills must be installed on both sides of chase Required Opening Dimensions 10 1 4 wide x 4 13 16 tall Outer Trim Dimensions 11 1 4 wide x 6 tall Installation Insert Grills into openings and fast...

Страница 26: ...2 1 8 Gap at top of enclosure for Open Top chases Do not drive screws into these highlighted areas Do not drive screws into fireplace front Facing materials must be attached to framing FRONT A Tile L...

Страница 27: ...Fireplace Outer Cover 90ml Tube Millpac Qty 24 1 2 DT Screws Qty 6 Pan Head Screws Sheet Metal Components STEP ONE PREPARATION A Remove Front Firebox Glass B Remove the Side Door Retainers Firebox Si...

Страница 28: ...ill Pac are sealed against the side of the firebox Front Glass Gasket must be flush with front of firebox G Starting with the top 3 holes attach the Firebox Cover with 12 DT Screws Seal Gasket 3 8 Bea...

Страница 29: ...Set Stand Off in position and attach with DT Screw FRONT GLASS COVER K Install Front Firebox Glass L Install Front Glass Cover FRAMING Refer to Corner Framing Section of manual H Install Inner Liner P...

Страница 30: ...lly finger tighten wing nuts on Side Glass and then back them off 1 4 to 1 2 turn Finally finish tightening all wing nuts on Glass Front NOTE Do not over tighten nuts as glass could break Wingnuts sho...

Страница 31: ...ass Panel is installed 3 Proceed to Front Glass Installation Instruction Glass 34ZCVBG 311 Spring Mechanism 60VLBG 126A Replacement Part Spring Mechanism 60VLBG 126A Glass Door Frame c w Gasket SIDE G...

Страница 32: ...Suction Cups Recommended Removal of the Glass Front Refer to Glass Door Front Removal Installation section of this manual 1 Remove nuts with a 3 8 wrench 2 Remove Glass Door Removal of the Glass Side...

Страница 33: ...lass into clips in top of fireplace Bottom of glass will rest in Glass Supports THIS SIDE OUT etching must face outward TOP SIDE GLASS PANELS QTY 2 TOP FRONT GLASS PANEL QTY 1 INSERT GLASS INTO CLIPS...

Страница 34: ...serted removed from beneath fireplace through access panel opening Remove glass door first Battery Backup Proflame 2 Module Component Box Valve Lamp Transformer Receptacle Receptacle Valve Lamp Transf...

Страница 35: ...t Bottom Tile Lip 34 7 16 2 2 34ZCV TLK2 Side Horizontal Tile Lip 14 7 16 3 2 34ZCV TLK3 Side Vertical Tile Lip 21 5 8 4 23 530 685 8 1 2 Self Tapping Screw Items 5 6 are supplied with Fireplace 5 1 3...

Страница 36: ...with wire connectors Millivolt P1 Only Light Switch Cover Plate c w10ft wire c w 1 Loose Female 1 Loose Male wire connector Inside Firebox Bottom of Firebox Connect Switch Here for Millivolt Proflame...

Страница 37: ...fusion when connecting wires to Lamp Plate in Step 5 STEP 5 Take wires from rear bottom of firebox and CONNECT ONE TO EACH STUD ON LAMP PLATE Repeat Steps 4 and 5 for the second Lamp Assembly Lamp Ass...

Страница 38: ...from Corner Kit CONTENTS 3 GLASS BACK LINERS BACK CLIP DISCARD CAUTION NOT TEMPERED GLASS EXTREMELY FRAGILE HANDLE WITH CARE STEP ONE Remove Liner Clip and screws from inside of firebox with a 1 4 hex...

Страница 39: ...TEMPERED GLASS EXTREMELY FRAGILE HANDLE WITH CARE NOTE If using CORNER KIT and you are NOT installing a Glass Side Liner install Inner Liner Panel from Corner Kit before Glass Back Liner However if yo...

Страница 40: ...ws NOTE Install Back Liner Before installing Side Liner CONTENTS 1 BACK LINER CENTER CLIP STEP ONE Remove Brick Liner Clips and screws from inside of firebox with a 1 4 hex driver KEEP DT SCREWS LOWER...

Страница 41: ...R KIT and you are NOT installing a Side Liner install Inner Liner Panel from Corner Kit before Back Liner However if you ARE installing a Side Liner do not install Inner Liner Panel from the Corner Ki...

Страница 42: ...ck MQG5ZG Decorative Glass Zircon Glacier Ice MQG5C Decorative Glass Bronze The following types of glass are approved Kingsman Decorative Glass Ember Glass Material from American Fireglass Decorative...

Страница 43: ...can be placed on or around Burner Lava Rock is supplied with Base Unit Do not place directly onto Burner Place Stones onto False Bottom and Burner Do not place directly on burner ports or Pilot Area N...

Страница 44: ...tly on Burner and on Glass Tray Maximum 5 LBS of Glass MQ Ember can be placed directly on Burner Only Lava Rock Supplied with Base Unit CANNOT be placed on Burner Place Lava Rock in channel in front o...

Страница 45: ...n accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury NOTE Lava Rock and 350 Embers supplied with fir...

Страница 46: ...k MQ Stone or MQ Ember Follow instructions for these accessories LOG 2 LOG 5 LOG 3 LOG 4 LOG 1 NOTE For best flame pattern it is essential to spread supplied Crushed Glass or MQEMBER directly onto bur...

Страница 47: ...lot area must not be covered as delayed ignition could occur For best flame pattern it is essential to spread supplied Crushed Glass or MQEMBER directly onto burner tube If sooting occurs one or more...

Страница 48: ...d with this appliance may result in property damage or personal injury NOTE THESE ITEMS ARE SUPPLIED WITH THE FIREPLACE LOG 1 LOG 2 LOG 3 LOG 4 LOG 5 LOG 6 Lava Rock Embers Insulation Wool LOG 3 LOG 5...

Страница 49: ...r more logs may be removed WARNING Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage...

Страница 50: ...r more logs may be removed WARNING Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage...

Страница 51: ...MQLOGF34BW MQLOGF34OAK Setup Instructions 1 2 Pull up Log Tabs for Log 3 Set Log 3 onto Tabs on Burner Place Embers and Insulation Wool on Burner Place Lava Rock beside burner 4 5 6 7 51...

Страница 52: ...ly piping system during any pressure testing of that system at test pressures in excess of 1 2 PSIG 3 5 KPa 9 The appliance must be isolated from the gas supply piping system by closing its individual...

Страница 53: ...condition of vent and vent terminal for sooting or obstruction and correct if present 6 Vacuum and clean any debris in the firebox that is not supposed to be there 7 Test and measure the flame failure...

Страница 54: ...as valve Should read 325 millivolts minimum while holding valve knob depressed in pilot position and wall switch off Replace faulty generator if reading is below specified minimum Plugged burner orifi...

Страница 55: ...tanding pilot system even if the main burner was never on Exercise caution when working within the area ALL WORK SHOULD BE PERFORMED BY A QUALIFIED AND CERTIFIED TECHNICIAN Monthly Flame Inspection It...

Страница 56: ...ulator by following instructions supplied with the Conversion Kit Refer to Gas Specifications Chart for inlet pressures and input ratings Clock meter to verify input rate Place conversion label as clo...

Страница 57: ...njector near the top Propane injectors have a groove machined around their circumference near the top while NG injectors do not have a groove fig 4 Refer to the Appliance Manufacturer s instruction sh...

Страница 58: ...Gas Conversion for Modulator PART C 58...

Страница 59: ...to remove it from the firebox cavity Burner System Installation is the reverse of these steps Ensure that the mounting surface is clean Use fresh Black Mill Pac to reseal the burner pan WARNING Turn o...

Страница 60: ...ctric power to the appliance 4 This appliance is equipped with an ignition device which automatically lights the pilot Do not try to light the pilot by hand 5 Wait five 5 minutes to clear out any gas...

Страница 61: ...I TC Pilot Burner IPI Assembled NG 199 033 14 1002 P047SI TC Pilot Burner IPI Assembled LP 199 047 15 1001 P166SI TC Orifice Pilot NG 977 166 62 IPI 16 1001 P168SI TC Orifice Pilot LP 977 168 35 IPI 1...

Страница 62: ...s required The following sequence must be followed to reset the PF2 Module Press the Red SW1 button until you hear three beeps Within 10 seconds press the SW1 button again until you hear it beep The P...

Страница 63: ...the main burner has been cycled ON OFF and the pilot is also out follow the procedures described in this manual to light the pilot To switch from IPI to CPI Mode 1 Turn the fireplace OFF using the ON...

Страница 64: ...Proflame 2 Remote Control 64...

Страница 65: ...Smart Thermostat is activated manual flame height adjustment is disabled Note This function is only available in Room Thermostat or Smart Thermostat Control Mode Halogen lights only FAN OPTION NOT AVA...

Страница 66: ...FAN OPTION NOT AVAILABLE 66...

Страница 67: ...nlet 6 ft 1 83 m 3 ft 91 cm above if within 10 ft 3 m horizontally L Clearance above paved sidewalk or paved driveway located on public property 7 ft 2 13 m Notes 2 M Clearance under veranda porch dec...

Страница 68: ...See Fig 1 Horizontal runs require support metal straps every 2 feet In offset installation support straps should be used to stabilize pipe Expand 5 and 8 flex pipe to the point that the 8 protrudes a...

Страница 69: ...nt termination and seal to wall using caulking around the wall thimble to weather proof After installing the vent termination double check to make sure the pipe extends properly through wall thimble a...

Страница 70: ...termine the height of the system and the number of bends required 2 Having determined the vertical distance determine the maximum horizontal section allowed 3 Vent table has been established for 90 ho...

Страница 71: ...ecessary to use the Flue Restrictor The Flue Restrictor is set fully open from the factory for short horizontal and vertical runs INSIDE TOP OF FIREBOX To adjust the Flue Restrictor remove DT Screws f...

Страница 72: ...suitable to your roof slope over the vent Place the edge of the flashing plate that will be on the higher part of the roof slope under the shingles Both the sides and the lower edge lay on top of the...

Страница 73: ...of support configuration B Flex bend configuration C Termination mounting A B C 24 Clearance to adjacent or perpendicular wall is 24 inches 60 cm Recommended to prevent re circulation of exhaust produ...

Страница 74: ...ng on 3 Sides Z58FS Firestop MIN 1 Clearance to Vertical Vent Z58FS Firestop Hole may need to be elongated to due to ceiling angle Trim to 12 to match chase depth if necessary Z58AIS24 or Z58AIS Attic...

Страница 75: ...MININMUM VENT HEIGHT IS 12 FEET MAXIMUM VENT HEIGHT IS 43 FEET HIGH WIND TERMINATION CAP 46DVA VCH FLEX LINER IDVVT43 CO LINEAR TERMINATION SEAL PLATE STANDARD VERTICAL TERMINATION CAP 46DVA VC 46DVA...

Страница 76: ...ent Lengths using Power Vents Minimum Vent Length is 4 FT vertical x 6 FT horizontal with up to 5 elbows Maximum Vent Length for 5 8 Flex Pipe is 7FT vertical x 125FT horizontal with up to 5 elbows Ma...

Страница 77: ...CER 5 8 to 3 5 ADAPTER used at flue of fireplace Requires a one foot section of MG Hard Pipe at flue before using PVA5835 PVA3558 Termination End Duravent Pipe Increaser at Power Vent SECTION 3 DIRECT...

Страница 78: ...Decorative Glass 1 2 White 5LB MQG5A Decorative Ember Glass Cobalt Blue 5LB MQG5B Decorative Ember Glass Black 5LB MQG5ZG Decorative Glass Zircon Glacier Ice 5LB MQG5C Decorative Glass Bronze 5LB MQR...

Страница 79: ...Return Z58GP Galvanized Pipe 8 Dia x 48 Vertical Installations Z58MIS60 Mylar Insulation Sleeve 8 x 5ft Z58AAF Flashing 8 c w Storm Collar 1 12 to 7 12 Z58AF2 Flashing 8 c w Storm Collar 8 12 to 12 1...

Страница 80: ...hemicals other than in a normal residential environment c damages caused by any unauthorized alteration or repair of the unit affecting its stability or performance d damages caused by improper matchi...