10. NFPA Required Protection

The National Fire Protection Association’s Standard 72 provides the following
information:

Smoke Detection - Where required by applicable laws, codes, or standards
for a specific type of occupancy, approved single- and multiple-station
smoke alarms shall be installed as follows:

(1) In all sleeping rooms and guest rooms

(2) Outside of each separate dwelling unit sleeping area, within 6.4 m (21 ft)
of any door to a sleeping room, the distance measured along a path of travel

(3) On every level of a dwelling unit, including basements

(4) On every level of a residential board and care occupancy (small facility),
including basements and excluding crawl spaces and unfinished attics

(5) In the living area(s) of a guest suite

(6) In the living area(s) of a residential board and care occupancy (small facility) 

Are More Smoke Alarms Desirable? The required number of smoke alarms
might not provide reliable early warning protection for those areas separated
by a door from the areas protected by the required smoke alarms. For this
reason, the use of additional smoke alarms for those areas for increased pro-
tection is recommended. The additional areas include the basement, bed-
rooms, dining room, furnace room, utility room, and hallways not protected
by the required smoke alarms. The installation of smoke alarms in kitchens,
attics (finished or unfinished), or garages is not normally recommended,
because these locations occasionally experience conditions that can result in
improper operation.

11. CAUTION (AS REQUIRED BY THE CALIFORNIA 

STATE FIRE MARSHAL)

Ionization type smoke alarms use a very small amount of a radioac-
tive element in the sensing chamber to enable detection of visible
and invisible combustion products. The radioactive element is safely
contained in the chamber and requires no adjustments or mainte-
nance.  This smoke alarm meets or exceeds all government stan-
dards.  It is manufactured and distributed under license from the U.S.
Nuclear Regulatory Commission.

  

  

 

  

 

Содержание I9070

Страница 1: ...0 SIGNALING LISTED UL ATTENTION Please take a few minutes to thoroughly read this user s guide which should be saved for future reference and passed on to any subsequent owner Smoke Alarm User s Guide...

Страница 2: ...hese steps and review with all family members Alert small children in the home Leave immediately by your escape plan Every second counts so don t waste time getting dressed or picking up valuables In...

Страница 3: ...E EACH TRIP AND AT LEAST ONCE A WEEK DURING USE CAUTION DUE TO THE LOUDNESS OF THE ALARM 85 DECIBELS ALWAYS STAND AN ARMS LENGTH AWAY FROM THE UNIT WHEN TESTING CAUTION BEFORE USING THE ALARM HUSH FEA...

Страница 4: ...vice and Warranty This alarm detects products of combustion using the ionization tech nique It contains 0 9 microcurie of Americium 241 a radioactive materi al see section 9 Distributed under U S NRC...

Страница 5: ...ocated in that room from waking the sleeper Smoke heat and combustion products rise to the ceiling and spread horizontally Mounting the smoke alarm on the ceiling in the center of the room places it c...

Страница 6: ...peak of the ceiling measured horizontally see figure 2 Install Smoke Alarms on tray shaped ceilings coffered ceilings on the highest portion of the ceiling or on the sloped portion of the ceiling with...

Страница 7: ...cent lights Electronic noise may cause nuisance alarms Smoke alarms are not to be used with detector guards unless the combination alarm and guard has been evaluated and found suitable for that purpos...

Страница 8: ...nstructions CAUTION THE BATTERY COMPARTMENT WILL NOT CLOSE WITHOUT A BATTERY INSTALLED PROPERLY REMOVAL OF THE BATTERY WILL RENDER THE ALARM INOPERATIVE 6 Test the unit to ensure proper operation by p...

Страница 9: ...slide the switch towards the bottom of the product label The battery carri er can now be opened and the battery changed FIGURE 8 4 Operation and Testing OPERATION The smoke alarm is operating once fre...

Страница 10: ...EXISTS LED INDICATOR This smoke alarm is equipped with a red LED indicator with two modes of operation Standby Condition The red LED will flash every 40 seconds to indicate that the smoke alarm is ope...

Страница 11: ...tery carrier Completely press the battery carrier down into the alarm and release the battery carrier will lock into the closed position A missing or improperly installed battery will prevent the batt...

Страница 12: ...TERIES SPECIFIED USE OF DIFFERENT BATTERIES MAY HAVE A DETRIMENTAL EFFECT ON THE SMOKE ALARM CLEANING YOUR ALARM YOUR ALARM SHOULD BE CLEANED AT LEAST ONCE A YEAR To clean your alarm remove it from th...

Страница 13: ...aximum protection Kidde recommends that both Ionization and Photoelectric alarms be installed A battery powered alarm must have a battery of the specified type in good condition and installed properly...

Страница 14: ...They must wake up in order to execute the escape plan Practice allows all occupants to test your plan before an emergency You may not be able to reach your children It is important they know what to d...

Страница 15: ...not provide reliable early warning protection for those areas separated by a door from the areas protected by the required smoke alarms For this reason the use of additional smoke alarms for those are...

Страница 16: ...RATIONS ARISING FROM THE SALE OF THIS SMOKE ALARM OR UNDER THE TERMS OF THIS LIMITED WARRANTY SHALL NOT IN ANY CASE EXCEED THE COST OF REPLACEMENT OF SMOKE ALARM AND IN NO CASE SHALL KIDDE OR ANY OF...

Страница 17: ...QUESTIONS OR FOR MORE INFORMATION Call our Consumer Hotline at 1 800 880 6788 or contact us at our website at www kidde com Kidde 1016 Corporate Park Drive Mebane NC 27302...

Отзывы: