Revision 7 Date: 22 Jun 2020 Page 9 of 13
Choose a threshold group number (from the available 01, 02, 03) using [▲,
▼].
Press [OK] to activate Pass/Fail display mode.
Press and hold [OK] to de-activate Pass/Fail display mode.
3.8 Setting Time
At Home Display, press and hold [►] to enter Time Setting mode.
Use [◄, ►] to select digit to be edited; the selected digit will blink. Use [▲,
▼] to edit the value of the selected digit. Press [OK] to save changes or press
[OFF] to exit Time Setting mode without saving.
Date format: YY/MM/DD
Time format: HH:MM
Time Setting mode will exit automatically if no subsequent key is pressed 10
sec after it was selected.
3.9 Save, Retrieve/view, Delete Test Data
To save data:
At Home Display, press [F1]; the blinking symbol, “ ” indicates that
instrument is in
Data Saving mode
.
Press [OK] to save existing test data onto internal memory or press [OFF] to
exit without saving.
Data Saving Mode will exit automatically if no subsequent key is pressed 10
sec after being selected. A max of 99 records can be saved.