![background image](http://html1.mh-extra.com/html/king-pigeon/s264/s264_user-manual_1969930019.webp)
Page 19 of 21 King Pigeon Hi-Tech. Co., Ltd. Ver 1.0
GSM/SMS/GPRS/3G/4G
Temperature&Humidity Data Logger
Inquiry the
High Alarm
SMS Content
PWD+AINH+Series
Number (
Notice:
H and T is
fixCharacter,Series
Number=Channel Name
)
AINHx: High Alarm (Default)
1234AINH12
This command can inquiry the
SMS content both channel 1
and channel 2
Setup the Low
Alarm SMS
Content
PWD+AINL+Series
T+xxxxxx
(
Notice:
The H and T is fixed
Character,
Series
Number=Channel
Name,
xxxxx=SMS content, Max:40
Characters
)
AINLx: Low Alarm (Default)
1234AINL1TLow Alarm
Inquiry the Low
Alarm SMS
Content
PWD+AINL+Series
Number
(
Notice:
The H and T is
fixed
Character,
Series
Number=Channel Name
)
AINLx: Low Alarm (Default)
1234AINL12
This command can inquiry the
SMS content both channel 1
and channel 2
Setup the
Recovery SMS
Content
PWD+Series
T+xxxxxx
(
Notice:
The H and T is fixed
Character,
Series
Number=Channel
Name,
xxxxx=SMS content, Max:40
Characters
)
AINTHRx: Recovery (Default)
1234AINTHR1TRecovery
Inquiry the
Recovery SMS
Content
PWD+Series
Number
(
Notice:
The H and T is fixed
Character,
Series
Number=Channel Name
)
AINTHRx: Recovery (Default)
1234AINL12
This command can inquiry the
SMS content both channel 1
and channel 2
Setup the
Temperature &
Humidity Alarm
Verify Time
PWD+AIN+Series
Qyyy
(
Notice:
The AIN and Q is
fixed
Character,
Series
Number=Channel
Name,yyy=verify
time,
3
digits,
default=002,
999=Not alarm
)
TEMP: yyy Seconds
Humidity: yyy Seconds
1234AIN1Q002
This command set the alarm
verify time is 2
seconds.(Default)
Inquiry the
Temperature &
Humidity Alarm
Verify Time
PWD+AINQ
TEMP: yyy Seconds
Humidity: yyy Seconds
1234AINQ
This command stands for
inquiry all the channnels
14)
Setup save historical data periodically time
SMS Command
Return SMS Content
Set
PWD+HISSAVExxxxxxx
(
Notice:
xxxxxxx=0~65535 seconds, default is 0, stands
for not save.
)
save historical data
periodically time
is:xxxxxSeconds