3. Make sure that the mounting screws are positioned in the small
ends of the keyholes before tightening the screws.
4. Install the alarm on the mounting plate
and rotate the alarm in the direction indi-
cated by the "ON" arrow on the cover
until the alarm ratchets into place (this
ratcheting function allows for aesthetic
alignment). NOTE: The alarm will mount
to the bracket in 4 positions (every 90
degrees). When wall mounting, make
sure the battery box is at the bottom of
the unit. (see Figure 7)
5. Be sure the battery is installed correctly and the battery compart-
ment is closed completely.  See section 6 for battery installation
instructions.

CAUTION:  THE BATTERY COMPARTMENT WILL NOT CLOSE
WITHOUT A BATTERY INSTALLED PROPERLY.  REMOVAL OF
THE BATTERY WILL RENDER THE ALARM INOPERATIVE.

6. Test the unit to ensure proper operation by pressing the Test

Button for a minimun of 5 seconds.

CAUTION:  Due to the loudness (85 decibels) of the alarm,
always stand an arms length away from the unit when testing.

Tamper Resist Feature

Battery Carrier Tamper Resist Feature

This alarm has a battery carrier tamper resist feature, which
helps prevent the battery carrier from being opened. This feature
helps prevent the removal of the battery from this device (which
will render the device inoperative).

3. Installation Instructions

FIGURE 7

Install

Remove

FIGURE 6

FIGURE 5

Alignment Marks

A

A

When mounting in a hallway, the “A”
line should be parallel with the hallway.  

FIGURE 5A

  

  

 

  

 

Содержание I9070

Страница 1: ...0 SIGNALING LISTED UL ATTENTION Please take a few minutes to thoroughly read this user s guide which should be saved for future reference and passed on to any subsequent owner Smoke Alarm User s Guide...

Страница 2: ...hese steps and review with all family members Alert small children in the home Leave immediately by your escape plan Every second counts so don t waste time getting dressed or picking up valuables In...

Страница 3: ...E EACH TRIP AND AT LEAST ONCE A WEEK DURING USE CAUTION DUE TO THE LOUDNESS OF THE ALARM 85 DECIBELS ALWAYS STAND AN ARMS LENGTH AWAY FROM THE UNIT WHEN TESTING CAUTION BEFORE USING THE ALARM HUSH FEA...

Страница 4: ...vice and Warranty This alarm detects products of combustion using the ionization tech nique It contains 0 9 microcurie of Americium 241 a radioactive materi al see section 9 Distributed under U S NRC...

Страница 5: ...ocated in that room from waking the sleeper Smoke heat and combustion products rise to the ceiling and spread horizontally Mounting the smoke alarm on the ceiling in the center of the room places it c...

Страница 6: ...peak of the ceiling measured horizontally see figure 2 Install Smoke Alarms on tray shaped ceilings coffered ceilings on the highest portion of the ceiling or on the sloped portion of the ceiling with...

Страница 7: ...cent lights Electronic noise may cause nuisance alarms Smoke alarms are not to be used with detector guards unless the combination alarm and guard has been evaluated and found suitable for that purpos...

Страница 8: ...nstructions CAUTION THE BATTERY COMPARTMENT WILL NOT CLOSE WITHOUT A BATTERY INSTALLED PROPERLY REMOVAL OF THE BATTERY WILL RENDER THE ALARM INOPERATIVE 6 Test the unit to ensure proper operation by p...

Страница 9: ...slide the switch towards the bottom of the product label The battery carri er can now be opened and the battery changed FIGURE 8 4 Operation and Testing OPERATION The smoke alarm is operating once fre...

Страница 10: ...EXISTS LED INDICATOR This smoke alarm is equipped with a red LED indicator with two modes of operation Standby Condition The red LED will flash every 40 seconds to indicate that the smoke alarm is ope...

Страница 11: ...tery carrier Completely press the battery carrier down into the alarm and release the battery carrier will lock into the closed position A missing or improperly installed battery will prevent the batt...

Страница 12: ...TERIES SPECIFIED USE OF DIFFERENT BATTERIES MAY HAVE A DETRIMENTAL EFFECT ON THE SMOKE ALARM CLEANING YOUR ALARM YOUR ALARM SHOULD BE CLEANED AT LEAST ONCE A YEAR To clean your alarm remove it from th...

Страница 13: ...aximum protection Kidde recommends that both Ionization and Photoelectric alarms be installed A battery powered alarm must have a battery of the specified type in good condition and installed properly...

Страница 14: ...They must wake up in order to execute the escape plan Practice allows all occupants to test your plan before an emergency You may not be able to reach your children It is important they know what to d...

Страница 15: ...not provide reliable early warning protection for those areas separated by a door from the areas protected by the required smoke alarms For this reason the use of additional smoke alarms for those are...

Страница 16: ...RATIONS ARISING FROM THE SALE OF THIS SMOKE ALARM OR UNDER THE TERMS OF THIS LIMITED WARRANTY SHALL NOT IN ANY CASE EXCEED THE COST OF REPLACEMENT OF SMOKE ALARM AND IN NO CASE SHALL KIDDE OR ANY OF...

Страница 17: ...QUESTIONS OR FOR MORE INFORMATION Call our Consumer Hotline at 1 800 880 6788 or contact us at our website at www kidde com Kidde 1016 Corporate Park Drive Mebane NC 27302...

Отзывы: