5. F 200 : Configuration of the channels and
measurement units
This folder allows to activate the channels and to configure the measurement unit for each channel.
5.1.
Activate a channel
The transmitter is powered on.
➢
Press
OK
.
➢
Enter the activation code
(see page 9).
➢
Press
OK.
➢
Press Up key to go to the F 200 folder.
➢
Press twice
OK.
“ON”
or “
OFF”
displays below
“F200”
.
➢
Press
OK.
➢
Press Up and Down keys to select :
•
“ON” :
activated channel
•
“OFF” :
deactivated channel
➢
Press
OK.
The last zero of F200 flashes.
The
“F200”
folder allows to activate the channel 1 of the transmitter.
To activate the channels 2 and 3 go to the following folders :
•
F210 for the channel 2
•
F220 for the channel 3
➢
Perform the same activation procedure as for the channel 1.
5.2.
Assign a measurement unit to a channel
The transmitter is powered on and a channel is activated.
The
“F200”
folder flashes.
➢
Press Up key.
The
“F201”
sub folder is displayed with the unit corresponding to the channel 1 below.
➢
Press
OK
.
The unit is flashing.
➢
Press Up and Down keys to select the required unit.
➢
Press
OK.
The sign
“----”
indicates that the channel is deactivated.
The
“F201”
sub folder allows to select the unit of the channel 1.
To select the unit of the channels 2 and 3 go to the following folders :
•
F211 for channel 2
•
F221 for channel 3
➢
Perform the same unit selection procedure as for the channel 1.