Kingfisher KI6102 Series Скачать руководство пользователя страница 3

 

 

Revision 7                                         Date: 22 Jun 2020                                                                                          Page 3 of 13 

1.  Technical specifications 

 

 

.  

 

 

Standard wavelengths 

1310 

(upstream test) 

1490 

(downstream test) 

1550 

(downstream test) 

Pass zone(nm) 

1260 

 1360 

1470 

 1505 

1535 

 1570 

Range(dBm) 

-40 

 +10 

-45 

 +10 

-45 

 +23 

Isolation @1310nm(dB) 

 

> 40 

> 40 

Isolation @1490nm(dB) 

> 40 

 

> 40 

Isolation @1550nm(dB) 

> 40 

> 40 

 

Uncertainty(dB) 

±0.5 

Polarization Dependent 
Loss (dB) 

< ±0.25 

Linearity(dB) 

±0.1 

Through Insertion 
Loss(dB) 

< 1.5 

Resolution 

0.01dB 

Measurement unit 

dBm / dB / W / Pass / Fail 

Memory capacity 

99 test 

Auto backlight off time 

30 seconds 

Auto power off time 

10 minutes 

Battery type 

KI6102-xx series: 7.4V 1000mAH rechargeable Lithium battery 
KI6102AA-xx series: 4x AA non-rechargeable battery 

Battery life 

18 hours with rechargeable Lithium battery or 4x AA batteries 

Operating / storage 
temperature 

-10 ~ 60 

  /  -25 ~ 70 

 

Dimensions / Weight   

200 * 90 * 43  mm /   330g 

Содержание KI6102 Series

Страница 1: ...epair of the equipment This Kingfisher International product is guaranteed against defective components and workmanship for a period of 1 year from the date of delivery unless specifically stated in t...

Страница 2: ...ent 4 3 Operation Instructions 6 3 1 ON OFF Instrument 6 3 2 Auto Power Off 6 3 3 Back Light 7 3 4 Selecting Measurement Unit 7 3 5 Relative Measurement Mode 7 3 6 Threshold Setup 7 3 9 Save Retrieve...

Страница 3: ...dB 0 5 Polarization Dependent Loss dB 0 25 Linearity dB 0 1 Through Insertion Loss dB 1 5 Resolution 0 01dB Measurement unit dBm dB W Pass Fail Memory capacity 99 test Auto backlight off time 30 seco...

Страница 4: ...Revision 7 Date 22 Jun 2020 Page 4 of 13 2 The Instrument Figure 1 Front view Rubber holster Optical ports...

Страница 5: ...T Port for 1310nm upstream signal test OLT Port 1490 1550 nm downstream signal test Figure 3 Side View USB connector Connects instrument to a computer Charging Hole Insert connector of the charger to...

Страница 6: ...r Off mode is enabled instrument will turn off automatically if no subsequent key is pressed 10 minutes after it was turned on At Home Display press OFF to disable or enable Auto Power Off mode The in...

Страница 7: ...the displayed measurement unit will change to dB Press F2 to exit Relative Measurement mode 3 6 Threshold Setup 3 6 4 When a wavelength is selected press and hold OK to enter Threshold Editing mode Us...

Страница 8: ...e Display without saving Use to select the next wavelength and set the respective thresholds by repeating steps in 3 6 4 3 6 5 Press OFF to exit Threshold Editing Mode and return to Home Display The T...

Страница 9: ...ss OK to save changes or press OFF to exit Time Setting mode without saving Date format YY MM DD Time format HH MM Time Setting mode will exit automatically if no subsequent key is pressed 10 sec afte...

Страница 10: ...Test Data Browsing mode will exit automatically if no subsequent key is pressed 10 sec after it was selected 3 10 Battery When battery voltage drops below 6 7volt for Lithium battery the indicator wil...

Страница 11: ...d on surface of the sensor this will in turn result in measurement inaccuracy 4 5 Consider leaving test cords connected to the PON meter at all times This will prolong the life of the instrument ONT O...

Страница 12: ...select from the option part number listed below to order suitable AC power adapter plug if needed 6 Safety Take appropriate eye safe precautions when handling live fibre Avoid condensation The instru...

Страница 13: ...Revision 7 Date 22 Jun 2020 Page 13 of 13 Storage During prolonged storage remove batteries to eliminate the possibility of acid leakage Use only high quality batteries...

Отзывы: