• For mobile home installation, select locations carefully to avoid thermal barriers that may form at the

ceiling.  For more details, see MOBILE HOME INSTALLATION below.

• When mounting an alarm on the ceiling, locate it at a minimum of 4” (10 cm) from the side wal

(see Diagram A).

• When mounting the alarm on the wall, use an inside wall with the top edge of the alarm at a mini-

mum of 4” (10 cm) and a maximum of 12” (30.5 cm) below the ceiling. (see Diagram A).

• Put smoke alarms at both ends of a bedroom hallway or large room if the hallway or room is more

than 30 feet (9.1 m) long.

• Install Smoke Alarms on sloped, peaked or cathedral ceilings at or within 3ft (0.9m)of the highest

point (measured horizontally). NFPA 72 states: “Smoke alarms in rooms with ceiling slopes   greater
than 1 foot in 8 feet (.3m in 2.4m) horizontally shall be located on the high side of the room.”
NFPA 72 states: “A row of alarms shall be spaced and located within 3 ft (0.9m) of the   peak of the
ceiling measured horizontally” (see diagram ”C”).

MOBILE HOME INSTALLATION

Mobile homes built in the past five to seven years have been designed to be energy efficient.  Install
smoke alarms as recommended above (refer to RECOMMENDED LOCATIONS and Diagram A).

In mobile homes that are not well insulated compared to present standards, extreme heat or cold can
be transferred from the outside to the inside through poorly insulated walls and roof.  This may create a
thermal barrier which can prevent the smoke from reaching an alarm mounted on the ceiling.  In such
units, install the smoke alarm on an inside wall with the top edge of the alarm at a minimum of 4” (10
cm) and a maximum of 12” (30.5 cm) below the ceiling (see Diagram A).

If you are not sure about the insulation in your mobile home, or if you notice that the outer walls and
ceiling are either hot or cold, install the alarm on an inside wall.  For minimum protection, install at least
one alarm close to the bedrooms.  For additional protection, see SINGLE FLOOR PLAN in Diagram B.

WARNING: TEST YOUR SMOKE ALARM OPERATION AFTER R.V. OR MOBILE HOME VEHICLE
HAS BEEN IN STORAGE, BEFORE EACH TRIP AND AT LEAST ONCE A WEEK DURING USE.

DIAGRAM “A”

Smoke Alarms for Minimum Protection

Smoke Alarms for Additional Protection

Ionization Type Smoke Alarms with

“Hush” Control or Photoelectric Type

DIAGRAM “B”

3 ft

(0.9m)

3 ft

(0.9m)

HORIZONTAL DISTANCE

FROM PEAK

ANYWHERE
IN THIS  AREA

DIAGRAM “C”

This product is designed to detect products of combustion using the ionization technique.  It contains
0.9 microcurie of Americium 241, a radioactive material. Distributed under U.S. NRC License No. 32-
23858-01E.   Manufactured in compliance with  U.S. NRC safety criteria in 10 CFR 32.27.  The pur-
chaser is exempt from any regulatory requirements.

WARNING! REMOVAL OF THE SMOKE ALARM BATTERY AND DISCONNECTING OR LOSS
OF A.C. POWER WILL RENDER THE SMOKE ALARM INOPERATIVE.

ELECTRICAL RATING: 120 VAC, 60HZ, 80mA maximum per alarm (maximum 80mA for originating unit
with 24 devices interconnected).

IMPORTANT! READ ALL INSTRUCTIONS BEFORE INSTALLATION AND KEEP THIS MANUAL
NEAR THE ALARM FOR FUTURE REFERENCE.

CONTENTS OF THIS MANUAL

1 -- RECOMMENDED LOCATIONS FOR SMOKE ALARMS
2 -- LOCATIONS TO AVOID
3 -- INSTALLATION INSTRUCTIONS
4 -- OPERATION AND TESTING
5 -- NUISANCE ALARMS
6 -- MAINTENANCE
7 -- LIMITATIONS OF SMOKE ALARMS
8 -- GOOD SAFETY HABITS
9 -- NRC INFORMATION

10 -- NFPA PROTECTION STANDARD 72
11 -- CALIFORNIA STATE FIRE MARSHAL REQUIRED INFORMATION
12 -- SERVICE AND WARRANTY

This smoke alarm uses an extremely small amount of radioactive element in the ionization chamber
(see Section 9).  Do not try to repair the smoke alarm yourself.  Refer to the instructions in Section 12
for service.

1. RECOMMENDED LOCATIONS FOR ALARMS

• Locate the first alarm in the immediate area of the bedrooms.  Try to protect the exit path as the

bedrooms are usually farthest from the exit.  If more than one sleeping area exists, locate additional
alarms in each sleeping area.

• Locate additional alarms to protect any stairway as stairways act like chimneys for smoke and heat.

• Locate at least one alarm on every floor level.

• Locate an alarm in every bedroom.

• Locate an alarm in every room where electrical appliances are operated (i.e. portable heaters or

humidifiers).

• Locate an alarm in every room where someone sleeps with the door closed.  The closed door may

prevent the alarm from waking the sleeper.

• Smoke, heat, and combustion products rise to the ceiling and spread horizontally.  Mounting the

smoke alarm on the ceiling in the center of the room places it closest to all points in the room.
Ceiling mounting is preferred in ordinary residential construction. 

Содержание 1285

Страница 1: ...n We know you expect noth ing less when the lives of your family are at stake For your convenience write down the following information If you call our Consumer Hotline these are the first questions you will be asked Smoke Alarm Model Number located on back of alarm Date Code located on back of alarm The National Fire Protection Association NFPA and the manufacturer recommends replacing this alarm...

Страница 2: ...rAdditionalProtection IonizationTypeSmokeAlarmswith Hush ControlorPhotoelectricType DIAGRAM B 3 ft 0 9m 3 ft 0 9m HORIZONTAL DISTANCE FROM PEAK ANYWHERE IN THIS AREA DIAGRAM C This product is designed to detect products of combustion using the ionization technique It contains 0 9 microcurie of Americium 241 a radioactive material Distributed under U S NRC License No 32 23858 01E Manufactured in co...

Страница 3: ...cles may cause nuisance alarms or failure to alarm In very humid areas Moisture or steam can cause nuisance alarms In insect infested areas Smoke alarms should not be installed within 3 ft 9m of the following the door to a kitchen the door to a bathroom containing a tub or shower forced air ducts used for heating or cooling ceiling or whole house ventilating fans or other high air flow areas Kitch...

Страница 4: ...the fuse or circuit breaker supplying power to the alarm circuit If the alarm still does not sound the unit has defective batteries or other failure DO NOT use an open flame to test your alarm you could damage the alarm or ignite combustible materials and start a structure fire TEST THE ALARM WEEKLY TO ENSURE PROPER OPERATION Erratic or low sound coming from your alarm may indicate a defective ala...

Страница 5: ...nd check for fires first If a fire is discovered get out and call the fire department If no fire is present check to see if one of the reasons listed in Section 2 may have caused the alarm 6 MAINTENANCE ALARM REMOVAL IF TAMPER RESIST PIN HAS BEEN USED REFER TO TAMPER RESIST LOCKING PIN IN SEC TION 3 FOR PIN REMOVAL INSTRUCTIONS To replace the batteries or the lamp remove the alarm from the trim ri...

Страница 6: ...arage is normally not recommended as these locations occasionally experience condi 7 LIMITATIONS OF SMOKE ALARMS WARNING PLEASE READ CAREFULLY AND THOROUGHLY NFPA 72 states Life safety from fire in residential occupancies is based primarily on early notification to occupants of the need to escape followed by the appropriate egress actions by those occu pants Fire warning systems for dwelling units...

Страница 7: ... allow the exclusion or limitation of incidental or consequential damages the above limitations or exclu sions may not apply to you While this warranty gives you specific legal rights you may also have other rights which vary from state to state Also KIDDE Safety makes no warranty express or implied written or oral including that of mer chantability or fitness for any particular purpose with respe...

Отзывы: