Hush® Control Feature

Smoke alarms are designed to minimize nuisance alarms.
Cigarette smoke will not normally set off the alarm, unless
the smoke is blown directly into the alarm.  Combustion
particles from cooking may set off the alarm if the alarm is
located close to the cooking area.  Large quantities of
combustible particles are generated from spills or when
broiling.  Using the fan on a range hood that vents to the
outside (non-recirculating type) will also help remove
these combustible particles from the kitchen.  The Hush®
button is extremely useful in a kitchen area or other areas
prone to nuisance alarms.

The Hush® feature has the capability of temporarily
desensitizing the smoke alarm circuit for about 7 minutes.
This feature is to be used only when a known alarm
condition, such as smoke from cooking, activates the
alarm.

If the alarm does sound, check for fires first.  If a fire is
discovered, get out and call the fire department.  If no fire
is present, check to see if one of the reasons listed in

Locations to Avoid

may have caused the alarm.

The smoke alarm is desensitized by pushing the Hush®
button on the smoke alarm cover.  If the smoke is not too
dense, the alarm will silence immediately 

and “chirp” every

30-40 seconds for approximately 7 minutes.

This indicates

that the alarm is in a temporarily desensitized condition.
The smoke alarm will automatically reset after
approximately 7 minutes.  If after this period particles of
combustion are still present, the alarm will sound again.  

The Hush® feature can be used repeatedly until the air
has been cleared of the condition causing the alarm.
Pushing the Test button on the alarm will end the Hush®
period.

NOTE:  Dense smoke will override the Hush® control feature
and sound a continuous alarm.

CAUTION:  Before using the alarm Hush® feature, identify the
source of the smoke and be certain a safe condition exists.

O p e r a t i o n

O p e r a t i o n

15

LED Indicators

This alarm is equipped with red and green LED indicators,
each with two modes of operation.

Red LED - Flashing eve ry 30-40 seconds:

Indicates that the

smoke alarm is operating pro p e r l y .

Red LED - Flashing Rapidly:

When the smoke alarm senses

particles of combustion and goes into alarm (constant
pulsating sound), the red LED will flash rapidly (one flash
per second).  The rapid flashing LED and pulsating alarm
will continue until the air is cleared. When interconnected,
only the red LED’s of the alarms that are sensing smoke or
are being tested will flash rapidly (originating alarms).  All
other units in the interconnect system will sound an alarm,
but their red LED’s will NOT flash rapidly.

G reen LED - Constantly On:

Indicates that the unit is

receiving 120 V AC power.

G reen LED - Flashing:

This unit features an “alarm memory”

to indicate itself as an originating alarm (that sounded and
triggered others in an interconnect system). Once the unit
returns to silence after the occurrence of an alarm, a
flashing green LED marks the unit as an originating alarm
(Image 8).  The flashing green LED remains until it is reset
by pushing the Test button.

IMAGE 8

820-0612_RevA_1276_MAN_ENG  11/17/03  9:44 AM  Page 14

Содержание 1276CA

Страница 1: ...120 V AC and 9 V Battery Backup Smoke Alarm with Test Button and Hush Control Feature Alarm Manual Model 1276CA SINGLE AND OR MULTIPLE STATION SMOKE ALARM...

Страница 2: ...ranty for service WARNING Removal of the smoke alarm battery and disconnecting or loss of AC power will render the smoke alarm inoperative ELECTRICAL RATING 120 V AC 60 HZ 80 mA maximum per alarm maxi...

Страница 3: ...iances are operated i e portable heaters or humidifiers Locate an alarm in every room where someone sleeps with the door closed The closed door may prevent the alarm from waking the sleeper Smoke heat...

Страница 4: ...ticles may cause nuisance alarms or failure to alarm Extreme temperatures may effect the sensitivity of the alarm Do not install in areas where the temperature is colder than 4 4 C 40 F or hotter than...

Страница 5: ...wer to the circuit before wiring the alarm For alarms that are used as single station DO NOT CONNECT THE RED WIRE TO ANYTHING Leave the red wire insulating cap in place to make certain that the red wi...

Страница 6: ...in Wiring attach the mounting plate to the electrical box Image 4B To ensure aesthetic alignment of the alarm with the hall way or wall the A line on the mounting plate must be parallel with the hall...

Страница 7: ...g sure that the locks on the connector snap into place Push the excess wire back into the electrical box through the hole in the center of the mounting plate Install the alarm on the mounting plate an...

Страница 8: ...ctor and locate the small cut out in the middle of the product label on the back of the unit With a small screwdriver or similar tool slide the switch towards the direction indicated by the arrows Ima...

Страница 9: ...stion are still present the alarm will sound again The Hush feature can be used repeatedly until the air has been cleared of the condition causing the alarm Pushing the Test button on the alarm will e...

Страница 10: ...the battery but it is not necessary This smoke alarm has a convenient front load battery feature that does not require disconnection for changing the battery Testing CAUTION Due to the loudness 85 de...

Страница 11: ...ed on the back of the alarm This smoke alarm uses a 9 V carbon zinc battery alkaline and lithium batteries may also be used A fresh battery should last for one year under normal operating conditions U...

Страница 12: ...nnot provide an alarm if smoke does not reach the alarm Therefore smoke alarms may not sense fires starting in chimneys walls on roofs on the other side of a closed door or on a different floor Fire S...

Страница 13: ...ly by your escape plan Every second counts so don t waste time getting dressed or picking up valuables In leaving don t open any inside door without first feeling its surface If hot or if you see smok...

Страница 14: ...modified abused or altered after the date of purchase or if it fails to operate due to improper maintenance or inadequate AC or DC electrical power The liability of Kidde or any of its parent or subsi...

Отзывы: