background image

Products

Solutions

Services

Operating Instructions

Ecograph T, RSG35

Universal Data Manager

BA01146R/09/EN/05.16

71344137
Valid as of version

ENU000A, V2.01.xx

Summary of Contents for Ecograph RSG35

Page 1: ...Products Solutions Services Operating Instructions Ecograph T RSG35 Universal Data Manager BA01146R 09 EN 05 16 71344137 Valid as of version ENU000A V2 01 xx ...

Page 2: ......

Page 3: ... output as transmitter power supply for 2 wire sensors 17 6 3 7 Connection example Auxiliary voltage output as transmitter power supply for 4 wire sensors 18 6 3 8 Option RS232 RS485 interface rear of device 18 6 3 9 Ethernet connection rear of device 19 6 3 10 Option Ethernet Modbus TCP slave 20 6 3 11 Option Modbus RTU slave 20 6 3 12 Connections at front of device 20 6 4 Post connection check 2...

Page 4: ...10 3 Historical data Time scaling 47 10 10 4 Historical data Time range displayed 47 10 10 5 Historical data Screenshot 47 10 10 6 Historical data Change the display mode 47 10 11 Signal analysis 48 10 12 Search in trace 48 10 13 Changing the display mode 48 10 14 Adjusting the brightness of the display 48 10 15 Limit values 49 10 16 WebDAV Client 49 10 16 1 Access to the WebDAV server via HTTP HT...

Page 5: ...Ecograph T RSG35 Table of contents Endress Hauser 5 16 1 3 Outputs submenu 119 16 1 4 Communication submenu 120 16 1 5 Application submenu 134 16 1 6 Diagnostics submenu 165 Index 170 ...

Page 6: ...n will result in serious or fatal injury WARNING WARNING This symbol alerts you to a dangerous situation Failure to avoid this situation can result in serious or fatal injury CAUTION CAUTION This symbol alerts you to a dangerous situation Failure to avoid this situation can result in minor or medium injury NOTICE NOTE This symbol contains information on procedures and other facts which do not resu...

Page 7: ...in the event of a problem Visual inspection 1 2 4 Symbols in graphics Symbol Meaning 1 2 3 Item numbers Series of steps A B C Views A A B B C C Sections A0013441 Flow direction A0011187 Hazardous area Indicates a hazardous area A0011188 Safe area non hazardous area Indicates a non hazardous area 1 3 Terminology To improve clarity abbreviations or synonyms are used in these instructions for the fol...

Page 8: ...pplementary documentation as well as in the certificates depending on the application Following instructions and basic conditions The operating personnel must fulfill the following requirements Being instructed and authorized according to the requirements of the task by the facility s owner operator Following the instructions in these Operating Instructions 2 2 Designated use This device is design...

Page 9: ...f the art safety requirements has been tested and left the factory in a condition in which it is safe to operate It meets general safety standards and legal requirements It also complies with the EC directives listed in the device specific EC Declaration of Conformity The manufacturer confirms this by affixing the CE mark to the device 2 6 Safety information for table version option The mains plug...

Page 10: ...mprises Device with terminals as per order 2 fastening clips USB cable Optional Industrial grade SD card card is located in the SD slot behind the flap on the front of the housing Field Data Manager FDM analysis software on DVD Essential Demo or Professional version depending on order FieldCare Device Setup DeviceCare configuration software on DVD Delivery note Multilanguage Brief Operating Instru...

Page 11: ...ge 10 to 50 C 14 to 122 F Climate class as per IEC 60654 1 Class B2 Degree of protection IP65 NEMA 4 at front IP20 housing at rear 5 1 1 Installation dimensions Please observe the installation depth of approx 158 mm 6 22 in for the device incl terminals and fastening clips Panel cutout 138 to 139 mm 5 43 to 5 47 in x 138 to 139 mm 5 43 to 5 47 in Panel strength 2 to 40 mm 0 08 to 1 58 in Angle of ...

Page 12: ...in from walls and other devices 2 Hold the device level and hang the fastening clips in the openings 1 x left 1 x right 3 Evenly tighten the screws on the fasting clip using a screwdriver to guarantee a secure seal to the control panel torque 100 Ncm 5 3 Post mounting check Is the sealing ring undamaged Does the seal run all around the housing collar Are the threaded rods properly tightened Is the...

Page 13: ... breaker Protect the device from overload Provide overload protection nominal current 10 A for power cable Incorrect wiring may result in the device being destroyed Note terminal designation on the rear of the device Energy rich transients in the case of long signal lines Install suitable overvoltage protection e g E H HAW562 upstream 6 2 Connection instructions 6 2 1 Cable specification Cable spe...

Page 14: ...ternal device wiring measures must be taken to allow unrestricted operation when EMC interference is present These measures have been taken into account for this device Operation in the event of disturbance variables as per NAMUR NE21 is thus guaranteed Where applicable national installation regulations and guidelines must be observed during the installation Where there are large differences in po...

Page 15: ...9103 Alarm relay 1 R11 R12 R13 Changeover contact Normally closed contact NC 1 Normally open contact NO 2 Relay 2 to 6 Rx1 Rx2 Switching contact Normally open contact NO 2 1 NC normally closed breaker 2 NO normally open maker 6 3 4 Digital inputs auxiliary voltage output Type Terminal A0019103 Digital input 1 to 6 D11 to D61 GND1 Digital input 1 to 6 Ground for digital inputs 1 to 6 Auxiliary volt...

Page 16: ...3 x4 x5 x6 Current pulse frequency input 1 Voltage 1V Voltage 1V Resistance thermometer RTD 2 wire A B Resistance thermometer RTD 3 wire A b sense B Resistance thermometer RTD 4 wire A a sense b sense B Thermocouples TC 1 If a universal input is used as a frequency or pulse input and the voltage is 2 5 V a series resistor must be used in series connection with the voltage source Example 1 2 kΩ ser...

Page 17: ...rs Frequency Out max 250 mA _ Y _ Y I I 1 2 3 A0020259 4 Connecting auxiliary voltage output when using as a transmitter power supply for 2 wire sensors in the current measuring range When connecting channel CH3 12 see pin assignment CH1 2 1 Sensor 1 e g Cerabar from Endress Hauser 2 Sensor 2 3 External indicator optional e g RIA16 from Endress Hauser ...

Page 18: ...g range When connecting channel CH3 12 see pin assignment CH1 2 1 Sensor 1 e g temperature switch TTR31 from Endress Hauser 2 Sensor 2 3 External indicator optional e g RIA16 from Endress Hauser 6 3 8 Option RS232 RS485 interface rear of device Use shielded signal lines for serial interfaces A combined RS232 RS485 connection is available on a shielded SUB D9 socket at the rear of the device This c...

Page 19: ...should be left empty Maximum cable length RS232 2 m 6 6 ft RS485 1000 m 3280 ft Only one interface can be used at any one time RS232 or RS485 6 3 9 Ethernet connection rear of device The Ethernet interface can be used to integrate the device via a hub or switch into a PC network TCP IP Ethernet A standard patch cable e g CAT5E can be used for the connection Using DHCP the device can be fully integ...

Page 20: ... the Modbus TCP interface is identical to the Ethernet interface 6 3 11 Option Modbus RTU slave The Modbus RTU RS485 interface is galvanically isolated testing voltage 500 V and is used to connect to higher ranking systems to transmit all measured values and process values Up to 12 analog inputs and 6 digital inputs can be transmitted via Modbus and stored in the device Connection is via the combi...

Page 21: ...can be connected if they do not exceed the maximum load of 500 mA If overloaded the corresponding USB devices are automatically disabled Requirements with regard to the USB stick There is no guarantee that all manufacturers USB sticks will function faultlessly That is why an industrial grade SD card is recommended to ensure the reliable recording of data 61 The USB stick must be formatted to FAT o...

Page 22: ...bles or the device damaged Visual inspection Electrical connection Notes Does the supply voltage match the specifications on the nameplate Are all terminals firmly engaged in their correct slot Are the mounted cables strain relieved Are the power supply and signal cables correctly connected See connection diagram and rear of device ...

Page 23: ...nce personnel System Communication Operation Setup Advanced setup Diagnostics Measured Values Operator Maintenance Diagnostics list Outputs Output Event logbook Device information Simulation Change group SD card USB stick History Change date time Date time setup Change display mode Adjust brightness Security External memory Messages Screen saver Device options Inputs Universal inputs Digital input...

Page 24: ...ues Operation Contains all the parameters that are required in ongoing operation configuration of the measured value display displayed values display format etc Maintenance Commissioning Configuration of the measurement Configuration of data processing Setup Contains all parameters for commissioning Change date time Advanced setup submenu Contains additional submenus and parameters System Basic se...

Page 25: ...m Initializes the modem connected to the serial interface for automatic call answering Expert Tasks that require detailed knowledge of the function of the device Commissioning measurements under difficult conditions Optimal adaptation of the measurement to difficult conditions Detailed configuration of the communication interface Error diagnostics in difficult cases Expert Contains all parameters ...

Page 26: ...elect highlighted function parameter change starts ENTER key Access online help Press and hold Navigator 3 sec to show information on the selected function To quit the menu immediately press and hold Back 3 sec in the Navigator The devices switches to display mode 2 LED at SD slot Orange LED lit when the device writes to the SD card or reads it Do not remove the SD card if the LED is lit Risk of d...

Page 27: ...limit value violation and device operation the acquisition of measured values continues uninterrupted 7 4 Display representation of symbols used in operation Item No Function Description 8 12 Symbols for counters å1 Interim analysis external analysis åD Daily analysis åM Monthly analysis åY Annual analysis å Totalizer 8 12 Channel related symbols Violation of lower limit value Violation of upper l...

Page 28: ...xpert setup Back Use the Back function which can be found at the bottom of each menu submenu to move up a level in the menu structure To quit the menu immediately press and hold Back 3 sec in the Navigator The devices switches to display mode 7 4 2 Symbols in the event logbook Setup changes Power on Power off Limit value on Limit value off 1 Digital on on off message 0 Digital off on off message S...

Page 29: ...ss to the operating menu via the local display Using the Navigator jog shuttle dial with additional press function all settings can be made directly onsite at the device 7 8 Device access via operating tools 7 8 1 Field Data Manager FDM analysis software SQL database support The PC analysis software offers external centralized data management with visualization for recorded data The analysis softw...

Page 30: ...ication takes place using automatic device detection the operator does not need to make any additional settings The OPC server enables the flexible and powerful exchange of data and is easy and convenient to use The following momentary values can be provided Analog channels Digital channels Mathematics Totalizer For details see Operating Instructions BA00223R 09 xx 7 8 4 FieldCare DeviceCare confi...

Page 31: ...Data communication with PC software analysis software configuration software OPC server Web server The following connections are possible at the same time 1x Port 8000 configuration software OPC server or analysis software 1x Port 8002 OPC server only 4x Modbus slave TCP 5x Web server Ports can be changed As soon as the maximum number of connections has been reached new connection attempts are blo...

Page 32: ...uring immediately as defined in the settings The values of the channels currently activated are shown on the display Remove the protective film from the display as this would otherwise affect the readability of the display 9 3 Setting the operating language Factory setting English or ordered local language Calling the main menu configuring the operating language 1 Press the navigator 2 The main me...

Page 33: ...vated inputs to a group in the main menu under Setup Advanced setup Application Signal groups Group x 6 Use Back or ESC to quit the main menu The changes made are accepted and saved The device is in the measured value display mode and displays the measured values 9 4 2 Step by step set or delete the limit values Procedure for setting limit values 1 Open the limit values in the main menu under Setu...

Page 34: ... in the appendix at the end of the Operating Instructions 78 9 4 4 Setup via SD card or USB stick An existing device configuration Setup data DEH from another Ecograph T RSG35 or from FieldCare DeviceCare can be uploaded directly to the device Import new setup directly at the device The function used to load the setup data can be found in the main menu under Operation SD card or USB stick Load set...

Page 35: ...e via the Web server Procedure for uploading a new setup via the Web server 1 Make the connection to the device with the Web server 34 2 Click Data management Import device settings in the Web server function bar 3 Select the setup file and press OK to confirm 4 The file is transferred checked and accepted 5 Once the device settings have been accepted information to this effect is displayed in the...

Page 36: ...llel However simultaneous use of the RS232 and RS485 interface is not possible Application Configure various application specific settings e g group settings limit values etc Diagnosis Device information and service functions for a swift device check A detailed overview of all the operating parameters is provided in the appendix at the end of the Operating Instructions 78 9 6 Configuration managem...

Page 37: ...horized access The following options are available Protection per control input Protection via release code Protection via user roles In order to change any parameter the correct code must first be entered or the device must be unlocked using the control input Setup lock via control input The settings for the control input can be found in the main menu under Setup Advanced setup Inputs Digital inp...

Page 38: ...e information Ethernet Display change Ethernet settings The device s Ethernet settings can be found in the main menu under Setup Advanced setup Communication Ethernet Procedure to establish a direct connection via Ethernet point to point connection 1 Configure the PC depends on operating system e g IP address 192 168 1 1 subnet mask 255 255 255 0 gateway 192 168 1 1 2 Disable DHCP on the device 3 ...

Page 39: ...isplayed in alternation with the memory information 12 Display of current measured values and the status in the event of an error alarm condition In the case of counters the type of counter is displayed as a symbol An overview of all the symbols and icons is provided in the operating options section 27 If a measuring point has limit value status the corresponding channel identifier is highlighted ...

Page 40: ...b server in HTML or XML format 10 4 1 Access to the Web server via HTTP HTML When using an Internet browser you just need to enter the address http ip address to have the HTML view displayed in the browser Note Leading zeros in IP addresses must not be entered e g enter 192 168 1 11 instead of 192 168 001 011 As on the display you can alternate between the display groups in the Web server The meas...

Page 41: ...Parameter optional Lower zoom Upper zoom Upper alarm limit Upper warning limit Lower warning limit Lower alarm limit MAN Manufacturer 10 4 3 Remote control via the Web server Remote control of the device is possible via Web server In the Web server remote control can be found under Measured values Remote control Here the display shown corresponds directly to the device display The device is operat...

Page 42: ...V file is created for each group ANSI H4000504428 0000000279 0000000185 2013 11 07 11 30 00 ANALYSIS01 csv Contains the signal analyses of the active channels from the starting time indicated in the file name An individual CSV file is created for every analysis 01 04 ANSI H4000504428 0000000279 2013 11 07 11 18 34 EVENTS csv Contains the event log from the starting time indicated in the file name ...

Page 43: ...g the navigator Only the active groups are displayed here The settings for this can be made in the main menu under Setup Advanced setup Application Signal groups Group x 10 7 Block keyboard navigator Local operation can be blocked in the main menu under Operation Lock operation to prevent unintended or incorrect operation e g when cleaning the device The device is unlocked by pressing the navigato...

Page 44: ...arrier is 100 full The device keeps track of which data have already been copied onto the SD card or USB stick Should you ever forget to change the data carrier in time or if no SD card has been inserted the new external data carrier is filled with the missing data from the internal memory as long as the data are still available there As measured value acquisition recording is assigned the highest...

Page 45: ...ion via port 25 and continues this connection following agreement and switchover to encryption The required process can be selected as follows Setup Advanced setup Application E mail Server requires SSL or under Expert Application E mail Server requires SSL Only TLS V1 0 SSL 3 1 or TLS V1 1 is supported Older standards are not supported The encryption method is automatically agreed with the counte...

Page 46: ...D card or USB stick into the device 3 In the main menu select Operation SD card or USB stick Import SSL certificate 4 Select the required certificate from the list and follow the dialog on the display Up to 3 certificates can be installed simultaneously Verifying the installed SSL certificates The installed certificates can be verified in the main menu under Diagnostics Device information SSL cert...

Page 47: ...pressing the soft key repeatedly 10 10 3 Historical data Time scaling It is possible to scale the displayed time range in the historical data under Operation Time scaling in the data history Notes 1 1 option Every measured value is displayed 1 n option Only every nth measured value is displayed increases the displayed time range No interpolation is performed nor is the mean value determined If the...

Page 48: ...vents The event logbook forms the basis for searches for events To search more easily for certain events e g setup changes the search filter can be used to select and search for the desired events In the standard all events are shown In the event list displayed it is possible to select an event and go directly to this point in the history if still in the memory Search for time When searching for a...

Page 49: ...f the SD card settings memory build up warning and relay The memory is regarded as a stack memory Detailed description of the parameters 164 Note With the WebDAV client the data are transmitted to the WebDAV server in accordance with the selection made in the CSV or protected format 10 16 1 Access to the WebDAV server via HTTP HTML Address entry in browser http ip address webdav The data are updat...

Page 50: ...or alarms General troubleshooting procedure 1 Open diagnosis list lists the 30 most recent diagnostic messages This can be used to determine which errors are currently present and whether an error has repeatedly occurred 2 Diagnosis of current measured values Verify the input signals by displaying the current measured values or the scaled measuring ranges To verify calculations call up calculated ...

Page 51: ...tment F261 Error RAM No access to RAM Contact the Service Department F261 Error Flash No access to flash Contact the Service Department F261 Error SRAM No access to SRAM Contact the Service Department F261 Analog card x out of order Hardware defect detected Contact the Service Department replace card F261 Power supply out of order Hardware defect detected Contact the Service Department replace pow...

Page 52: ...act the Service Department M502 Device is locked Device is locked The message appears when an attempt is made to update the firmware for example Check lock per digital channel F510 Setup was corrected The device detected that the configuration was no longer correct All the parameters affected have been reset to the factory default settings Possible causes Input cards have been removed or replaced ...

Page 53: ...ut not enough free memory space is available Use other SD card USB stick Delete files that are no longer needed from the SD card USB stick M927 Insufficient space free on data storage medium An attempt was made to save the data onto the WebDAV server but there was not sufficient memory available Use other WebDAV server Delete files no longer required from the WebDAV server F929 File is damaged The...

Page 54: ...i e they must be renewed from time to time Install a new certificate M952 SSL certificate expires on The device warns the user shortly before the certificate expires Install a new certificate M953 x certificates have already been installed First of all please delete certificates that are no longer required The device can manage max 3 X 509 certificates Delete a certificate that is already installe...

Page 55: ...d values in the main menu under Diagnostics Measured values The input signals can be verified here by displaying the scaled and calculated values To verify calculations call up calculated auxiliary variables if necessary 11 9 Diagnostics of outputs Displays the current states of the outputs relays 1 6 in the main menu under Diagnostics Outputs 11 10 Simulation Various functions signals can be simu...

Page 56: ...lly answer calls The modem must support the complete AT command syntax Set the baud rate in the main menu under Setup Advanced setup Communication Serial interface and select RS232 as the interface type Connect the modem to the RS232 interface of the device For this purpose only use the modem cable which is available as an accessory A GSM modem can only be initialized if a SIM card is inserted and...

Page 57: ...higher BA01146R 09 05 16 12 Maintenance No special maintenance work is required for the device 12 1 Updating the device software firmware Updating the device software firmware via USB stick SD card or Web server You can access this function in the main menu under Operation SD card or USB stick Update firmware It is advisable to save the setup and measured values beforehand on the SD card or USB st...

Page 58: ...ct can be found online at www endress com spareparts_consumables access to specific device information enter serial number 1 2 3 4 5 6 10 7 8 11 12 13 16 17 18 19 20 14 15 9 A0019863 9 Spare parts diagram Spare parts list Item No Description Order No 1 Casing 71155332 12 Jack screw short 1 piece 71035184 11 Seal housing 71155329 16 Analog card 4 channels XPR0007 A1 4 Display TFT 5 7 VGA flat ribbo...

Page 59: ...PU software XPR0008 _ _ _ _ Operating language Universal XPR0008 A1 Software Standard Mathematics XPR0008 A1A XPR0008 A1B Communication Ethernet RJ45 USB RS232 485 Ethernet RJ45 USB Modbus TCP slave Ethernet RJ45 USB Modbus RTU TCP slave RS232 485 Ethernet RJ45 USB XPR0008 A1_ A XPR0008 A1_ B XPR0008 A1_ C XPR0008 A1_ D Option Standard Neutral XPR0008 A1_ _ A XPR0008 Product structure for option r...

Page 60: ...llow certain procedures when handling products that are in contact with the medium To ensure safe swift and professional device returns please refer to the procedure and conditions for returning devices provided on the Endress Hauser website at http www endress com support return material 13 4 Disposal The device contains electronic components and must therefore be disposed of as electronic waste ...

Page 61: ...Hauser website www endress com 14 1 Device specific accessories Description Order No Industrial Grade SD card industry standard 1GB 71213190 Field Data Manager analysis software with SQL database support 1 x workstation license Professional version MS20 A1 OPC server software full version on CD RXO20 11 Description Order No Accessories for RXU10 data manager RXU10 _ _ Designation Cable set RS232 f...

Page 62: ...top housing cable with Schuko plug Desktop housing cable with US plug Desktop housing cable with Swiss plug 293 4 11 55 236 9 29 173 6 81 188 7 4 184 7 24 207 57 8 17 A0021772 11 Dimensions in mm in RXU10 I _ RXU10 J _ RXU10 K _ Version Standard Neutral RXU10 _ 1 RXU10 _ 2 ...

Page 63: ...e navigator jog shuttle dial via the integrated web server and a PC or via an external keyboard Online help facilitates local operation Reliability Dependability Depending on the device version the MTBF is between 52 years and 24 years calculated based on SN29500 standard at 40 C Serviceability Battery backed time and data memory It is advisable to have the backup battery replaced by a service tec...

Page 64: ...al input U I RTD TC pulse input or frequency input Integration of input variable for totalization e g flow rate m3 h in quantity m3 Calculated values The values of the universal inputs can be used to perform calculations in the mathematics channels Measuring range of analog universal inputs According to IEC 60873 1 An additional display error of 1 digit is permitted for every measured value User d...

Page 65: ...W20Re 0 to 2500 C 32 to 4532 F ASTME 988 96 Type B Pt30Rh Pt6Rh 42 to 1820 C 107 6 to 3308 F IEC 60584 2013 Type C W5Re W26Re 0 to 2315 C 32 to 4199 F ASTME 988 96 Type D W3Re W25Re 0 to 2315 C 32 to 4199 F ASTME 988 96 Type R Pt13Rh Pt 50 to 1768 C 58 to 3214 F IEC 60584 2013 Type S Pt10Rh Pt 50 to 1768 C 58 to 3214 F IEC 60584 2013 0 15 oMR from 500 C 932 F 0 15 oMR from 600 C 1112 F 0 15 oMR fr...

Page 66: ...s 20s 30s 1min 2min 3min 4min 5min 10min 15min 30min 1h Typical recording duration Prerequisites for following tables No limit value violation integration Digital input not used Signal analysis 1 off 2 day 3 month 4 year No active mathematics channels Frequent entries in the event log reduce the memory availability 128 MB internal memory Analog inputs Channels in groups Storage cycle weeks days ho...

Page 67: ...from time Modbus slave Functions of the control input start recording screen saver on lock setup time synchronization limit monitoring on off lock keyboard navigator start stop analysis 15 3 Output Auxiliary voltage output The auxiliary voltage output can be used for loop power supply or to control the digital inputs The auxiliary voltage is short circuit proof and galvanically isolated Output vol...

Page 68: ...digital I O and analog I O max 1 5 mm2 14 AWG spring terminals Wire cross section mains max 2 5 mm2 13 AWG screw terminals Wire cross section relays max 2 5 mm2 13 AWG spring terminals Stripping length 10 mm 0 39 in No ferrules must be used when connecting flexible wires to spring terminals Shielding and grounding Optimum electromagnetic compatibility EMC can only be guaranteed if the system compo...

Page 69: ...ur These can damage the signal cable or significantly impact signal transmission In such cases the shielding of the signal cable is to be grounded on one side only i e it may not be connected to the ground terminal of the housing The shield that is not connected should be insulated 15 4 Power supply Terminal assignment 5 6 9 1 Frequency A0019304 12 Terminals on back of device Supply voltage Extra ...

Page 70: ... existing network without the need for additional configuration The device can be accessed from every PC in the network Normally only the automatic assignment of the IP address must be configured at the client When the device is started it can automatically retrieve the IP address subnet mask and gateway from a DHCP server If a DHCP is not used these settings must be made directly in the device de...

Page 71: ... Relay 350 1 If internal measuring point temperature compensation is used otherwise values as for voltage Reference operating conditions Reference temperature 25 C 77 F 5 K Warm up period 120 min Humidity 20 to 60 rel humidity Hysteresis Can be configured for limit values in the setup Long term drift As per IEC 61298 2 max 0 1 year of measuring range 15 6 Installation Mounting location and install...

Page 72: ...en the devices must be observed if aligning the devices in the Y direction vertically above one another A minimum distance of 10 mm 0 39 in mm inch between the devices must be observed if aligning the devices in the X direction horizontally beside one another Securing to DIN 43 834 Field housing assembly and design optional As an option the device can be ordered ready mounted in a field housing wi...

Page 73: ...vironment NAMUR NE21 Maximum measured error 1 of measuring range Interference emissions as per IEC 61326 1 Class A 15 8 Mechanical construction Design dimensions Information about design and dimensions 71 Weight Panel mounted device with maximum configuration approx 2 2 kg 4 85 lbs Desktop housing excluding device approx 2 3 kg 5 lbs Field housing excluding device approx 4 kg 8 8 lbs Materials Fro...

Page 74: ...elp function and displays operating instructions directly on screen if the navigator jog shuttle dial is pressed for longer than 3 seconds Local operation Display elements Type TFT color display Size diagonal screen measurement 145 mm 5 7 Resolution VGA 307 200 pixels 640 x 480 pixels Backlight 70 000 h half value time half brightness Number of colors 262 000 viewable colors 256 colors used Viewin...

Page 75: ...2 LED at SD slot Orange LED lights up or flashes when the device writes to or reads from the SD card Do not remove the SD card if the LED is lit or flashing Risk of data loss 3 Slot for SD card 4 USB B socket Function e g to connect to PC or laptop 5 Green LED lit power supply present 6 USB A socket Host e g for USB memory stick or external keyboard 7 In display mode alternating status display e g...

Page 76: ...rpose Operating tool Functions Access via Field Data Manager FDM analysis software SQL database support included in the delivery Export of saved data measured values analyses event log Visualization and processing of saved data measured values analyses event log Safe archiving of exported data in a SQL database RS232 RS485 USB Ethernet Web server integrated into the device access via browser Displ...

Page 77: ...is available from the following sources In the Product Configurator on the Endress Hauser website www endress com Click Corporate Select your country Click Products Select the product using the filters and search field Open product page The Configure button to the right of the product image opens the Product Configurator From your Endress Hauser Sales Center www addresses endress com Product Confi...

Page 78: ... the direct access code takes you directly to the desired operating parameter The direct access code is displayed in the Setup menu on the top right of the display e g 00000 000 Text entry e g 00000 000 16 1 1 System submenu Basic settings that are needed to operate the device e g date time etc Language Navigation Expert System Language Direct access code 010000 000 Description Select unit operati...

Page 79: ...ription Select in which form the decimal separator character is to be displayed Options Comma point Factory setting Comma Fault switching Navigation Expert System Fault switching Direct access code 100002 000 Description If the device detects a system error e g hardware defect or a fault e g cable open circuit the selected output switches Options Not used Relay x All the available relays are displ...

Page 80: ...ion Please select the paper size of the printer connected to the PC Options DIN A4 US Letter Factory setting DIN A4 Lock operation Navigation Expert System Lock operation Direct access code 100060 000 Description Local operation is locked in cases of inactivity once the set time has elapsed to prevent inadvertent operation e g when cleaning the device The device is unlocked by pressing the navigat...

Page 81: ...lete internal memory Options No Yes Date time setup submenu Navigation Expert System Date time setup Description Contains settings for date time Date format Navigation Expert System Date time setup Date format Direct access code 110000 000 Description Select in which format the date is to be set and displayed Options DD MM YYYY MM DD YYYY YYYY MM DD Factory setting DD MM YYYY Time format Navigatio...

Page 82: ...one is on UTC universal time coordinated Current date time Navigation Expert System Date time setup Date time Current date time Direct access code 120003 000 Description Displays the current date and the current time Change date time submenu Description Contains parameters for changing the date time Navigation Expert System Date time setup Change date time UTC time zone Navigation Expert System Da...

Page 83: ... 120013 000 Description Set the current date and time for the unit here User entry Date time in set format NT ST changeover submenu Navigation Expert System Date time setup NT ST changeover Description Contains settings for normal time summer time changeover NT ST changeover Navigation Expert System Date time setup NT ST changeover NT ST changeover Direct access code 110002 000 Description Functio...

Page 84: ...tup NT ST changeover Day Direct access code 110006 000 Description Day when in the spring a change from normal to summer time occurs Visible for NT ST changeover Automatic or Manual Only editable if NT ST changeover Manual Options Sunday Monday Tuesday Wednesday Thursday Friday Saturday Factory setting Sunday Month Navigation Expert System Date time setup NT ST changeover Month Direct access code ...

Page 85: ... of time when the time is moved forward by 1 hour on the day of the changeover from normal time to summer time in the set time format Visible for NT ST changeover Automatic or Manual Only editable if NT ST changeover Manual User entry Time in set time format Factory setting 02 00 End summer time Occurrence Navigation Expert System Date time setup NT ST changeover Occurrence Direct access code 1100...

Page 86: ...atic or Manual Only editable if NT ST changeover Manual Options January February March April May June July August September October November December Factory setting October Date Navigation Expert System Date time setup NT ST changeover Date Direct access code 110014 000 Description Date next autumn when summer time changes back to normal time Only visible if NT ST changeover Automatic or Manual C...

Page 87: ...ing No SNTP server 1 Navigation Expert System Date time setup SNTP server SNTP server 1 Direct access code 110021 000 Description Please specify the address of the time server or the IP address Note The DNS server must be configured see Communication Ethernet Your administrator can provide the address where necessary User entry Text field SNTP server 2 Navigation Expert System Date time setup SNTP...

Page 88: ... persons In order to change any parameter the correct code must be entered Factory setting 0 i e changes can be made at any time Hint Make a note of the code and store in a safe place Only visible if Protected by Access code User entry 4 digit number Factory setting 0 Set point code Navigation Expert System Security Set point code Direct access code 100030 000 Description If the unit is protected ...

Page 89: ...s Options Ethernet all ports services USB A socket front USB A socket back USB B socket front Serial interface SD card Factory setting No lock Authentication submenu Navigation Expert System Security Authentication Description Define the passwords for the various user roles to allow device access Visible only if Protected by User roles Operator ID operator Password Navigation Expert System Securit...

Page 90: ...emory submenu Navigation Expert System External memory Description Contains settings for the external data carrier amongst other things which data are to be stored in which format on the external data carrier Save as Navigation Expert System External memory Save as Direct access code 140000 000 Description Protected format All data are stored in a manipulation protected encrypted format They can b...

Page 91: ...IFO Ring memory can be selected only if Save as is set to protected format and not CSV Factory setting Stack memory Warning at Navigation Expert System External memory Warning at Direct access code 140005 000 Description Issues a warning before the data carrier is x full A warning is indicated on the device and this is also stored in the event buffer A relay can also be switched Only for external ...

Page 92: ...em External memory Date time Direct access code 140003 000 Description Please select if the date and time should be stored in one column or separate columns when data are saved in CSV format files Options One column Separate columns Factory setting Separate columns Operating time Navigation Expert System External memory Operating time Direct access code 140004 000 Description Please select in whic...

Page 93: ...iption A relay can be switched as soon as a message that has to be confirmed is displayed e g on off message device errors etc The relay assumes the initial status as soon as all messages have been confirmed Options Not used Relay x All the available relays are displayed Factory setting Not used Screen saver submenu Navigation Expert System Screensaver Description To increase the life span of the ...

Page 94: ...y from Navigation Expert System Screen saver OFF daily from Direct access code 160002 000 Description Set time hh mm as of when the screensaver should be switched off e g shift start time Only visible if screen saver switched daily User entry Time hh mm Factory setting 07 00 Alarm response Navigation Expert System Screen saver Alarm response Direct access code 160003 000 Description Off on alarm I...

Page 95: ...n order to enable the new option The activation code entered is not displayed i e this parameter is always empty following a restart Pay attention to case sensitivity User entry Text Slot 1 Navigation Expert System Device options Slot 1 Direct access code 990000 000 Description Shows hardware or software options Cannot be edited The assignment can be specified in the PC operating software for offl...

Page 96: ...ts Communication Navigation Expert System Device options Communication Direct access code 990006 000 Description Shows hardware or software options Cannot be edited Options USB Ethernet USB Ethernet RS232 485 Fieldbus Navigation Expert System Device options Fieldbus Direct access code 990005 000 Description Shows hardware or software options Cannot be edited Options Not available Modbus Slave Appl...

Page 97: ...000 Description Addition of an input that must be switched on and configured according to the input signal Options No universal input x Factory setting No Delete input Navigation Expert System Inputs Universal inputs Delete input Direct access code 222001 000 Description Delete an input configuration Options No universal input x Factory setting No Universal input x submenu Navigation Expert System...

Page 98: ...on the rear of the unit Only visible if signal switched off Options Switched off Current 4 20 mA 0 20 mA 0 5 mA 0 20 mA squared 4 20 mA squared 20 mA Voltage 0 1 V 0 10 V 0 5 V 1 5 V 150 mV 1 V 10 V 30 V 0 1 V squared 0 10 V squared 1 5 V squared Resistance thermometer Pt100 IEC Pt100 JIS Pt100 GOST Pt500 IEC Pt500 JIS Pt1000 IEC Pt1000 JIS Pt46 GOST Pt50 GOST Cu50 GOST a 4260 Cu50 GOST a 4280 Cu5...

Page 99: ...11 Description The analog inputs are scanned in a 100ms cycle Depending on the memory cycle the selected data are determined saved and displayed based on the scanned values Options Instantaneous value Average Minimum value Maximum value Minimum Maximum Counter Current value Counter Factory setting Average Time base Navigation Expert Inputs Universal inputs Universal input x Time base Direct access...

Page 100: ...echnical units of the count input e g gal cf Only visible if signal Pulse counter and plot type Current value counter User entry Text max 6 characters Pulse counter Navigation Expert Inputs Universal inputs Universal input x Pulse counter Direct access code 220017 0xx Examples Universal input 1 220017 000 Universal input 12 220017 011 Description Please check if the pulse counter used is a fast or...

Page 101: ...nt for the display Only visible if signal switched off Options None One X Y Two X YY Three X YYY Four X YYYY Five X YYYYY Factory setting One X Y Lower frequency Navigation Expert Inputs Universal inputs Universal input x Lower frequency Direct access code 220018 0xx Examples Universal input 1 220018 000 Universal input 12 220018 011 Description Configure the lower frequency that corresponds to th...

Page 102: ...versal input 12 220019 011 Description Configure the upper frequency that corresponds to the end of the measuring range Only visible if signal frequency input User entry 0 to 12500 Hz Factory setting 1000 0 Hz Meas range end Navigation Expert Inputs Universal inputs Universal input x Meas range end Direct access code 220007 0xx Examples Universal input 1 220007 000 Universal input 12 220007 011 De...

Page 103: ...mples Universal input 1 220012 000 Universal input 12 220012 011 Description Like Zoom start However enter the upper value of the required range here The zoom can also be set outside the measuring range The only restriction is that the start and end of the zoom may not be identical If the signal or the range is changed the zoom is corrected if it no longer fits the measuring range The zoom end can...

Page 104: ...sal input x Comparison temp Direct access code 220014 0xx Examples Universal input 1 220014 000 Universal input 12 220014 011 Description Settings for the external comparison temperature only when connecting thermocouples Only visible if comparison point external User entry 0 to 9999999 Depends on the temperature unit selected Factory setting 0 Depends on the temperature unit selected Totalizer Na...

Page 105: ...050 0xx Examples Universal input 1 220050 000 Universal input 12 220050 011 Description This offset is only effective on the analog input signal no maths bus channels Only visible if signal resistance thermometer or thermocouple User entry Number max 8 digits Factory setting 0 Correction RPT Navigation Expert Inputs Universal inputs Universal input x Meas val corrct Correction RPT Direct access co...

Page 106: ...e Direct access code 220053 0xx Examples Universal input 1 220053 000 Universal input 12 220053 011 Description Enter the lower value actually measured here e g measuring range 0 C to 100 C measured value 0 5 C Only visible if signal current or voltage User entry Number max 8 digits Factory setting 0 Meas range end Target value Navigation Expert Inputs Universal inputs Universal input x Meas val c...

Page 107: ...talization of flow or power consumption Totalization Navigation Expert Inputs Universal inputs Universal input x Totalization Totalization Direct access code 220030 0xx Examples Universal input 1 220030 000 Universal input 12 220030 011 Description By totalizing the analog signal e g flow rate in m h quantities in m can be calculated Options No Yes Factory setting No Totalization base Navigation E...

Page 108: ... value these quantities are not added to the counter If the input is scaled from 0 to y or if the pulse input is used all values that are smaller than the set value are not recorded If the input is scaled from x to y all values around the zero point e g also negative values are not recorded Only visible if totalization yes User entry Number max 8 digits Factory setting 0 Calc factor Navigation Exp...

Page 109: ...tion Expert Inputs Universal inputs Universal input x Fault mode Description Contains settings that define how this channel is to react under fault conditions e g cable open circuit over range NAMUR NE 43 Navigation Expert Inputs Universal inputs Universal input x Fault mode NAMUR NE 43 Direct access code 220060 0xx Examples Universal input 1 220060 000 Universal input 12 220060 011 Description Ac...

Page 110: ...0065 000 Universal input 12 220065 011 Description When NE43 is switched off defines the value that must be undershot for the device to output an error Only visible if signal Current range 4 20 mA and NAMUR NE 43 Off User entry Number max 8 digits 0 to 4 mA Factory setting 3 9mA Upper error value Navigation Expert Inputs Universal inputs Universal input x Fault mode Upper error value Direct access...

Page 111: ...ice should continue working with for calculations if the measured value is not valid e g cable open circuit In the event of an error value all the dependent calculations are flagged accordingly as error value Counters are not flagged however Options Invalid calculation Error value Factory setting Invalid calculation Error value Navigation Expert Inputs Universal inputs Universal input x Fault mode...

Page 112: ... from all the available universal inputs Factory setting Switched off Submenu Digital inputs Digital input x Navigation Expert Inputs Digital inputs Digital input x Description Setting up only required if the digital inputs e g events are to be used x place holder for selected digital input Add input Navigation Expert System Digital inputs Add input Direct access code 252000 000 Description Additi...

Page 113: ...Function Navigation Expert Inputs Digital inputs Digital input x Function Direct access code 250014 00x Examples Digital input 1 250014 000 Digital input 6 250014 005 Description Specifies how the data from the fieldbus is interpreted processed Only visible if function Modbus Slave Options Switched off Control input On off event Pulse counter Operational time Event operation time Quantity from tim...

Page 114: ...imal point Direct access code 250004 00x Examples Digital input 1 250004 000 Digital input 6 250004 005 Description Number of places after decimal point for the display Only visible if function pulse counter or quantity from time Options None One X Y Two X YY Three X YYY Four X YYYY Five X YYYYY Factory setting One X Y Input factor in Navigation Expert Inputs Digital inputs Digital input x Input f...

Page 115: ...ode 250005 00x Examples Digital input 1 250005 000 Digital input 6 250005 005 Description Factor that when multiplied by the operating time results in the required physical value Examples 1 second equals 8 l enter 8 Only visible if function quantity from time User entry Number max 8 digits Factory setting 1 Time delay Navigation Expert Inputs Digital inputs Digital input x Time delay Direct access...

Page 116: ...gnal is present Otherwise all key activation and navigator actions are discarded Start stop analysis 1 Starts ends the external analysis the analysis only runs as long as the signal is high Measured value acquisition for the graphic display continues Options Switched off Start stop recording Screensaver on Block set up Time synchronization Set point monitoring on off Block keyboard navigator Start...

Page 117: ...hown in the display and saved to memory Only visible if function control input on off event event operation time User entry Text max 6 characters Factory setting Off Save event Navigation Expert Inputs Digital inputs Digital input x Save event Direct access code 250009 00x Examples Digital input 1 250009 000 Digital input 6 250009 005 Description Determines whether the condition change from low to...

Page 118: ...ent text is set the device generates an automatic event text factory setting e g digital 1 L H Only visible if function control input on off event event operation time User entry Text max 22 characters Event text H L Navigation Expert Inputs Digital inputs Digital input x Event text H L Direct access code 250011 00x Examples Digital input 1 250011 000 Digital input 6 250011 005 Description Descrip...

Page 119: ...al input 6 250013 005 Description Initial setting for the totalizer Useful when continuing measurements recorded to date with an electro mechanical counter Only visible if function pulse counter operational time event operation time or quantity from time User entry Number max 15 digits Factory setting 0 Copy settings Navigation Expert Inputs Digital inputs Digital input x Copy settings Direct acce...

Page 120: ...g Identifier Navigation Expert Outputs Relay x Identifier Direct access code 330001 00x Examples Relay 1 330001 000 Relay 6 330001 005 Description Presettable relay identifier User entry Text max 16 characters Factory setting Relay x 16 1 4 Communication submenu Set up required if you are using the USB RS232 RS485 or Ethernet interface of the unit PC operation serial data read out modem operation ...

Page 121: ...ieldbus Navigation Expert Communication Timeout fieldbus Direct access code 150210 000 Description Time within which measured values must be received via fieldbus otherwise an error will be set Not relevant if only measured values are read out User entry 1 to 99s Factory setting 10 s Ethernet submenu Navigation Expert Communication Ethernet Description Contains the set up required if you are using...

Page 122: ...mmunication Ethernet IP address Direct access code 150003 000 Description Please enter the IP address given from your network administrator Please talk to your network administrator about this Only editable if DHCP no User entry IP address Factory setting 000 000 000 000 Subnet mask Navigation Expert Communication Ethernet Subnet mask Direct access code 150004 000 Description Please enter the subn...

Page 123: ...on Expert Communication Ethernet Disable port Direct access code 150020 000 Description You can disable unused ports for security reasons CDI is the protocol that the configuration software or reporting software uses to communicate with the device All other ports e g SNTP SMTP Web server are automatically disabled if the function is switched off Options CDI OPC Modbus Slave Factory setting no port...

Page 124: ... Switch the Web server functionality on off The instantaneous values can only be displayed using an Internet browser when the web browser is activated A connection to the Web server can only be established via the Ethernet interface Options No Web server is off Yes Web server is active Factory setting Yes Configuration Web server submenu Navigation Expert Communication Ethernet Configuration Web s...

Page 125: ...rver For security reasons it is advisable to switch off configuration via the Web server after commissioning With regard to IT security please contact your network administrator if necessary Options No Yes Factory setting Yes Firmware update Navigation Expert Communication Ethernet Configuration Web server Firmware update Direct access code 470002 000 Description Firmware can be updated via Web se...

Page 126: ...ous users with which the device can be accessed via Web server Operator Admin Service Measured value display Yes Yes Yes Display instrument health status Yes Yes Yes Configuration No Yes Yes Configuration incl service parameter No No Yes Update firmware No Yes Yes WebDAV Yes Yes Yes Note The following passwords should be changed during commissioning Operator ID Navigation Expert Communication Ethe...

Page 127: ...rator ID Navigation Expert Communication Ethernet Configuration Web server Authentication ID Direct access code 470101 000 Description ID required in order to access the device Pay attention to case sensitivity Cannot be edited Factory setting admin Password Navigation Expert Communication Ethernet Configuration Web server Authentication Password Direct access code 470102 000 Description Enter a p...

Page 128: ...tting service Timeouts submenu Navigation Expert Communication Ethernet Configuration Web server Timeouts Description Timeouts for the Web server Settings should only be modified if slow network connections are causing transmission problems The settings are only adopted if the browser has been restarted or a new tab opened Caution Settings should only be changed by experts Connection quality Navig...

Page 129: ...igation Expert Communication Ethernet Configuration Web server Timeouts Set timeout Direct access code 470202 000 Description Maximum time to write a value or execute an action before the browser ends the connection User entry 5 to 999 s Factory setting 5 Put timeout Navigation Expert Communication Ethernet Configuration Web server Timeouts Put timeout Direct access code 470203 000 Description Max...

Page 130: ...ration Web server Timeouts Ping timeout Direct access code 470205 000 Description Time in which the device must respond before the browser ends the connection User entry 5 to 999 s Factory setting 15 Ping retry Navigation Expert Communication Ethernet Configuration Web server Timeouts Ping retry Direct access code 470206 000 Description Number of retries if the device does not respond User entry 0...

Page 131: ...ions RS232 RS485 Debug only for service purposes Factory setting RS232 Protocol Navigation Expert Communication Serial interface Protocol Direct access code 150105 000 Description Define the serial interface protocol Note The device automatically disables incompatible settings Options PC software Modbus Slave only if type RS485 Factory setting PC software Baud rate Navigation Expert Communication ...

Page 132: ...op bits Only visible if protocol PC software Options 1 2 Factory setting 1 Unit address Navigation Expert Communication Serial interface Unit address Direct access code 150102 000 Description Every unit operating using RS232 RS485 must have an individual address 00 30 Only visible if type RS485 User entry 0 to 30 Factory setting 0 Modbus Slave submenu option Navigation Expert Communication Modbus ...

Page 133: ...Enter the device address where it should be possible to reach this device in the bus Only visible if Modbus RS485 User entry 1 to 247 Factory setting 1 Port Navigation Expert Communication Modbus Slave Port Direct access code 480004 000 Description Port via which the Modbus protocol can be activated Only visible if Modbus Ethernet User entry Number max 5 digits Factory setting 502 Serial interface...

Page 134: ... Direct access code 150103 000 Description Parity Only visible if Modbus RS485 Options None Even Odd Factory setting None Stop bits Navigation Expert Communication Modbus Slave Serial interface Stop bits Direct access code 150104 000 Description Parity Only visible if Modbus RS485 and parity none Options 1 2 Factory setting 1 16 1 5 Application submenu Configure various application specific settin...

Page 135: ...cription Measurement point name e g Pump or description of the function of this input e g Fault message User entry Text max 16 characters Factory setting Maths x Formula Navigation Expert Application Maths Maths x Formula Direct access code 400002 000 Examples Maths 1 400002 000 Maths 4 400002 003 Description Enter the desired calculation formula Analog digital or already active mathematics channe...

Page 136: ...s that are configured as operational time are added together the result is the total of all the individual operating times Control input The function corresponds to a digital input that has been configured as a control input Options Instantaneous value State Counter Operating time from status Operating time from total Control input Factory setting Instantaneous value Plot type Navigation Expert Ap...

Page 137: ...Screensaver on Switches backlight display off low off high on Lock setup The user can only change the setup if a low signal is present Time synchronization If a high signal is applied the device rounds the system time up or down only for low high change to the nearest minute 0 to 29 Round down 30 to 59 round up Set point monitoring on off The entire set point monitoring function of the device can ...

Page 138: ...scription Condition description when the digital input is active This text is both shown in the display and saved to memory Only visible if the result is control input or state User entry Text max 6 characters Factory setting On Description L Navigation Expert Application Maths Maths x Description L Direct access code 400009 00x Examples Maths 1 400009 000 Maths 4 400009 003 Description Condition ...

Page 139: ...edged by operating a push button Only visible if the result is control input or state Options Do not acknowledge Acknowledge Factory setting Do not acknowledge Event text L H Navigation Expert Application Maths Maths x Event text L H Direct access code 400011 00x Examples Maths 1 400011 000 Maths 4 400011 003 Description Description of condition change from low to high Event text is stored e g Sta...

Page 140: ...or state Options No Yes Factory setting No Zoom start Navigation Expert Application Maths Maths x Zoom start Direct access code 400016 00x Examples Maths 1 400016 000 Maths 4 400016 003 Description If the whole value range is not used you can configure the lower value of the required section here Zooming does not affect the save function Only visible if the result is instantaneous value User entry...

Page 141: ...ith the formula currently used appears If the field is empty a formula has not yet been defined for the mathematics channel Description Individual channels can be mathematically linked and calculated with functions The mathematics channels calculated in this way are treated as real channels regardless of whether they are connected conventionally or via fieldbus Enter the desired calculation formul...

Page 142: ...ation Not all signal types are available for each input type These depend on the respective device options Channel number Analog channel 1 1 analog channel 2 2 digital channel 1 1 Examples DI 2 4 State of digital channel 4 AI 1 1 Instantaneous value of analog channel 1 Status of a limit value LMT type limit number Type Description 1 Instantaneous value Currently set limit value 2 State The functio...

Page 143: ...Syntax errors e g wrong number of parameters occur in the formulas There are incorrect parentheses in the formula number of open parentheses unequal to number of closed parentheses Division is by zero A channel refers to itself infinite recursion Invalid formulas are deactivated when the setup is accepted or the device is started Undetectable errors wherever possible errors in the formula are repo...

Page 144: ... 1 400052 000 Maths 4 400052 003 Description Enter the unit for the calculated quantity e g m Only visible if totalization yes User entry Text max 6 characters Low flow cut off Navigation Expert Application Maths Maths x Totalization Low flow cut off Direct access code 400053 00x Examples Maths 1 400053 000 Maths 4 400053 003 Description If the volume flow recorded is below the set value these qua...

Page 145: ...03 Description Initial setting for the totalizer Useful when continuing measurements recorded to date with an electro mechanical counter Only visible if totalization yes User entry Number max 15 digits Factory setting 0 Fault mode submenu Navigation Expert Application Maths Maths x Fault mode Description Contains settings that specify how this channel is to behave in the event of an error e g if a...

Page 146: ...ing 0 Copy settings Navigation Expert Application Maths Maths x Copy settings Direct access code 400200 00x Examples Maths 1 400200 000 Maths 4 400200 003 Description Copies settings from actual channel to selected channel Options No In maths channel x Users can choose from all the available maths channels Factory setting No Signal analysis submenu Navigation Expert Application Signal analysis Des...

Page 147: ...ion Expert Application Signal analysis Synchron time Direct access code 440004 000 Description Time for completing the signal analysis If for example 07 00 is set up then the daily analysis will run from 07 00 on the current day until 07 00 on the following day User entry Time Factory setting 00 00 Reset to zero Navigation Expert Application Signal analysis Reset to zero Direct access code 440007 ...

Page 148: ...is violated Add limit value Navigation Expert Application Limits Add limit value Direct access code 450300 000 Description Adding a new limit value Options No Yes Factory setting No Delete limit value Navigation Expert Application Limits Delete limit value Direct access code 450301 000 Description Deleting a limit value from the list Options No limit value x Factory setting No Set point x submenu ...

Page 149: ...e of limit value depends on the input variable Options Switched off Upper set point Lower set point Analysis x Description of the individual set point types Set point type function Description Hysteresis For every set point the switch point can be controlled via a hysteresis The hysteresis is set as an absolute value positive values only in the unit of the respective channel e g upper set point 10...

Page 150: ...hen a limit value is exceeded and measures the time from which the value is exceeded If the measured value falls below the limit value the delay is reset This also occurs if the measured value falls below the limit value but continues to be higher than the set hysteresis value When the limit value is exceeded again the time delay once more becomes active and starts measuring from 0 t Measured valu...

Page 151: ...004 029 Description The alarm condition is only canceled when the signal has changed into the normal operation range by the preset value User entry Number max 8 digits Factory setting 0 Time delay Navigation Expert Application Limits Limit x Time delay Direct access code 450005 0xx Examples Set point 1 450005 000 Set point 30 450005 029 Description In order to be interpreted as an alarm the signal...

Page 152: ...edge Acknowledge Factory setting Do not acknowledge Save event Navigation Expert Application Limits Limit x Save event Direct access code 450008 0xx Examples Set point 1 450008 000 Set point 30 450008 029 Description Stores a message in the event log on limit value violation Options No Yes Factory setting Yes Event text LV on Navigation Expert Application Limits Limit x Event text LV on Direct acc...

Page 153: ...he duration is appended to the limit value off event text format hhhh h mm ss Power failure times do not affect the duration If the set point was violated before the power failure and is still violated after the power failure the duration continues Options No Yes Factory setting No Save cycle Navigation Expert Application Limits Limit x Save cycle Direct access code 450012 0xx Examples Set point 1...

Page 154: ...0200 029 Description Copies settings from actual channel to selected channel Options No in limit x all the limits are displayed Factory setting No Signal groups submenu Navigation Expert Application Signal groups Description Group the analog digital and or mathematics channels such that you can call up important information at the press of a button during operation e g temperatures signals in plan...

Page 155: ...n 5min 10min 15min 30min 1h Factory setting 1min Alarm cycle Navigation Expert Application Signal groups Group x Alarm cycle Direct access code 460002 0xx Examples Group 1 460002 000 Group 4 460002 003 Description Configure the save cycle with which this group should be saved in an alarm condition set point violation Attention Requires higher memory capacity Options Off 1s 2s 3s 4s 5s 10s 15s 20s ...

Page 156: ...ory setting Instantaneous value state Display black Navigation Expert Application Signal groups Group x Display black Direct access code 460005 00x Examples Group 1 460005 000 Group 4 460005 003 Description Choose which input calculate variable should be displayed in this group Options Switched off Universal input x Digital input x Maths x Factory setting Switched off Display Navigation Expert App...

Page 157: ...splayed Options Instantaneous value state Analysis x Totalizer Everything Factory setting Instantaneous value state Display green Navigation Expert Application Signal groups Group x Display green Direct access code 460009 00x Examples Group 1 460009 000 Group 4 460009 003 Description Choose which input calculate variable should be displayed in this group Options Switched off Universal input x Digi...

Page 158: ...lease select which data from the selected channel should be displayed Options Instantaneous value state Analysis x Totalizer Everything Factory setting Instantaneous value state Display orange Navigation Expert Application Signal groups Group x Display orange Direct access code 460013 00x Examples Group 1 460013 000 Group 4 460013 003 Description Choose which input calculate variable should be dis...

Page 159: ... off Display Navigation Expert Application Signal groups Group x Display Direct access code 460016 0xx Examples Group 1 460016 000 Group 4 460016 003 Description Please select which data from the selected channel should be displayed Options Instantaneous value state Analysis x Totalizer Everything Factory setting Instantaneous value state Display brown Navigation Expert Application Signal groups G...

Page 160: ...play 0 to 14pH select 14 divisions Options 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Factory setting 10 Zoom Navigation Expert Application Signal groups Group x Zoom Direct access code 460028 0xx Examples Group 1 460028 000 Group 4 460028 003 Description Defines the zoom that is shown in Curves or Waterfall display mode This setting does not affect other display modes e g Curves in range ...

Page 161: ...er the e mail server requires a secure connection SSL STARTTLS Runs on the same TCP port as unencrypted SMTP port 25 or 587 SMTPS Completely encrypted with own TCP port 465 If necessary contact your network administrator or e mail provider Options No Yes SMTPS Yes STARTTLS Factory setting No Port Navigation Expert Application E mail Port Direct access code 510063 000 Description Enter your SMTP po...

Page 162: ... necessary contact your network administrator or e mail provider User entry Text max 60 characters Password Navigation Expert Application E Mail Password Direct access code 510067 000 Description Enter the password for authentication here If necessary contact your network administrator or e mail provider User entry Text max 22 characters E mail addresses submenu Navigation Expert Application E mai...

Page 163: ...cation E mail Limit value violations Recipient x Direct access code Recipient 1 510110 000 Recipient 2 510111 000 Description Select who should receive the e mail Options Not used E mail address x Factory setting Not used On off messages submenu Navigation Expert Application E mail On off messages Description Specify who should receive e mails when on off messages occur for digital inputs or maths...

Page 164: ...t who should receive the e mail Options Not used E mail address x Factory setting Not used Maintenance required submenu Navigation Expert Application E mail Maintenance required Description Specify who should receive e mails when maintenance is required Mxxx messages Recipient x Navigation Expert Application E mail Maintenance required Recipient x Direct access code Recipient 1 510130 000 Recipien...

Page 165: ...r name Input of the user name that can access the WebDAV server Entry Text max 20 characters 472004 000 Password Password for accessing the WebDAV server Entry Text max 20 characters 472007 000 Directory Enter the directory in which the data should be saved Entry Text max 120 characters 472005 000 Save as Protected format All data are stored in a manipulation protected encrypted format They can be...

Page 166: ...vigation Expert Diagnostics Diagnosis list Description All diagnosis messages are listed in chronological order Event logbook submenu Navigation Expert Diagnostics Event logbook Description Events such as alarm set point infringement and power failure are listed in the correct time sequence Device information submenu Navigation Expert Diagnostics Device information Description Displays important d...

Page 167: ...identifies the device It can also be found on the nameplate Uses of the order code To order an identical spare device To check the ordered device features using the delivery note Firmware Version Navigation Expert Diagnostics Device information Firmware Version Direct access code 000026 000 Description Displays the installed firmware version of the device Please send these details with any questio...

Page 168: ...access code 000022 000 Description Displays the manufacturer ID Please send these details with any questions about the unit Manufacturer name Navigation Expert Diagnostics Device information Manufacturer name Direct access code 000023 000 Description Displays the manufacturer name Please send these details with any questions about the unit Firmware Navigation Expert Diagnostics Device information ...

Page 169: ... mode Direct access code 010010 000 Description Normal operation Unit plots the signals from the connected measurement points Simulation Instead of operating with the real measurement points the signals are simulated using the actual settings Options Normal operation Simulation Factory setting Normal operation ...

Page 170: ...r 92 Current date time parameter 82 D Damping parameter 103 Date parameter 85 86 Date format parameter 81 Date time parameter 83 92 Date time submenu 82 Date time setup submenu 81 Day parameter 84 85 Decimal point parameter 101 114 Decimal separator parameter 79 Declaration of Conformity 9 Delete input parameter 97 112 Delete limit value parameter 148 Description H parameter 116 138 Description L ...

Page 171: ...eter 135 Maths x decimal point parameter 137 Maths x engineering unit parameter 136 Maths x function parameter 135 Maths x plot type parameter 136 Measured value correction submenu 105 Memory build up parameter 91 Messages submenu 92 Modbus parameter 133 Modbus RTU TCP IP 31 Modbus Slave submenu 132 Modbus Slave baud rate parameter 133 Modbus Slave parity parameter 134 Modbus Slave serial interfac...

Page 172: ...P server 2 parameter 87 Staff Requirements 8 Stop bits parameter 132 Structure of the operating menu 23 24 Subnet mask parameter 122 Swap mouse buttons parameter 80 Switches parameter 121 151 Switches relay parameter 91 93 116 137 Symbols Event logbook 28 Operating menus 28 Synchron time parameter 147 System submenu 78 T Target value parameter 105 106 Temperature unit parameter 79 Text entry 28 Th...

Page 173: ......

Page 174: ...www addresses endress com ...

Reviews: