12. Service and Warranty

TEN YEAR LIMITED WARRANTY

Kidde warrants to the original purchaser that the enclosed smoke alarm will
be free from defects in material and workmanship or design under normal
use and service for a period of ten (10) years from the date of purchase.
The obligation of Kidde under this warranty is limited to repairing or replac-
ing the smoke alarm or any part which we find to be defective in material,
workmanship or design, free of charge to the customer, upon sending the
smoke alarm with proof of date of purchase, postage and return postage
prepaid, to Warranty Service Department, Kidde, 1016 Corporate Park Dr.,
Mebane, NC 27302.

This warranty shall not apply to the smoke alarm if it has been damaged,
modified, abused or altered after the date of purchase or if it fails to oper-
ate due to improper maintenance or inadequate AC or DC electrical power.

THE LIABILITY OF KIDDE OR ANY OF ITS PARENT OR SUBSIDIARY CORPO-
RATIONS ARISING FROM THE SALE OF THIS SMOKE ALARM OR UNDER
THE TERMS OF THIS LIMITED WARRANTY SHALL NOT IN ANY CASE
EXCEED THE COST OF REPLACEMENT OF SMOKE ALARM AND, IN NO
CASE, SHALL KIDDE OR ANY OF ITS PARENT OR SUBSIDIARY CORPORA-
TIONS BE LIABLE FOR CONSEQUENTIAL LOSS OR DAMAGES RESULTING
FROM THE FAILURE OF THE SMOKE ALARM OR FOR BREACH OF THIS OR
ANY OTHER WARRANTY, EXPRESS OR IMPLIED, EVEN IF THE LOSS OR
DAMAGE IS CAUSED BY THE COMPANY’S NEGLIGENCE OR FAULT.

Since some states do not allow limitations on the duration of an implied
warranty or do not allow the exclusion or limitation of incidental or conse-
quential damages, the above limitations or exclusions may not apply to
you.  While this warranty gives you specific legal rights, you may also have
other rights which vary from state to state.

The above warranty may not be altered except in writing signed by both
parties hereto.

If after reviewing this manual you feel that your smoke alarm is defective
in any way, do not tamper with the unit. 
Return for servicing to: KIDDE Safety, 1016 Corporate Park Dr., Mebane,
NC 27302. 800-880-6788 (See Warranty for in-warranty returns)

  

  

 

  

 

Содержание I9070

Страница 1: ...0 SIGNALING LISTED UL ATTENTION Please take a few minutes to thoroughly read this user s guide which should be saved for future reference and passed on to any subsequent owner Smoke Alarm User s Guide...

Страница 2: ...hese steps and review with all family members Alert small children in the home Leave immediately by your escape plan Every second counts so don t waste time getting dressed or picking up valuables In...

Страница 3: ...E EACH TRIP AND AT LEAST ONCE A WEEK DURING USE CAUTION DUE TO THE LOUDNESS OF THE ALARM 85 DECIBELS ALWAYS STAND AN ARMS LENGTH AWAY FROM THE UNIT WHEN TESTING CAUTION BEFORE USING THE ALARM HUSH FEA...

Страница 4: ...vice and Warranty This alarm detects products of combustion using the ionization tech nique It contains 0 9 microcurie of Americium 241 a radioactive materi al see section 9 Distributed under U S NRC...

Страница 5: ...ocated in that room from waking the sleeper Smoke heat and combustion products rise to the ceiling and spread horizontally Mounting the smoke alarm on the ceiling in the center of the room places it c...

Страница 6: ...peak of the ceiling measured horizontally see figure 2 Install Smoke Alarms on tray shaped ceilings coffered ceilings on the highest portion of the ceiling or on the sloped portion of the ceiling with...

Страница 7: ...cent lights Electronic noise may cause nuisance alarms Smoke alarms are not to be used with detector guards unless the combination alarm and guard has been evaluated and found suitable for that purpos...

Страница 8: ...nstructions CAUTION THE BATTERY COMPARTMENT WILL NOT CLOSE WITHOUT A BATTERY INSTALLED PROPERLY REMOVAL OF THE BATTERY WILL RENDER THE ALARM INOPERATIVE 6 Test the unit to ensure proper operation by p...

Страница 9: ...slide the switch towards the bottom of the product label The battery carri er can now be opened and the battery changed FIGURE 8 4 Operation and Testing OPERATION The smoke alarm is operating once fre...

Страница 10: ...EXISTS LED INDICATOR This smoke alarm is equipped with a red LED indicator with two modes of operation Standby Condition The red LED will flash every 40 seconds to indicate that the smoke alarm is ope...

Страница 11: ...tery carrier Completely press the battery carrier down into the alarm and release the battery carrier will lock into the closed position A missing or improperly installed battery will prevent the batt...

Страница 12: ...TERIES SPECIFIED USE OF DIFFERENT BATTERIES MAY HAVE A DETRIMENTAL EFFECT ON THE SMOKE ALARM CLEANING YOUR ALARM YOUR ALARM SHOULD BE CLEANED AT LEAST ONCE A YEAR To clean your alarm remove it from th...

Страница 13: ...aximum protection Kidde recommends that both Ionization and Photoelectric alarms be installed A battery powered alarm must have a battery of the specified type in good condition and installed properly...

Страница 14: ...They must wake up in order to execute the escape plan Practice allows all occupants to test your plan before an emergency You may not be able to reach your children It is important they know what to d...

Страница 15: ...not provide reliable early warning protection for those areas separated by a door from the areas protected by the required smoke alarms For this reason the use of additional smoke alarms for those are...

Страница 16: ...RATIONS ARISING FROM THE SALE OF THIS SMOKE ALARM OR UNDER THE TERMS OF THIS LIMITED WARRANTY SHALL NOT IN ANY CASE EXCEED THE COST OF REPLACEMENT OF SMOKE ALARM AND IN NO CASE SHALL KIDDE OR ANY OF...

Страница 17: ...QUESTIONS OR FOR MORE INFORMATION Call our Consumer Hotline at 1 800 880 6788 or contact us at our website at www kidde com Kidde 1016 Corporate Park Drive Mebane NC 27302...