Battery Removal 

NOTE:  If battery tamper resist feature has been activated
it will need to be deactivated in order to change the
battery.  Refer to the 

Battery Tamper Resist Feature

section

for instructions.

To replace or install the battery press down on the battery
door and then release to allow the door to pop open.
The battery can then be pulled out (Image 9).  When
installing a new battery, make sure the battery terminals
are facing outwards as illustrated inside the battery door
and that the polarity matches the markings printed.
Completely press the battery door down into the alarm
and release.  The battery door will secure into the closed
position.

A missing or improperly installed battery will prevent the
battery door from closing and result in improper alarm
operation.

This alarm has a low/missing battery monitor circuit which
will cause the alarm to “chirp” approximately every 30-40
seconds for a minimum of seven (7) days when the
battery gets low.  Replace the battery when this condition
occurs.

NOTE:  Low/missing battery monitor circuit WILL cause the
unit to chirp while replacing the battery.  This function will
cease once the new battery has been installed.  To avoid
this “chirp” the unit can be removed from the mounting
plate and disconnected from the AC power when re p l a c i n g
the battery, but it is not necessary.  This smoke alarm has a
convenient front-load battery feature that does not re q u i re
disconnection for changing the battery.

Testing

CAUTION:  Due to the loudness (85 decibels) of the alarm,
always stand an arms length away from the unit when testing.

Test by pushing the Test button on the cover and hold it
down for a minimum of 2 seconds.  This will sound the
alarm if all the electronic circuitry, horn and battery are
working.  If no alarm sounds, check the fuse or circuit
breaker supplying power to the alarm circuit.  If the alarm
still does not sound, the unit has a defective battery or
some other failure.  DO NOT use an open flame to test
your alarm, you could damage the alarm or ignite
combustible materials and start a fire.

Test the alarm weekly to ensure proper operation.

Erratic

or low sound coming from your alarm may indicate a
defective alarm, and it should be returned for service (see
page 25).

Alarm Removal

If the smoke alarm tamper resist feature has been
activated, refer to the 

Alarm Tamper Resist Feature

section

for removal instructions.

To remove the alarm from the mounting plate, rotate the
alarm in the direction of the "OFF" arrow on the cover. To
disconnect the AC Quick-Connect wire harness, squeeze
the locking arms on the sides of the Quick Connector
while pulling the connector away from the bottom of the
alarm (see Image 5).

M a i n t e n a n c e

Maintenance 

18

17

BATTERY DOOR OPERATION

IMAGE 9

820-0612_RevA_1276_MAN_ENG  11/17/03  9:44 AM  Page 16

Содержание 1276CA

Страница 1: ...120 V AC and 9 V Battery Backup Smoke Alarm with Test Button and Hush Control Feature Alarm Manual Model 1276CA SINGLE AND OR MULTIPLE STATION SMOKE ALARM...

Страница 2: ...ranty for service WARNING Removal of the smoke alarm battery and disconnecting or loss of AC power will render the smoke alarm inoperative ELECTRICAL RATING 120 V AC 60 HZ 80 mA maximum per alarm maxi...

Страница 3: ...iances are operated i e portable heaters or humidifiers Locate an alarm in every room where someone sleeps with the door closed The closed door may prevent the alarm from waking the sleeper Smoke heat...

Страница 4: ...ticles may cause nuisance alarms or failure to alarm Extreme temperatures may effect the sensitivity of the alarm Do not install in areas where the temperature is colder than 4 4 C 40 F or hotter than...

Страница 5: ...wer to the circuit before wiring the alarm For alarms that are used as single station DO NOT CONNECT THE RED WIRE TO ANYTHING Leave the red wire insulating cap in place to make certain that the red wi...

Страница 6: ...in Wiring attach the mounting plate to the electrical box Image 4B To ensure aesthetic alignment of the alarm with the hall way or wall the A line on the mounting plate must be parallel with the hall...

Страница 7: ...g sure that the locks on the connector snap into place Push the excess wire back into the electrical box through the hole in the center of the mounting plate Install the alarm on the mounting plate an...

Страница 8: ...ctor and locate the small cut out in the middle of the product label on the back of the unit With a small screwdriver or similar tool slide the switch towards the direction indicated by the arrows Ima...

Страница 9: ...stion are still present the alarm will sound again The Hush feature can be used repeatedly until the air has been cleared of the condition causing the alarm Pushing the Test button on the alarm will e...

Страница 10: ...the battery but it is not necessary This smoke alarm has a convenient front load battery feature that does not require disconnection for changing the battery Testing CAUTION Due to the loudness 85 de...

Страница 11: ...ed on the back of the alarm This smoke alarm uses a 9 V carbon zinc battery alkaline and lithium batteries may also be used A fresh battery should last for one year under normal operating conditions U...

Страница 12: ...nnot provide an alarm if smoke does not reach the alarm Therefore smoke alarms may not sense fires starting in chimneys walls on roofs on the other side of a closed door or on a different floor Fire S...

Страница 13: ...ly by your escape plan Every second counts so don t waste time getting dressed or picking up valuables In leaving don t open any inside door without first feeling its surface If hot or if you see smok...

Страница 14: ...modified abused or altered after the date of purchase or if it fails to operate due to improper maintenance or inadequate AC or DC electrical power The liability of Kidde or any of its parent or subsi...

Отзывы: