KI6680, Mini Fiber Inspection Probe User Manual 

 

Revision 4                                                                                          Date: 31/05/2018                                                                                       Page 10 of 12 

 

 

5.4. To Captured and Save Images on PC 

Click on “Capture” button (see figure above) to capture and save images on PC using default or preferred 

file names as described in the figure.  
Alternatively, press 

Image Capture Button

 on instrument to capture and save images when connected in 

WiFi mode.  This button does not work when instrument is connected in USB mode. 
 
 
 

 
6. Pass / fail Acceptance Guidelines 

Proper guidance on pass/fail criteria is beyond the scope of this manual, since it is likely to vary significantly. 
The Standard ISO/IEC14763-3 Testing of optical fibre cabling specifies requirements and visual standards 
for connector end face inspection with a microscope. 
The standard and common industry practices recommend the following pass/fail acceptance criteria: 

 

 

Markings on the core or damage to the cladding close to the core are unacceptable. 

 

Slight scratches and small pits on cladding, away from the core, are acceptable. 

 

Cracks are not permitted in either core or cladding.  

 
 
 
 

7. Eye Safety Precaution 

While handling live fibers, always observe eye safety procedures compliant with your company policy, 
relevant laser safety standards and safety practices. 
 
 
 
 

8. Care of Your Instrument 

This is a precision optical instrument. Keep it clean, dry and do not drop. Avoid exposure to moisture or 
excessive vibration. When not in use, always 

replace the dust cap to protect the instrument’s adaptor 

or 

adaptor head from accidental damages.   
 
 
 
 

9. Service and Support 

For assistance, please visit our web site 

www.kingfisherfiber.com

 for your local contact details, or for return 

material instructions (RMA). Our application support or service team would be pleased to help.  
 
 
 

Содержание KI 6680

Страница 1: ...vices via WiFi connection only 5 4 1 Download Software 5 4 2 Connect Instrument to Smart Devices 5 4 3 Imaging Software Operation 6 4 4 To Captured and Save Images on Smart Devices 6 5 Viewing Image o...

Страница 2: ...ons including MPO 2 Instrument Overview 2 1 Features Captive dust protective cap Image can be centred and expanded Long operation from built in rechargeable battery with charging via USB C cable On pr...

Страница 3: ...arging instrument Connect instrument to the supplied USB charger or to USB port of PC using the supplied USB cable The Battery Status Indicator comprises of 3 white LEDs show charging status as below...

Страница 4: ...pection adaptor Remove adaptor head on instrument Place MPO inspection adaptor on instrument make sure that pin on adaptor is aligned into the groove on instrument tighten locknut by turning it in the...

Страница 5: ...tunes apple com cn app ki6680 img viewer id1374050279 to download imaging software KI6680 Img Viewer for free For Android devices Scan QR code or go to Google Play https play google com store apps det...

Страница 6: ...ult file names or preferred file names To capture and save images in files with default file names On the Main Display tab on the Image Capturing symbol see picture on next page a small window display...

Страница 7: ...function notes below for image saving Checked A preferred text filename will be appended with a number which auto increment after each image saving operation Unchecked Content of the preferred filenam...

Страница 8: ...Wait until the green LED has lighted up continually Turn on WiFi of your PC connect it to instrument with the network name below Name EasyGet_x x represents the serial number of instrument Password 12...

Страница 9: ...r at adaptor tip Adjust display brightness Type in preferred file name here to save captured image Note If no file name is typed in here images will be saved in the default file names which auto incre...

Страница 10: ...d common industry practices recommend the following pass fail acceptance criteria Markings on the core or damage to the cladding close to the core are unacceptable Slight scratches and small pits on c...

Страница 11: ...ent Ordering Information 11 Ordering Information Description Part Number Instrument Mini Fiber Inspection Probe WiFi USB connection KI 6680 12 Optional Interchangeable Inspection Adaptors Description...

Страница 12: ...iber Inspection Probe User Manual Revision 4 Date 31 05 2018 Page 12 of 12 Scan to download iOS version of imaging software KI6680 Img Viewer Scan to download Android version of imaging software KI668...

Отзывы: