A.C. Wire-in Single and/or Multiple Station (24 Devices) Ionization Smoke
Alarm with 9 Volt Battery Back Up and Battery Powered Safety Light.

Thank you for purchasing this smoke and fire alarm.  It is an important
part of your family’s home safety plan.  You can trust this product to
provide the highest quality safety protection.  We know you expect noth-
ing less when the lives of your family are at stake.

For your convenience, write down the following information.

If you call our Consumer Hotline, these are the first questions

you will be asked.

Smoke Alarm Model Number (located on back of alarm):

Date Code (located on back of alarm).  The National Fire Protection
Association (NFPA) and the manufacturer recommends replacing this alarm
ten years from the date code:

Date of Purchase:

Where Purchased:

LISTED

AC3

Smoke and Fire Alarm

User’s Guide

For models: 1285

Содержание 1285

Страница 1: ...n We know you expect noth ing less when the lives of your family are at stake For your convenience write down the following information If you call our Consumer Hotline these are the first questions you will be asked Smoke Alarm Model Number located on back of alarm Date Code located on back of alarm The National Fire Protection Association NFPA and the manufacturer recommends replacing this alarm...

Страница 2: ...rAdditionalProtection IonizationTypeSmokeAlarmswith Hush ControlorPhotoelectricType DIAGRAM B 3 ft 0 9m 3 ft 0 9m HORIZONTAL DISTANCE FROM PEAK ANYWHERE IN THIS AREA DIAGRAM C This product is designed to detect products of combustion using the ionization technique It contains 0 9 microcurie of Americium 241 a radioactive material Distributed under U S NRC License No 32 23858 01E Manufactured in co...

Страница 3: ...cles may cause nuisance alarms or failure to alarm In very humid areas Moisture or steam can cause nuisance alarms In insect infested areas Smoke alarms should not be installed within 3 ft 9m of the following the door to a kitchen the door to a bathroom containing a tub or shower forced air ducts used for heating or cooling ceiling or whole house ventilating fans or other high air flow areas Kitch...

Страница 4: ...the fuse or circuit breaker supplying power to the alarm circuit If the alarm still does not sound the unit has defective batteries or other failure DO NOT use an open flame to test your alarm you could damage the alarm or ignite combustible materials and start a structure fire TEST THE ALARM WEEKLY TO ENSURE PROPER OPERATION Erratic or low sound coming from your alarm may indicate a defective ala...

Страница 5: ...nd check for fires first If a fire is discovered get out and call the fire department If no fire is present check to see if one of the reasons listed in Section 2 may have caused the alarm 6 MAINTENANCE ALARM REMOVAL IF TAMPER RESIST PIN HAS BEEN USED REFER TO TAMPER RESIST LOCKING PIN IN SEC TION 3 FOR PIN REMOVAL INSTRUCTIONS To replace the batteries or the lamp remove the alarm from the trim ri...

Страница 6: ...arage is normally not recommended as these locations occasionally experience condi 7 LIMITATIONS OF SMOKE ALARMS WARNING PLEASE READ CAREFULLY AND THOROUGHLY NFPA 72 states Life safety from fire in residential occupancies is based primarily on early notification to occupants of the need to escape followed by the appropriate egress actions by those occu pants Fire warning systems for dwelling units...

Страница 7: ... allow the exclusion or limitation of incidental or consequential damages the above limitations or exclu sions may not apply to you While this warranty gives you specific legal rights you may also have other rights which vary from state to state Also KIDDE Safety makes no warranty express or implied written or oral including that of mer chantability or fitness for any particular purpose with respe...

Отзывы: