Smoke Alarm

FERION 1000 O

 
 

en

 

 

Summary of Contents for F01U306021

Page 1: ...Smoke Alarm FERION 1000 O en ...

Page 2: ......

Page 3: ...le of contents 1 Graphics 4 2 Introduction 6 3 Mounting 7 4 Maintenance 9 5 Technical data 10 6 Customer Service 11 Smoke Alarm Table of Contents en 3 Bosch Sicherheitssysteme GmbH 08 15 3 1 F 01U 309 848 ...

Page 4: ...1 Graphics 1 minimum additional unsuitable 20 2 A 2 B 2 C 2 D 20 1m 1m 20 0 5 1m 0 5 1m 0 5m 0 20 4 en Graphics Smoke Alarm 08 15 3 1 F 01U 309 848 Bosch Sicherheitssysteme GmbH ...

Page 5: ...A 1 2 60 mm 5 B 1 1 1 1 A 3 1 x 3 mm 2 x 3 mm 1 4 2 s 6 7 B Smoke Alarm Graphics en 5 Bosch Sicherheitssysteme GmbH 08 15 3 1 F 01U 309 848 ...

Page 6: ...and instructions contained in this manual must be observed in order to ensure proper function The device must not be modified in any way If you have any questions about the method of operation safety or connection of the device consult the place of purchase Caution Only use original parts Only use installation materials as recommended in this manual Do not paint over the device Do not cover it wit...

Page 7: ... Find exact information about the single steps on the following pages in this manual See also the graphics at the beginning of this manual 1 Determination of mounting locations 1 Observe the information regarding Unsuitable locations for mounting page 8 and regarding Audibility page 8 Each device is to be mounted horizontally on the ceiling in centered position with a minimum distance of 0 5m to w...

Page 8: ... In the vicinity of windows ventilators air movement In the vicinity of areas where people smoke Audibility You must hear an alarm at any place in your building or flat The alarm really has to wake you up If necessary adapt the number of the devices for achieving audibility in your whole building or flat Inserting batteries Notice The detector head will only latch into the base when the batteries ...

Page 9: ...e is in normal mode no signal To perform the functional check press and release the button 2 s 6 Siren sounds 3 times 85 dB A If the functional check fails the device is defective and must be replaced Siren off alarm signal If you press and release the button 2 s of a device that has triggered an alarm then the device stops sounding After 10 min the device will switch to normal mode again Battery ...

Page 10: ...ceable batteries GASSNER LR6 FUJITSU LR6 G Dimensions diameter x height mm 119 x 50 Weight incl batteries g 168 Protection category EN60529 IP20 Operating temperature C 0 45 Storage temperature C 10 55 Relative humidity noncondensing 93 Guarantee without batteries y 5 Typical battery lifetime y 5 high temperature 30 C reduce the battery lifetime during standard usage and operation as stated in the...

Page 11: ...s EN 14604 2009 02 Signals Mode Audible Normal Functional test OK 3 x 85 db A 4 s Alarm 3 x 85 db A 4 s Weak battery 1 x short 43 s Polluted smoke chamber 3 x short 43 s 6 Customer Service Replacement of the product is only possible with proof of purchase during guarantee Smoke Alarm Graphics en 11 Bosch Sicherheitssysteme GmbH 08 15 3 1 F 01U 309 848 ...

Page 12: ... Denham Uxbridge UB 9 5HJ Tel Service 0344 7360109 E Mail boschservicecentre bosch co m Ireland Origo Ltd Unit 23 Magna Drive Magna Business Park City West Dublin 24 Tel Service 01 4666700 Fax 01 4666888 12 en Graphics Smoke Alarm 08 15 3 1 F 01U 309 848 Bosch Sicherheitssysteme GmbH ...

Page 13: ......

Page 14: ...Bosch Sicherheitssysteme GmbH Robert Bosch Ring 5 85630 Grasbrunn Germany www boschsecurity com Bosch Sicherheitssysteme GmbH 2015 ...