background image

9

6. Limitations Of Smoke Alarms

 WARNING:  pLEASE READ CAREfULLy AND THOROUGHLy

  

Life safety from fire in residential occupancies is based primarily on early notification to occupants of the 
need to escape, followed by the appropriate egress actions by those occupants.

  

There are situations where a smoke alarm may not be effective to protect against fire as stated in the NFPA 
Standard 72. For instance:

 

a) smoking in bed

 

b) leaving children home alone

 

c) cleaning with flammable liquids, such as gasoline

  

Fire warning systems for dwelling units are capable of protecting about half of the occupants in potentially 
fatal fires.  A smoke alarm may not be effective in some situations, such as during incendiary fires where the 
fire grows so rapidly that an occupant’s egress is blocked even with properly located smoke alarms, or when 
victims are intimate with the fire (for example, when a person’s clothes catch fire while cooking), too old or 
young, or physically or mentally impaired such that they cannot escape even when warned early enough 
that escape should be possible. For these people, additional strategies such as protection-in-place or assist-
ed escape or rescue are necessary.

  

For maximum detection of the various types of fires that can occur within the home, including fast flaming 
and slow smoldering, it is recommended that multi criteria smoke alarms be installed. This model meets 
the latest residential smoke alarm standards, which includes enhanced resistance to nuisance alarms from 
cooking.

  

A battery powered alarm must have a battery of the specified type, in good condition and installed properly 
(this model has a sealed battery).

  

Smoke alarms must be tested regularly to make sure the battery and the alarm circuits are in good operating 
condition.

  

Smoke alarms cannot provide an alarm if smoke does not reach the alarm. Therefore, smoke alarms may not sense 
fires starting in chimneys, within walls, on roofs, on the other side of a closed door or other obstruction.

  

If the alarm is located outside the bedroom or on a different floor, it may not wake up a sound sleeper.

  

The use of alcohol or drugs may also impair one’s ability to hear the smoke alarm. For maximum protection, 
a smoke alarm should be installed in each sleeping area on every level of a home.

This alarm is not intended to alert hearing impaired individuals.

Содержание TRUSENSE SMOKE 3050-VAS10

Страница 1: ...t Model 3050 VAS10 120V HARDWIRE INTERCONNECT 10 year battery backup VOICE ALARM SMOKE ALARM P N 1328 7201 00 Rev A 10 YEAR SMOKE ALARM P U S H B U T T O N TO TEST WEEKLY O R T O H U S H A d v a n c e...

Страница 2: ...It is not designed for use in a recreational vehicle RV or boat Note Please thoroughly read this user guide and save the document for future reference and to pass on to any subsequent owner The Natio...

Страница 3: ...roduction Product Features And Specifications 8 6 Limitations Of Smoke Alarms 9 7 Recommended Locations For Smoke Alarms 10 8 Locations To Avoid 13 9 Wiring Installation Activation 14 10 Operation And...

Страница 4: ...ny inside door without first feeling its surface If hot or if you see smoke seeping through cracks don t open that door Instead use your alternate exit If the inside of the door is cool place your sho...

Страница 5: ...for Alert small children in the home as well as anyone else that might have difficulty recognizing the impor tance of the alarm sounding or that might have difficulty leaving the area without help Do...

Страница 6: ...ed a smoke alarm event Red LED blink every 16 sec After button push voice Smoke previously detected NOTE On DC power alarm memory is only retained for 24 hrs Push button to clear Alarm Memory Smoke Al...

Страница 7: ...c Chirp every 30 sec voice Smoke Sensor Error every 60 sec After 1 hour on DC power voice occurs only after button is pushed See Cleaning Your Alarm section Push button once to attempt to reset the un...

Страница 8: ...prior to installing the unit NOTE AC power must be connected to obtain the full 10 year battery and unit life Product Features and Specifications Temperature Operating Range 40 F 4 4 C to 100 F 37 8...

Страница 9: ...e For these people additional strategies such as protection in place or assist ed escape or rescue are necessary For maximum detection of the various types of fires that can occur within the home incl...

Страница 10: ...closed The closed door may prevent an alarm not located in that room from waking the sleeper Smoke heat and combustion products rise to the ceiling and spread horizontally Mounting the smoke alarm on...

Страница 11: ...permitted for smoke alarms and smoke detectors on tray shaped ceilings NFPA 72 states Smoke alarms in rooms with ceiling slopes greater than 1 ft in 8 ft 3m in 2 4 m horizontally shall be located on...

Страница 12: ...mes have been designed and built to be energy efficient Install smoke alarms as recommended above In older mobile homes that are not well insulated compared to present standards extreme heat or cold c...

Страница 13: ...F or rise above 100 F such as garages and unfinished attics In dusty areas Dust particles may cause nuisance alarms or a failure to alarm In very humid areas above 95 RH non condensing as moisture or...

Страница 14: ...Electrical Code ANSI NFPA 70 NFPA 72 and or any other codes having jurisdiction in your area The multiple station interconnect wiring to the alarms must be run in the same raceway or cable as the AC...

Страница 15: ...ot be operated from power derived from a square wave modified square wave or modified sine wave inverter These types of inverters are sometimes used to supply power to the structure in off grid in sta...

Страница 16: ...remote signaling devices and or relay modules see below for details on interconnecting Kidde devices Figure 9 C illustrates interconnection wiring Improper connection will result in damage to the alar...

Страница 17: ...te the battery to eliminate the false low battery trouble condition chirps and voice Attach unit to mounting bracket very soon after applying AC power to avoid false low battery notification NOTE The...

Страница 18: ...lectronic circuitry horn speaker and battery are working If the alarm or voice does not sound or gives erratic or low volume sound the unit must be replaced See Perma nently Disable Alarm Discharge Ba...

Страница 19: ...nuisance alarms Cigarette smoke will not normally cause the unit to alarm unless the smoke is blown directly into the alarm Combustion particles from cooking may set off the alarm if it is located to...

Страница 20: ...THE ALARM FOR ANY REASON Do not try to repair the alarm yourself Low Battery This alarm is equipped with a low battery monitor circuit If the battery capacity is nearing the point where it can no lon...

Страница 21: ...e for disposal by draining the battery Figures 13 A top and 13 B bottom 13 Permanently Disable Alarm Discharge Battery WARNING Failure to DISCHARGE alarm battery as instructed prior to disposal may cr...

Страница 22: ...could damage the alarm If the alarm is in Fault mode the alarm may be in need of cleaning After cleaning press the button If the fault does not clear the alarm needs to be replaced Never use detergent...

Страница 23: ...to test your plan before an emergency You may not be able to reach your children It is important they know what to do Familiarize everyone with the sounds of the smoke alarm and train them to leave y...

Страница 24: ...can result in improper operation California State Fire Marshal Early warning fire detection is best achieved by the installation of fire detection equipment in all rooms and areas of the household as...

Страница 25: ...15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interferenc...

Страница 26: ...ity and fitness for a particular purpose are limited in duration to the above warranty period In no event shall the Manu facturer be liable for loss of use of this product or for any indirect special...

Страница 27: ...27 QUESTIONS OR FOR MORE INFORMATION Call Kidde Product Support line at 1 800 880 6788 or contact us at www kidde com Kidde 1016 Corporate Park Drive Mebane NC 27302 Made in China...

Отзывы: