Page 27 of 39
King Pigeon Hi-Tech. Co., Ltd.
Ver 1.0
GSM/SMS/GPRS/3G/4G/Ethernet/Cloud
LoRa Gateway
Features:
LoRa private protocol, simple, secure and reliable;
Working parameters and alarm parameters can be configured through S281 configuration software.
Adopting two working modes, normal working mode and low power consumption mode, automatically
switching according to voltage
In low power consumption mode, an alarm can be triggered within 10 seconds to report the alarm data
directly;
Alarms can be reported directly in normal working mode
Intelligent transmission mechanism, adjust the next transmission time according to its own device number
after a channel collision;
Can send the current value of battery voltage to prevent data loss caused by battery power failure.
Item
Parameter
Temperature Measurement Range
-50~+200℃
,
Accuracy
:±
0.2
℃
Working Mode
Timed wake up to
active reporting(Voltage
≤
6V) Normal working
mode(voltage
≥
6V)
Working Frequency
420MHz~450MHz
(
other frequency can be customized
)
Power Supply
3* AAA
(
3.3V
~
5V
)
Power Consumption
≤
0.24Mw@5V during sleep,
≤
500Mw@5V during working
LoRa Antenna
External SMA 433HMZ antenna
Communication Distance
2km
(
No obstacle
)
Waterproof Level
IP65
Size
101mmX69mmX39mm
Installation
Wall-mounted,flat placed
Packing List
WT106x1,LoRax1,12V power adapter(optional)
3.7.2 Add slave device and set
1.Open the slave device and power on.
WT100
WT104/105/106
2.LED indicator:
D1
:
Configuration mode:After power on,enter pre-configuration mode (keep shinning for 10s),if not
receive configuration data,then enter work mode with previous setting.If set successfully,then it will be off ,then
shiny for1 s,and then off,enter working mode.