![KIC start Скачать руководство пользователя страница 44](http://html1.mh-extra.com/html/kic/start/start_user-manual_1963758044.webp)
KICstart
Version
1.1.0.x
KICstart User Manual
37
Profile Graph Display
Once the
KICstart
software
opens the
Profile Graph
Display
, the tabs at the top
will be accessible. The
General
Tab will show the
profile results for preheat and
wave sections of the profile.
You can select either the
Preheat tab or the Wave tab
above the
Statistic
table.
Preheat tab
The
Preheat
tab represents
only the section of the profile
before the wave. The
KICstart
software draws a
Blue rectangle around the
area that represents the
preheat
area.
Th
e profile
Statistics
and setpoints which
are shown below the profile
graph depict only the
preheat
section of the profile, the
profile data inside the Blue rectangle.
Information regarding the
Wave TCs
is displayed in a window at the upper-Right hand corner of the profile
graph. This information includes; Dwell time, parallelism, and the solder temperatures for the wave(s).
Wave Tab
The
Wave
Tab will show profile information specific to the wave portion
of the profile. The
KICstart
software draws a Blue rectangle around the
area that represents the
Wave
area. The profile
Statistics
and setpoints
which are shown below the profile graph depict only the
Wave
section of
the profile.
Profile Information from the
Wave TCs
is displayed in a window at the
upper-Right hand corner of the profile graph. This information includes;
Dwell time and Parallelism in seconds, and the solder temperature
setpoint and actual for the
wave(s
) portion of the profile.
The Dwell time is measured by the
Wave TCs.
The Parallelism is the measured time difference between
when the
Wave TC
-Left, and
Wave TC
-Right hit the wave.
The Solder Temperature setpoint is input by the user before the profile when entering oven setpoint
information. The solder temperature value is measured by the
Air TC
during the profile.
Statistics
- Below the profile graph is the
Profile Statistics
. The
Statistics
are a numeric representation of
the profile and how well the profile fits the selected
Process Window
. The
Statistics
for this profile and the
predicted profile are shown. A percentage value is displayed in each cell beside the
Statistic
value. This
percentage represents the amount of
Process Window
being used. A
PWI
under 100% indicate the profile
fits within the selected
Process Window
, a
PWI
100%or higher indicates the profile has exceeded the
selected
Process Window
. The
KICstart
software will only display
PWI
values for the
Preheat Statistics
.
Original Setpoints -
Below the profile
Statistics
is the oven temperature and conveyor settings. The
original
setpoints represent the oven settings when this profile was run.
The F9 function key will print any active profile screen of the KICstart software.