![KIC start Скачать руководство пользователя страница 26](http://html1.mh-extra.com/html/kic/start/start_user-manual_1963758026.webp)
KICstart
Version
1.1.0.x
KICstart User Manual
19
KICstart Temperature Triggers
The
KICstart
software uses temperature triggers for the
KICstart
profiler to determine when the profile is
started, and when it ends. The use of temperature triggers makes it so that the user does not have to worry
about starting the profile a specific point or time. Instead the profile is started at the same temperature and
ends at the same temperature each time you profile, making the profile data collection process consistent.
The default temperature triggers are as follows for each respective
Application
type:
Wave Solder-Wave On
Profile start
33ºC/92ºF
Mid trigger
110ºC/230ºF
Profile end
90ºC/194ºF
The default trigger values should be fine for most processes. The Profile start-trigger is determined by the
Maximum Product Temperature at Start of Profile
setting in the
Global Preferences
screen. The start
trigger value is always 2ºC above this value.
In the event that the mid-trigger, or end trigger values need to be changed, or you feel that you are
experiencing a problem related to temperature triggers please contact
KIC
Technical support,
KICstart Profile Download
While the KIC
start
profiler is profiling, it stores the profile data in its on board memory. Once the
KIC
start
detects that all of the thermocouples have cooled below the profile-end trigger value, it will begin
downloading the profile data. Connect the
KICstart
communication cable to the
KICstart
and the
download will begin automatically.
The KICstart profiler will be hot to the touch. Use gloves if necessary to avoid burn injuries while
connecting the communication cable.
When downloading begins, the
KICstart
will send the profile in data packets. The downloading status is
displayed at the bottom of the profile screen.
When all of the data packets have been received, the software will display a message asking you to turn the
KICstart
off, choose OK. Failing to turn the
KICstart
off will drain the battery.
Next, the
KICstart
software will present the profile and statistics.
Wave Solder-Wave Off
Profile start
33ºC/92ºF
Mid trigger
130C/266F
Profile end
110C/230F
Semiconductor
Profile start
33ºC/92ºF
Mid trigger
130
º
C/266
º
F
Profile end
110
º
C/230
º
F
Solder Reflow
Profile start
33ºC/92ºF
Mid trigger
130
º
C/266
º
F
Profile end
110
º
C/230
º
F
Cure
Profile start
33ºC/92ºF
Mid trigger
100
º
C/212
º
F
Profile end
80
º
C/176
º
F
Содержание start
Страница 1: ...KICstart User Manual Hardware and Software Version 1 1 0 x ...
Страница 2: ......
Страница 3: ......
Страница 16: ...KICstart Version 1 1 0 x KICstart User Manual 9 ...