background image

Document NO.

RD-558A-39-001                                       

1

 / 

5

                                   

Version: F       

   
   

EN14604:2005/AC:2008 

Smoke Alarm User Manual 

Model number: GS558A   

   

Ref

ST558           

 

Thank  you  for  purchasing  our  smoke  alarm

 

with  wireless  and 

heat  detection

.  Please  take  a  few  minutes  to  read  the  user’s 

manual thoroughly and familiarize yourself and your family with 

its operation. And save it for future reference.     

 

 

Product Specifications: 

Power 

:  DC2*1.5V  Alkaline  AA  battery         

(Gold  Peak  Group: 

GP 15A LR6 or Energize: E91 or Raymax: LR6) 

Operation current 

<4uA (standby), <40mA (alarm)           

Alarm volume 

: >85dB(A) at 3 meters. 

Smoke sensitivity 

: 0.100-0.163dB/m 

Heat sensitivity: 

54-70

 

Local smoke alarm sound pattern:   

BI  0.5s  -  pause  0.5s 

  BI  0.5s 

  pause  0.5s 

  BI  0.5s 

 

pause  1.5s,  with  the  red  LED  flash,  repeat  this  alarm 

pattern. 

Local heat alarm sound pattern:   

BI 0.2s - pause 0.1s, with the red LED flash, repeat this 

alarm pattern. 

Wireless alarm sound pattern:   

Bi - Bi - pause 1.2s, with the red LED flash, repeat   

this alarm pattern. 

Description: 

The unit is a photoelectric 3V DC smoke alarm. It is operated by 

3v AA Alkaline battery. With the photoelectric technology, it is 

more  sensitive  to  detecting  slow  smolder  fires  which  general 

thick, black smoke, little heat and may smolder for hours before 

bursting  into  flames.  The  smoke  alarm  do  not  contain  the 

radioactive material which is harmless to the environment. 

The smoke alarm should be installed in every room (except the 

bathroom),  and  every  other  area  of  the  home,  making  sure  the 

people in the home will be able to hear and respond to the alarm 

sound.  For  minimum  protection  you  should  fit  an  alarm  in  the 

hallway  between  the  living  areas  and  sleeping  areas.  Place  the 

unit near  to  the living areas as possible and ensure  the  alarm  is 

audible when the bedrooms are occupied. 

Typical single storey dwelling with recommended: 

Install a smoke alarm on the ceiling inside each bedroom and in 

the  hallway  outside  each  separate  sleeping  area.  If  a  bedroom 

area hallway is more than 30 feet long, install a smoke alarm at 

each  end.  If  there  is  a  basement:  install  a  smoke  alarm  on  the 

basement ceiling at the bottom of the stairwell. 

Typical multi-storey dwelling with recommended protection.   

Install a smoke alarm on the ceiling inside each bedroom and in 

the  hallway  outside  each  separate  sleeping  area.  If  a  bedroom 

area hallway is more than 30 feet long, install a smoke alarm at 

each end install a smoke alarm at the top of a first 

 to- second 

floor stairwell. 

Important Safety Information: 

1:

 

The test button accurately tests smoke alarm functions. Do not 

use any other test method. Test smoke alarm weekly to ensure 

proper operation. 

2: Do not remove or disconnect battery. This will take out your 

protection. Open windows or fan the air around smoke alarm 

for silence it. 

3:  This  smoke  alarm  should  be  installed  only  by  a  licensed, 

qualified  electrician.  Observe  and  follow  all  local  and 

national electrical and building codes for installation. 

4: This smoke alarm is designed to be used inside a single family 

only.  In  multifamily  buildings,  each  individual  living  unit 

should  have  its  own  smoke  alarms.  Do  not  install  in 

non-residential  buildings.  And  this  smoke  alarm  is  not  a 

substitute for a complete alarm system. 

5: Install a smoke alarm in every room and on every level of the 

home.  Smoke  may  not  reach  the  smoke  alarm  for  many 

reasons.  For  example,  if  a  fire  starts  in  a  remote  part  of  the 

home,  on  another  level,  in  a  chimney,  wall,  roof,  or  on  the 

other side of a closed door, smoke may not reach the smoke 

alarm  in  time  to  alert  household  members.  A  smoke  alarm 

will not promptly detect a fire except in the area or room in 

which it is installed. 

6:  Smoke  alarm  may  not  alert  every  household  member  every 

time. The alarm horn is loud in order to alert individuals to a 

potential danger. However, there may be some circumstances 

where  a  household  member  may  not  hear  the  alarm  (i.e. 

outdoor  or  indoor  noise,  sound  sleepers,  drug  or  alcohol 

usage,  the  hard  of  hearing,  etc.).  If  you  suspect  that  this 

smoke alarm may not alert a household member, install and 

maintain  specialty  smoke  alarms.  Household  member  must 

hear the alarm’s warning sound and quickly respond to it t

reduce  the  risk  of  damage,  injury,  or  death  that  may  result 

from  fire,  If  a  household  member  is  hard  of  hearing,  install 

Summary of Contents for GS558A

Page 1: ... smoke alarm on the basement ceiling at the bottom of the stairwell Typical multi storey dwelling with recommended protection Install a smoke alarm on the ceiling inside each bedroom and in the hallway outside each separate sleeping area If a bedroom area hallway is more than 30 feet long install a smoke alarm at each end install a smoke alarm at the top of a first to second floor stairwell Import...

Page 2: ... alarm using test button The sound pattern is 3 short beeps 1 5seconds pause repeat it If there s no sound output it means that the smoke alarm is faulty or the installing operation is wrong and you should gain the correctly method of disposal through reading TROUBLE SHOOTING NOTE During testing because the unit send the wireless signal may the other smoke detector will alarm Once release the test...

Page 3: ...s for about 1 second release the button the alarm enters the clear code mode Note enter this mode from standby mode press and hold the button for about 16 seconds required b After releasing the button press the button when the red LED lights up release the button when the red LED is off if you hear the sound of BI sound after two cycles that indicates clear code is success the alarm own wireless c...

Page 4: ...product In no case shall company be liable for any incidental or consequential damages for breach of this or any other warranty express or implied whatsoever The bad product can be mailed to the following address with a detail explanation of problem Before you install the alarm please read the instruction Where is the best to be Installed At first you need install one unit in the bedroom and route...

Page 5: ... well on the bracket Test smoke alarm using test button The alarm will sound 3 short beeps 1 5 seconds pause then repeat it until release the button if no sound it indicates a defective alarm you can refer to Trouble shooting for solution or return to your retailer during warranty If you have any questions on installation you can contact your retailer During testing may the other smoke detector wi...