For your convenience, write down the following 

information. If you call our Consumer Hotline, 

these are the first questions you will be asked.

Smoke Alarm Model Number
(located on back of alarm):

Date Code (located on back of alarm). 
National Fire Protection Association
(NFPA) and the manufacturer
recommends replacing this alarm
ten years from the date code:

Date of Purchase:

Where Purchased:

AC Wire-in Single and/or Multiple Station (up to 24 Devices) 
Photoelectric Smoke Alarm with 9 Volt Battery Back Up and 
“HUSH” Control to temporarily silence nuisance alarms.

Thank you for purchasing this smoke alarm. It is an important 
part of your family’s home safety plan. You can trust this product 
to provide the highest quality safety protection. We know you 
expect nothing less when the lives of your family are at stake. 
Kidde alarms and accessories CAN ONLY BE interconnected with 
other Kidde alarms and accessories as well as specified brands and 
models of interconnect compatible alarms. Connection of Kidde 
products to a non-specified manufacturer’s interconnect system, 
or connection with non-specified equipment from another manu-
facturer into an existing Kidde system could result in nuisance 
alarming, failure to alarm, or damage to one or all of the devices 
in the interconnect system. Refer to the User’s Guide supplied with 
each Kidde product for interconnect compatible models, brands, 
and devices. Refer to the wiring instructions in section 3 for NFPA 
initiating device limits.

Smoke Alarm User’s Guide

21008164-EN Rev A

1375-7213-00

P12040

For model: P12040

SIGNALING

LISTED

UL

1375-7213-00(21008164-EN A).indd   1

1375-7213-00(21008164-EN A).indd   1

2010.10.7   2:06:22 PM

2010.10.7   2:06:22 PM

Содержание P12040

Страница 1: ...u expect nothing less when the lives of your family are at stake Kidde alarms and accessories CAN ONLY BE interconnected with other Kidde alarms and accessories as well as specified brands and models...

Страница 2: ...thest from the exit If more than one sleeping area exists locate addi tional alarms in each sleeping area Locate additional alarms to monitor any stairway as stairways act like chimneys for smoke and...

Страница 3: ...d peaked or cathedral ceilings at or within 3 ft 0 9m of the highest point measured hori zontally NFPA 72 states Smoke alarms in rooms with ceiling slopes greater than 1 ft in 8 ft 3m in 2 4m horizont...

Страница 4: ...USE 2 LOCATIONS TO AVOID In the garage Products of combustion are present when you start your automobile Less than 4 10cm from the peak of an A frame type ceiling In an area where the temperature may...

Страница 5: ...nverters These types of inverters are sometimes used to supply power to the structure in off grid installations such as solar or wind derived power sources These power sources produce high peak voltag...

Страница 6: ...ndard UL listed household wire as required by local codes available at all electrical supply stores and most hardware stores FIGURE 4 INTERCONNECT WIRING DIAGRAM WIRES ON ALARM HARNESS CONNECTED TO Bl...

Страница 7: ...e that the mounting screws are positioned in the small ends of the keyholes before tightening the screws see figure 5 5 Plug the AC QUICK CONNECTOR into the back of the alarm see figure 6 making sure...

Страница 8: ...H CONTROL The HUSH feature has the capability of temporarily desensitizing the alarm circuit for approximately 10 minutes This feature is to be used only when a known alarm condition such as smoke fro...

Страница 9: ...m which senses the smoke or is being tested the originating unit will flash rapidly All other units in the interconnect system will sound an alarm but their red LED s will NOT flash rapidly The green...

Страница 10: ...sance alarms For more information refer to section 4 OPERATION AND TESTING 6 MAINTENANCE IF TAMPER RESIST PIN HAS BEEN USED REFER TO TAMPER RESIST LOCKING PIN IN SECTION 3 FOR PIN REMOVAL INSTRUCTIONS...

Страница 11: ...ADY 1222 GOLD PEAK 1604P OR 1604S Alkaline Type ENERGIZER 522 DURACELL MN1604 MX1604 GOLD PEAK 1604A PANASONIC 6AM6 6AM 6 6AM 6PI 6AM6X and 6LR61 GA Lithium Type ULTRALIFE U9VL J NOTE WEEKLY TESTING I...

Страница 12: ...are often unpredictable For maximum protection Kidde recom mends that both Ionization and Photoelectric alarms be installed A battery powered alarm must have a battery of the specified type in good c...

Страница 13: ...l occupants to test your plan before an emergency You may not be able to reach your chil dren It is important they know what to do Current studies have shown smoke alarms may not awaken all sleeping i...

Страница 14: ...in existing one and two family dwelling units 2 Outside of each separate sleeping area in immediate vicinity of the sleeping rooms 3 On each level of the dwelling unit includ ing basements Exception I...

Страница 15: ...smoke alarm installed in each separate sleeping area in the vicinity of but outside of the bedrooms and heat or smoke alarms in the living rooms dining rooms bedrooms kitch ens hallways attics furnace...

Страница 16: ...ANY CASE EXCEED THE COST OF REPLACEMENT OF SMOKE ALARM AND IN NO CASE SHALL KIDDE OR ANY OF ITS PARENT OR SUBSIDIARY CORPORATIONS BE LIABLE FOR CONSEQUENTIAL LOSS OR DAMAGES RESULTING FROM THE FAILUR...

Отзывы: