11. Functions recap
Code
Description
Available settings
200
400
Unit of channel 1
dbu
o
s
M
xxx
00
Pa
01
mmH O
2
02
inWg
03
mbar
Code
Description
Available settings
300
0
=>0V,
1
=>5V,
2
=>10V
3
=>4mA,
4
=>12mA,
5
=>20mA
600
602
604
612
614
616
618
Analogue output setting on channel 1
301
Analogue output minimum on channel 1
302
Analogue output maximum on channel 1
306
Activation / Deactivation of purge mode
00 or 01
307
Working time of each purge
from 01 to 60 seconds
308
Frequency of each purge
from 01 to 9999 minutes
309
Time-delay after purge
from 00 to 60 seconds
dbu
o
s
M
xxx
Code
Description
Available settings
500
0 to 9
1000
1002
Measurement integration
from
501
Self-calibration for time-delay
from 0 to 60 minutes
dbu
o
s
M
xxx
Page 25
Code
Description
101
102
103
Available settings
100
Channel n° for IR remote control
0 to 9
Sending data via Rs232
0 or 1
Serial number display
Modbus slave number
1 to 32
104
Modbus communication speed
200
202
204
206
208
dbu
o
s
M
xxx
00
2400 bds
02
9600 bds
01
4800 bds
05
115200 bds
04
38400 bds
03
19200 bds
CPE 300 transmitter configuration via remote control / Modbus