CONFIG Settings
CF23 SCPI communication error display parameter
Selects whether to display communication errors. The errors are only displayed when you are
using the SCPI language.
CF24 Multichannel (VMCB) domain number parameter
Set the multichannel domain number. PWXs that have the same domain number perform
multichannel operations. If you do not want to use the multichannel function, set this to 0 (this
is the factory default setting).
If 5700 or DCS emulation is selected, you cannot use multichannel. This parameter is applied
when you turn the POWER switch off and on or when you execute CF34.
For details on the multichannel function, see the Communication Interface Manual on the
included CD-ROM.
CF25 Multichannel (VMCB) channel number
Set the multichannel channel number. Specify a unique number on the network. If you do not
want to use the multichannel function, set this to 0 (this is the factory default setting).
If 5700 or DCS emulation is selected, you cannot use multichannel.
This parameter is applied when you turn the POWER switch off and on or when you execute
CF34.
For details on the multichannel function, see the Communication Interface Manual on the
included CD-ROM.
CF30 DHCP parameter
Selects whether or not to obtain an IP address from a DHCP server. If you are using a fixed
IP address, set this to “oFF.”
This parameter is applied when you restart the PWX750ML or when you execute CF34.
Value
Parameter description
oFF
SCPI communication errors are not displayed (factory default setting)
on
SCPI communication errors are displayed.
Value
Parameter description
0
The multichannel function is not used (factory default setting).
1 to 255
The domain number when the multichannel function is used.
Value
Parameter description
0
The PWX is used as a master unit on the multichannel network (factory default
setting).
1 to 30
The PWX is used as a slave unit with this channel number on the multichannel
network
Value
Parameter description
oFF
A DHCP server is not used.
on
A DHCP server is used (factory default setting).
Содержание PWX750ML
Страница 6: ...6 PWX Appendix A Options 100 B Troubleshooting 102...
Страница 52: ...52 PWX This page is intentionally blank...
Страница 80: ...80 PWX This page is intentionally blank...
Страница 81: ...Maintenance This chapter explains how to perform cali bration DELETE...
Страница 84: ...84 PWX This page is intentionally blank...
Страница 85: ...Specifications This chapter contains the specifications and gives the dimensions of the PWX750ML...
Страница 99: ...Appendix A Options B Troubleshooting...
Страница 106: ...106 PWX This page is intentionally blank...
Страница 109: ......