120 V  AC  and 9 V Battery Backup

S

moke 

A

larm

with Test Button and Hush

®

Control Feature

A l a rm Manual

Model 1276CA

SINGLE AND/OR MULTIPLE STATION

SMOKE ALARM

820-0612_RevA_1276_MAN_ENG  11/17/03  9:44 AM  Page 1

Содержание 1276CA

Страница 1: ...120 V AC and 9 V Battery Backup Smoke Alarm with Test Button and Hush Control Feature Alarm Manual Model 1276CA SINGLE AND OR MULTIPLE STATION SMOKE ALARM...

Страница 2: ...ranty for service WARNING Removal of the smoke alarm battery and disconnecting or loss of AC power will render the smoke alarm inoperative ELECTRICAL RATING 120 V AC 60 HZ 80 mA maximum per alarm maxi...

Страница 3: ...iances are operated i e portable heaters or humidifiers Locate an alarm in every room where someone sleeps with the door closed The closed door may prevent the alarm from waking the sleeper Smoke heat...

Страница 4: ...ticles may cause nuisance alarms or failure to alarm Extreme temperatures may effect the sensitivity of the alarm Do not install in areas where the temperature is colder than 4 4 C 40 F or hotter than...

Страница 5: ...wer to the circuit before wiring the alarm For alarms that are used as single station DO NOT CONNECT THE RED WIRE TO ANYTHING Leave the red wire insulating cap in place to make certain that the red wi...

Страница 6: ...in Wiring attach the mounting plate to the electrical box Image 4B To ensure aesthetic alignment of the alarm with the hall way or wall the A line on the mounting plate must be parallel with the hall...

Страница 7: ...g sure that the locks on the connector snap into place Push the excess wire back into the electrical box through the hole in the center of the mounting plate Install the alarm on the mounting plate an...

Страница 8: ...ctor and locate the small cut out in the middle of the product label on the back of the unit With a small screwdriver or similar tool slide the switch towards the direction indicated by the arrows Ima...

Страница 9: ...stion are still present the alarm will sound again The Hush feature can be used repeatedly until the air has been cleared of the condition causing the alarm Pushing the Test button on the alarm will e...

Страница 10: ...the battery but it is not necessary This smoke alarm has a convenient front load battery feature that does not require disconnection for changing the battery Testing CAUTION Due to the loudness 85 de...

Страница 11: ...ed on the back of the alarm This smoke alarm uses a 9 V carbon zinc battery alkaline and lithium batteries may also be used A fresh battery should last for one year under normal operating conditions U...

Страница 12: ...nnot provide an alarm if smoke does not reach the alarm Therefore smoke alarms may not sense fires starting in chimneys walls on roofs on the other side of a closed door or on a different floor Fire S...

Страница 13: ...ly by your escape plan Every second counts so don t waste time getting dressed or picking up valuables In leaving don t open any inside door without first feeling its surface If hot or if you see smok...

Страница 14: ...modified abused or altered after the date of purchase or if it fails to operate due to improper maintenance or inadequate AC or DC electrical power The liability of Kidde or any of its parent or subsi...