Open Com port:

 Click it to open the Comport after choose the correct com port; 

Connect:

              Click it to connect the device to PC after enter the correct password; 

Model Number: 

  This is model number, will update model number automatically when connect 

                                successfully; 

Read Settings:

 Click it to read all of the current configuration parameters from the Data Logger;

 

Save Settings: 

Click it to save all of the PC Configurator parameters to the Data Logger;

 

Load Profile:   

Click it to load additional Profile to the PC Configurator; 

Export Profile: 

Click it to save the present configuration parameters as a profile for next Data     

Logger configuration or backup the parameter settings; 

Tips:

 

The Load Profile and Export Profile is very useful while you need to program bulks of Data Logger with similar 

parameters. After programmed the first unit then you can export profile to save it, for the second Data Logger then 

you can load profile directly to save you time.

 

Default: 

Click it to recovery the parameters to factory defaults; 

Reboot: 

Click it to reboot the data logger; 

Help:

 Click it to the help page; 

RefCom:

 Click it to refresh the com port; 

Device ID:

 (0~65535) non-necessary. This is mainly for monitoring center to identify the data logger, 

if the application no needs to identify the data logger, and then no need to fill in it; 

Device Description:

 This is the description of the data logger, e.g.: installation address, usage 

instructions and so on;(Max: 60 Characters) 

Add Timestamp to Alarm SMS:

 Tick it stands for while alarm occurrence, the Alarm SMS will 

include the data logger’s current time information at the SMS Content. 

Arm automatically when Power On:

 Tick it stands for once the data logger powered up, the data 

logger will enter into Arm Mode automatically. 

Auto Arm after Disarmed:

 Fill the timeout to enter into Armed Mode automatically after disarmed 

operation. This is usefully for security protection applications. 

Tips:

   

Arm:

 

Under this mode, any alarm occurrence will send SMS and dial the authorized numbers immediately. And 

execute the programmed I/O outputs. 

Disarmed

: Under this mode, alarm occurrence will not send SMS & dial the authorized numbers. 

Read Device Time:

 Click it to read the device time. 

Set Device Time:

 Click it to save the time into the device after adjust the time. 

                                (Left-Click to set Hour, right-click to set Minute, Ctrl key restricts to 5 minutes) 

 

Change Password:

 Click it to change a new password. (4 Digits, Arabic numerals only) 

Device Version:

 Click it to read the Model No./Firmware Version/IMEI Code/Signal Value; 

Содержание S264

Страница 1: ...hold alarm with SMS text Message alert Interval Report Onsite temperature humidity to Your Mobile Phone by SMS S264 S265 S266 User Manual Ver 1 2 Date Issued 2017 09 15 King Pigeon Hi Tech Co Ltd www...

Страница 2: ...y is 0 5 C Notice 1 Default version is GSM 2 For 3G WCDMA and 4G LTE version please tell our sales where you would like to use them This handbook has been designed as a guide to the installation and o...

Страница 3: ...mory that can save 200000 events It provides 2 Relay outputs for automatically switch ON OFF devices when Temperature Humidity exceed high low value and remote switch ON OFF Device by SMS or GPRS 3G 4...

Страница 4: ...bile phone directly In built rechargeable battery power lost recover alarm low maintenance 24 7 operation Internal 16MB memory logs more than 200000 records Support Android IOS APP easily friendly for...

Страница 5: ...k flicks quickly registered successful will 2seconds flick once Alarm indicator while alarm occurrence will turn on Relay indicator any one relay close will turn on Armed indicator in Armed mode will...

Страница 6: ...wires Interface Instruction DC in 9 36V DC9 36V positive input 1 5A for power on the Unit DC9 36V negative input 1 5A for power on the Unit Relay Output R1 Relay 1 output R2 Relay 2 output USB USB in...

Страница 7: ...se refer to Chapter 8 Tips 1 Please insert the SIM Card firstly and install the GSM 3G 4G Antenna please power on to check the LEDs status according to above mentioned LED Definitions keep switch on i...

Страница 8: ...In some computer it required download net framework 4 0 while installation then please click Yes to go to Microsoft website to download this service pack Step5 Choose the correct COM port then click...

Страница 9: ...esh the com port Device ID 0 65535 non necessary This is mainly for monitoring center to identify the data logger if the application no needs to identify the data logger and then no need to fill in it...

Страница 10: ...s in this line from Dial Relay ON OFF Dial Tick it stands for enable while alarm Dial to the authorized numbers Timer Report Tick it stands for enable to SMS report to this authorized numbers Arm Disa...

Страница 11: ...arm SMS Content To setup the SMS Content when high alarm Low Alarm SMS Content To setup the SMS Content when low alarm Recovery SMS Content To setup the SMS Content when value back to normal from alar...

Страница 12: ...Hour Minute Stands for what day and at what time does the Data Logger should execute the action Action Stands for what action does the Data Logger should to execute at the specified time E g as above...

Страница 13: ...Point Name GPRS Access Point Name provided by GSM 3G Operator GPRS User Name GPRS User Name provided by GSM 3G Operator GPRS Password GPRS Password provided by GSM 3G Operator Upload Data Interval Tim...

Страница 14: ...ce it full will automatically remove the earlier 100 records for new records The records will including all the values such as time T H value alarm so on Start to testing or work Step1 In order to sav...

Страница 15: ...SMS 8 Once the GSM Unit received the SMS Command will return SMS to confirmation if no SMS return please check your command or resend again 9 The SMS commands that you will certainly use in the GSM un...

Страница 16: ...SMS Content Setup PWD ACxxx Notice xxx stands for delay time range 000 999 minutes 000 stands for alarm immediately 999 stands for DC power lost will not alarm Default is 000 External DC Power Lost D...

Страница 17: ...Notice xx 00 23 stands for hour yy 00 59 stands for minutes Default is 10 00 Daily SMS Report at xx xx Inquiry PWD DRT Daily SMS Report at xx xx Delete PWD DRTDEL 11 Setup Periodically SMS Report Inte...

Страница 18: ...oom Inquiry the Channel Name PWD AIN Series Number nnn AIN1 Temperature Default AIN2 Humidity Default 1234AIN12 to inquiry 1 and 2 Channel name 1234AIN1 to inquiry Channel 1 name Setup Threshold Value...

Страница 19: ...T is fixed Character Series Number Channel Name xxxxx SMS content Max 40 Characters AINTHRx Recovery Default 1234AINTHR1TRecovery Inquiry the Recovery SMS Content PWD AINTHR Series Number Notice The H...

Страница 20: ...PASSWORD SMS Command Return SMS Content Set PWD AP apn username userpassword Notice apn access point name APN User Name Password Inquiry PWD AP Delete PWD APDEL 18 Wakeup GPRS Online SMS Command Retu...

Страница 21: ...please refer to S264 5 6 GPRS 3G 4G Temperature Humidity Data Logger Protocol Instruction 10 Upgrade Firmware The S264 5 6 supports upgrade firmware via USB port directly If we upgraded the firmware f...

Отзывы: