![Kinghome KW09CQ2B8A Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/kinghome/kw09cq2b8a/kw09cq2b8a_service-manual_1970319010.webp)
7
Technical Information
Service Manual
Outdoor Unit
Model of Outdoor Unit
KW09CQ2B8AO
KW12CQ2B8AO
Outdoor Unit Product Code
CB419W03800_L74316
CB419W04000_L74316
Compressor Manufacturer/Trademark
ZHUHAI GREE DAKIN DEVICE
CO.,LTD.
ZHUHAI GREE DAKIN DEVICE
CO.,LTD.
Compressor Model
QXA-A091zE190
QXA-A091zE190
Compressor Oil
FVC68D or RB 68EP
FVC68D or RB 68EP
Compressor Type
Rotary
Rotary
Compressor Locked Rotor Amp (L.R.A)
A
/
/
Compressor RLA
A
8.63
12.5
Compressor Power Input
W
980
980
Overload Protector
1NT11L-6233 or KSD115
O
C or
HPC115/95U1
1NT11L-6233 or KSD115
O
C or
HPC115/95U1
Throttling Method
Electron expansion valve
Electron expansion valve
Operation temp
ºF
61~86
61~86
Ambient temp (cooling)
ºF
0~115
0~115
Ambient temp (heating)
ºF
/
/
Condenser Form
Aluminum Fin-copper Tube
Aluminum Fin-copper Tube
Pipe Diameter
inch
Φ3/8
Φ3/8
Rows-fin Gap
inch
2-1/18
2-1/18
Coil Length (LXDXW)
inch
30 43/64X1 47/64X20
30 43/64X1 47/64X22
Fan Motor Speed
rpm
850
850
Output of Fan Motor
W
30
30
Fan Motor RLA
A
0.55
0.55
Fan Motor Capacitor
μF
/
/
Air Flow Volume of Outdoor Unit
CFM
1059
1177
Fan Type
Axial-flow
Axial-flow
Fan Diameter
inch
Φ15 3/4
Φ15 3/4
Defrosting Method
/
/
Climate Type
T1
T1
Isolation
I
I
Moisture Protection
IPX4
IPX4
Permissible Excessive Operating
Pressure for the Discharge Side
MPa
4.3
4.3
Permissible Excessive Operating
Pressure for the Suction Side
MPa
2.5
2.5
Sound Pressure Level (H/M/L)
dB (A)
53/-/-
53/-/-
Sound Power Level (H/M/L)
dB (A)
63/-/-
63/-/-
Dimension (WXHXD)
inch
33 3/8X21 1/4X12 5/8
33 3/8X21 1/4X12 5/8
Dimension of Carton Box (LXWXH)
inch
34 9/16X14 3/16X22 13/16
34 9/16X14 3/16X22 13/16
Dimension of Package (LXWXH)
inch
34 11/16X14 5/16X23 7/16
34 11/16X14 5/16X23 7/16
Net Weight
Ib
62.83
73.85
Gross Weight
Ib
68.34
80.47
Refrigerant
R410A
R410A
Refrigerant Charge
oz
42.34
47.62
Connection
Pipe
Length
ft
24.6
24.6
Gas Additional Charge
oz/ft
0.2
0.2
Outer Diameter Liquid Pipe
inch
Φ1/4
Φ1/4
Outer Diameter Gas Pipe
inch
Φ3/8
Φ1/2
Max Distance Height
ft
32.8
32.8
Max Distance Length
ft
49.2
65.6
Note:The connection pipe applies metric diameter.
The above data is subject to change without notice. Please refer to the nameplate of the unit.
Содержание KW09CQ2B8A
Страница 1: ...Service Manual...
Страница 78: ...75 Technical Information Service Manual AUTO COOL DRY FAN HEAT OFF...
Страница 80: ...77 Technical Information Service Manual battery Cover of battery box remove reinstall...
Страница 176: ...173 Installation and Maintenance Service Manual...
Страница 202: ...JF00304217...