4. OPERATION AND TESTING

OPERATION: The smoke alarm is operating once A.C. power is applied, fresh batteries are installed and
testing is complete.  When the smoke alarm ionization chamber senses products of combustion, the
horn will sound a loud (85db) temporal alarm until the sensing chamber is cleared of smoke particles.

SAFETY LIGHT:  The model 1285 has a Safety Light feature.  When the smoke alarm ionization chamber
senses smoke, the 85 db horn will sound and the Safety Light will illuminate until the sensing chamber is
cleared of smoke particles.

NOTE: THE SAFETY LIGHT IS NOT INTENDED TO SATISFY THE REQUIREMENTS FOR
APPROVED ILLUMINATION UNDER VARIOUS LOCAL CODES.  VERY THICK AND/OR DENSE
SMOKE MAY OBSCURE THE LIGHT.

LED INDICATORS: This smoke alarm is equipped with a red and green LED indicators.  The red LED is
located under the test button and has two modes of operation.

Standby Condition

The red LED will flash every 30-40 seconds to indicate that the smoke 
alarm is operating properly.

Alarm Condition

When the alarm senses products of combustion and goes into alarm, 
the red LED will flash rapidly (one flash per second). The rapid flashing 
LED and temporal alarm will continue until the air is cleared.

WHEN UNITS ARE INTERCONNECTED, only the red LED of the alarm which senses the smoke or is
being tested (the originating unit) will flash rapidly.  All other units in the interconnect system will sound
an alarm but their red LED’s will NOT flash rapidly.

The green LED has two modes of operation.

Standby Condition

The green LED will be steady on, indicating the presence of AC power.

Alarm Memory

This smoke alarm is equipped with an alarm memory which provides a visual
indication when an alarm has been activated. A flashing green LED indicates
the memory condition. The memory will remain activated until it is reset by 
pushing the test button.

In an interconnected installation only the memory of the originating alarm will be activated.

TESTING: Test by pushing the test button on the cover and hold it down for a minimum of 2 seconds.
This will sound the alarm if the electronic circuitry and horn and battery are working. When the alarm
sounds, the Safety Light will illuminate.  If no alarm sounds,and the Safety Light does not illuminate,
check the fuse or circuit breaker supplying power to the alarm circuit.  If the alarm still does not sound,
the unit has defective batteries or other failure. DO NOT use an open flame to test your alarm, you could
damage the alarm or ignite combustible materials and start a structure fire. 

TEST THE ALARM WEEKLY TO ENSURE PROPER OPERATION. Erratic or low sound coming from your
alarm may indicate a defective alarm, and it should be returned for service (see Section 12).

5. NUISANCE ALARMS

Smoke alarms are designed to minimize nuisance alarms.  Cigarette smoke will not normally set off the
alarm, unless the smoke is blown directly into the alarm.  Combustion particles from cooking may set off
the alarm if the alarm is located close to the cooking area.  Large quantities of combustible particles are
generated from spills or when broiling.  Using the fan on a range hood which vents to the outside (non-
recirculating type) will also help remove these combustible products from the kitchen.

6. If you have finished all the WIRING, BATTERY INSTALLATION AND TRIM RING MOUNTING

STEPS, you can install the alarm on the trim ring.  Alignment marks are provided on the side of the
alarm and on the trim ring (see Figure 4).

7. Install the alarm on the trim ring with the indicating marks aligned and rotate the alarm in the

direction of the “ON” arrow on the cover until the alarm snaps in place (see Figure 4).

8. Turn on the A.C. power.  The green A.C. Power On Indicator should be lit when the alarm is

operating from A.C. power.

FIGURE 2.  SELECT CORRECT MOUNTING HOLES ON TRIM RING

TAMPER RESIST LOCKING PIN:   To make your smoke alarm somewhat tamper resistant, a locking
pin has been provided with your alarm.  Using this pin will deter children and others from removing the
alarm from trim ring.  To use the pin, insert it into the hole in the side of the alarm after the alarm has
been installed on the trim ring (see Figure 5). NOTE:  The tamper resist pin will have to be removed in
order to change the batteries.  Use a long nose pliers to pull the pin out of the hole.  It is now possible
to remove the alarm from the trim ring.

After installation, TEST your alarm by pressing and holding the test button for several seconds. This
should sound the alarm and activate the Safety Light.

Rectangular Plaster Ring

Circular Plaster Ring

Octagonal Electrical Box

To remove A.C. 
connector, 
squeeze 
locking arms 
and pull

Alignment marks

Install

Remove

Tamper resistant
locking pin

FIGURE 3.

FIGURE 4.

FIGURE 5.

Содержание 1285

Страница 1: ...n We know you expect noth ing less when the lives of your family are at stake For your convenience write down the following information If you call our Consumer Hotline these are the first questions you will be asked Smoke Alarm Model Number located on back of alarm Date Code located on back of alarm The National Fire Protection Association NFPA and the manufacturer recommends replacing this alarm...

Страница 2: ...rAdditionalProtection IonizationTypeSmokeAlarmswith Hush ControlorPhotoelectricType DIAGRAM B 3 ft 0 9m 3 ft 0 9m HORIZONTAL DISTANCE FROM PEAK ANYWHERE IN THIS AREA DIAGRAM C This product is designed to detect products of combustion using the ionization technique It contains 0 9 microcurie of Americium 241 a radioactive material Distributed under U S NRC License No 32 23858 01E Manufactured in co...

Страница 3: ...cles may cause nuisance alarms or failure to alarm In very humid areas Moisture or steam can cause nuisance alarms In insect infested areas Smoke alarms should not be installed within 3 ft 9m of the following the door to a kitchen the door to a bathroom containing a tub or shower forced air ducts used for heating or cooling ceiling or whole house ventilating fans or other high air flow areas Kitch...

Страница 4: ...the fuse or circuit breaker supplying power to the alarm circuit If the alarm still does not sound the unit has defective batteries or other failure DO NOT use an open flame to test your alarm you could damage the alarm or ignite combustible materials and start a structure fire TEST THE ALARM WEEKLY TO ENSURE PROPER OPERATION Erratic or low sound coming from your alarm may indicate a defective ala...

Страница 5: ...nd check for fires first If a fire is discovered get out and call the fire department If no fire is present check to see if one of the reasons listed in Section 2 may have caused the alarm 6 MAINTENANCE ALARM REMOVAL IF TAMPER RESIST PIN HAS BEEN USED REFER TO TAMPER RESIST LOCKING PIN IN SEC TION 3 FOR PIN REMOVAL INSTRUCTIONS To replace the batteries or the lamp remove the alarm from the trim ri...

Страница 6: ...arage is normally not recommended as these locations occasionally experience condi 7 LIMITATIONS OF SMOKE ALARMS WARNING PLEASE READ CAREFULLY AND THOROUGHLY NFPA 72 states Life safety from fire in residential occupancies is based primarily on early notification to occupants of the need to escape followed by the appropriate egress actions by those occu pants Fire warning systems for dwelling units...

Страница 7: ... allow the exclusion or limitation of incidental or consequential damages the above limitations or exclu sions may not apply to you While this warranty gives you specific legal rights you may also have other rights which vary from state to state Also KIDDE Safety makes no warranty express or implied written or oral including that of mer chantability or fitness for any particular purpose with respe...

Отзывы: