![Kikusui PWX750ML Скачать руководство пользователя страница 18](http://html1.mh-extra.com/html/kikusui/pwx750ml/pwx750ml_user-manual_1966826018.webp)
18
PWX
Connecting to the Output Terminals
1
Turn the POWER switch off.
Check that there is no voltage across the output terminals.
2
Connect one end of the included chassis connection wire to the chassis
terminal, and then connect the other end of the wire to the negative or
positive output terminal.
Use the screw that is attached to the PWX750ML to connect the wire to the chassis
terminal. Use the screw that is attached to the output terminal to connect the wire to
the output terminal.
3
Attach crimping terminals to the load cables.
The output terminals have bolt holes (M6) for connecting the load cables. Use crimp-
ing terminals that are designed for M6 bolts.
4
Use the included bolt set to connect the load cables to the output termi-
nals.
Connect the positive cable to the positive output terminal and the negative cable to
the negative output terminal.
WARNING
Risk of electric shock.
• Turn the POWER switch off before you touch the OUTPUT terminals.
• Even if you turn the output off or turn the POWER switch off, if the bleeder on/off set-
ting (CF11) is set to “oFF,” the voltage that was present when the output was on will
remain at the output terminals. Set the bleeder on/off setting to “on” before you
touch the output terminals.
• Regardless of whether load cables are connected to the output terminals, be sure to
attach the OUTPUT terminal cover before turning the POWER switch on.
- terminal
Chassis terminal
+ terminal
Screw (M3)
Screw (M4)
Chassis connection wire
Use an M3 screw and an
M4 screw to connect the
wire.
Crimping terminal
Bolt (M6)
Spring washer
Washer
Nut
Use the M6 bolt set to
connect the cables.
Содержание PWX750ML
Страница 6: ...6 PWX Appendix A Options 100 B Troubleshooting 102...
Страница 52: ...52 PWX This page is intentionally blank...
Страница 80: ...80 PWX This page is intentionally blank...
Страница 81: ...Maintenance This chapter explains how to perform cali bration DELETE...
Страница 84: ...84 PWX This page is intentionally blank...
Страница 85: ...Specifications This chapter contains the specifications and gives the dimensions of the PWX750ML...
Страница 99: ...Appendix A Options B Troubleshooting...
Страница 106: ...106 PWX This page is intentionally blank...
Страница 109: ......